{"product_id":"um33a-000-11-process-monitor-yokogawa-utadvanced-1-8-din-indicator","title":"UM33A-000-11 Process Monitor | Yokogawa UTAdvanced 1\/8 DIN Indicator","description":"\u003ch3\u003e\u003cstrong\u003eEngineering Summary \u0026amp; Operational Role\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eYokogawa UM33A-000-11\u003c\/strong\u003e is a compact 1\/8 DIN digital process indicator engineered within the \u003cstrong style=\"color: #0056b3;\"\u003eUTAdvanced\u003c\/strong\u003e series. It continuously monitors critical industrial parameters including temperature, pressure, and volumetric flow rates. Featuring a high-contrast 14-segment active color LCD, the unit transitions process value digits from white to red during alarm events for immediate operator recognition on dense control panels.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eModel Suffix \u0026amp; Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBase Model: \u003cspan style=\"color: #0056b3;\"\u003eUM33A\u003c\/span\u003e\u003c\/strong\u003e — 1\/8 DIN Digital Indicator with Alarm Functions\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eBasic Code (-0):\u003c\/strong\u003e Standard type configuration (100–240 V AC power supply)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eAdditional Functions (0):\u003c\/strong\u003e None (Base hardware specification)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eOpen Networks (0):\u003c\/strong\u003e None (Standalone local indication and alarm control)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eDisplay Language (-1):\u003c\/strong\u003e English default menu guide (User-switchable to German, French, or Spanish)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eCase Color (1):\u003c\/strong\u003e Black \/ Light charcoal gray polycarbonate housing\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Architecture \u0026amp; I\/O Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003e\u003cstrong\u003eSubsystem\u003c\/strong\u003e\u003c\/th\u003e\n      \u003cth\u003e\u003cstrong\u003eEngineering Parameter\u003c\/strong\u003e\u003c\/th\u003e\n      \u003cth\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIdentification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eManufacturer \u0026amp; Model\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003eYokogawa Electric\u003c\/strong\u003e \/ \u003cstrong style=\"color: #0056b3;\"\u003eUM33A-000-11\u003c\/strong\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUniversal Channel \u0026amp; Scan Rate\u003c\/td\u003e\n      \u003ctd\u003e1 channel (Thermocouple, RTD, DC V\/mA); 50 to 200 ms sampling period\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDiscrete Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eContact Inputs\u003c\/td\u003e\n      \u003ctd\u003e2 points (No-voltage contact or transistor contact input)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAlarm Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eContact Configuration\u003c\/td\u003e\n      \u003ctd\u003eAlarm-1 to -3: 1a contact (3 points, independent common); Alarm-4: 1c contact (1 point)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRetransmission \u0026amp; Loop Power\u003c\/td\u003e\n      \u003ctd\u003e1 point (4–20 mA or 0–20 mA DC, ≤ 600 Ω load), shared with 15 V DC loop supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDisplay Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eReadout \u0026amp; Bargraph\u003c\/td\u003e\n      \u003ctd\u003e5-digit, 14-segment active color LCD (White\/Red PV; Orange data\/bargraph)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower \u0026amp; Wiring\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSupply \u0026amp; Terminals\u003c\/td\u003e\n      \u003ctd\u003e100–240 V AC standard; M3 screw terminals with square washers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMechanical \u0026amp; Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEnclosure \u0026amp; Dimensions\u003c\/td\u003e\n      \u003ctd\u003e96 × 48 × 65 mm (Cutout: 92 × 45 mm); 0.5 kg; IP66 \/ NEMA4 front; UL94V-0 polycarbonate\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePanel Integration \u0026amp; Mounting Constraints\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCut a precise 92 mm (W) × 45 mm (H) rectangular opening in the control cabinet door to maintain the IP66 front seal.\u003c\/li\u003e\n  \u003cli\u003eMaintain a shallow rear clearance of 65 mm behind the panel face, allowing extra space for terminal lug bending radii.\u003c\/li\u003e\n  \u003cli\u003eInstall the \u003cstrong style=\"color: #0056b3;\"\u003eUM33A-000-11\u003c\/strong\u003e horizontally or tilted upward up to 30 degrees maximum; downward tilting is strictly prohibited to prevent heat accumulation.\u003c\/li\u003e\n  \u003cli\u003eTerminate all signal and 100–240 V AC power leads onto the M3 screw terminals using ring or fork lugs suited for square washers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSupply Chain, Warranty \u0026amp; Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty Coverage:\u003c\/strong\u003e Backed by a comprehensive 12-month operational warranty against manufacturing and functional defects.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlobal Dispatch:\u003c\/strong\u003e Rapid international fulfillment via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, and \u003cstrong\u003eDHL\u003c\/strong\u003e express air freight with full tracking visibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQ \u0026amp; Selection Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the shared retransmission and loop power output affect two-wire transmitter wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \u003cspan style=\"color: #0056b3;\"\u003eUM33A-000-11\u003c\/span\u003e shares its single analog output hardware between 4–20 mA retransmission and the 15 V DC sensor power supply. If your field transmitter requires internal loop excitation from this unit, you cannot simultaneously use the analog retransmission signal to feed a downstream PLC.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Why does the specification list two discrete contact inputs alongside the universal analog input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Those two no-voltage or transistor contact inputs allow operators to trigger remote functions such as peak\/bottom hold resets, alarm latch clearances, or display mode switching directly from external panel pushbuttons.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I add RS-485 Modbus communication to this specific part number later?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The middle zeros in \u003cspan style=\"color: #0056b3;\"\u003eUM33A-000-11\u003c\/span\u003e indicate that open network and communication hardware boards are omitted at the factory. If your architecture requires Modbus\/RTU or CC-Link integration, specify a different suffix code prior to ordering.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What makes the Alarm-4 output different from Alarms 1 through 3 during safety interlock wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Alarms 1, 2, and 3 provide Form-A (1a) normally open contacts with independent commons, whereas Alarm-4 offers a Form-C (1c) changeover contact, making Alarm-4 ideal for fail-safe de-energize-to-trip annunciator circuits.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How should engineers select between the 50 ms and 200 ms sampling periods during commissioning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Use the 50 ms fast scan rate for rapid pressure spikes or dynamic flow monitoring, and select 200 ms for slow thermal loops to maximize 50\/60 Hz power-line noise rejection.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":68048284582070,"sku":"UM33A-000-11","price":195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/UM33A-000-11-1.jpg?v=1794465538","url":"https:\/\/www.plcsparehub.com\/products\/um33a-000-11-process-monitor-yokogawa-utadvanced-1-8-din-indicator","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}