{"product_id":"tr3102-e05-g01-s00-provibtech-proximity-3-wire-transmitter-in-stock","title":"TR3102-E05-G01-S00 ProvibTech Proximity 3-Wire Transmitter In Stock","description":"\u003ch3\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eEngineering Overview: TR3102 Axial Position Transmitter Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTR3102\u003c\/strong\u003e\u003c\/span\u003e (Model: \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTR3102-E05-G01-S00\u003c\/strong\u003e\u003c\/span\u003e) is an integrated 3-wire proximity transmitter manufactured by \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eProvibTech\u003c\/strong\u003e\u003c\/span\u003e for continuous axial position tracking and phase reference monitoring on balance-of-plant rotating machinery.\u003c\/p\u003e\n\u003cp\u003eBy housing the eddy-current proximity probe driver and signal conditioning circuitry within a single copper-free cast aluminum enclosure with epoxy potting, the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTR3102\u003c\/strong\u003e\u003c\/span\u003e eliminates the requirement for a separate external proximitor driver unit.\u003c\/p\u003e\n\u003cp\u003eThis compact device connects directly to standard 5mm, 8mm, or 11mm eddy current probes and extension cables, converting physical target displacement into a proportional 4-20 mA current loop output compatible with host DCS or PLC automation controllers.\u003c\/p\u003e\n\u003cp\u003eA buffered raw voltage output (GAP V) allows long-distance signal transmission up to 300 meters (1,000 feet) for field analysis and portable diagnostic instruments.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eOrdering Code \u0026amp; Configuration Breakdown: TR3102-E05-G01-S00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBase Part Number Structure: TR3102-EXX-GXX-SXX\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTR3102:\u003c\/strong\u003e Base Model - Proximity 3-Wire Axial Position \u0026amp; Phase Reference Transmitter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE05 (Probe \u0026amp; Cable Options):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eConfigured for 7200 Series, 8mm Eddy Current Probes\u003c\/li\u003e\n\u003cli\u003eCalibrated System Cable Length: 9 Meters (Probe + Extension Cable)\u003c\/li\u003e\n\u003cli\u003eAlternative System Options (Reference): E00 (5m\/8mm), E01 (9m\/5mm), E02 (5m\/11mm), etc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG01 (Mounting \u0026amp; Functional Code):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMounting Configuration: Plate Mount Enclosure\u003c\/li\u003e\n\u003cli\u003eMeasurement Target: Thrust \/ Axial Position Signal Conditioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS00 (Agency Approval Code):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eCertification Standard: CE Mark (Factory Default Compliance)\u003c\/li\u003e\n\u003cli\u003eTR CU Certification Reference: № ТС RU C-US.ГБ05.В.00479\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTechnical Parameter Matrix\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical \u0026amp; Loop Power Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \/ Manufacturer:\u003c\/strong\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eProvibTech\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTR3102\u003c\/strong\u003e\u003c\/span\u003e (\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTR3102-E05-G01-S00\u003c\/strong\u003e\u003c\/span\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Range:\u003c\/strong\u003e 20 to 30 VDC (Powered via DCS\/PLC current loop)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Output:\u003c\/strong\u003e 2-wire sourcing 4-20 mA proportional to shaft axial position\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Loop Resistance:\u003c\/strong\u003e 500 Ohms @ 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuffered Raw Output (GAP V):\u003c\/strong\u003e Nominal 2 to 18 VDC raw position signal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuffered Output Impedance:\u003c\/strong\u003e 1,000 Ohms (Drives signals up to 300 meters \/ 1,000 feet)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Compatibility \u0026amp; Measurement Dynamics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoaxial Interface:\u003c\/strong\u003e Special 95 Ω coaxial female connector assembly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Probes:\u003c\/strong\u003e 5mm, 8mm, and 11mm probes (ProvibTech TM0180, TM0105, TM0110; Bently Nevada 3300, 7200, 990 series)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Range (8mm Probe):\u003c\/strong\u003e 2.0 mm (80 mils), spanning ~0.25 mm (10 mils) to 2.25 mm (90 mils) against AISI 4140 steel target\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Range (11mm Probe):\u003c\/strong\u003e 4.0 mm (160 mils), spanning ~0.4 mm (15 mils) to 4.4 mm (175 mils)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Sensitivity:\u003c\/strong\u003e 8.0 mV\/μm (200 mV\/mil)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response Bandwidth:\u003c\/strong\u003e 0 Hz to 10 kHz (DC static displacement capable)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Material:\u003c\/strong\u003e Die-cast copper-free aluminum with internal protective epoxy potting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Dimensions:\u003c\/strong\u003e Total Height: 75 mm (2.95 inches)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Weight:\u003c\/strong\u003e 1.0 kg (2.0 lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range:\u003c\/strong\u003e -40°C to +100°C (-40°F to +212°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermissible Relative Humidity:\u003c\/strong\u003e Up to 90% relative humidity (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTarget Applications \u0026amp; Compatible Machinery\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCentrifugal Pumps \u0026amp; Compressors:\u003c\/strong\u003e Tracking rotor shaft axial float to prevent impeller-to-casing mechanical contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBalance-of-Plant Steam Turbines:\u003c\/strong\u003e Continuous thrust bearing wear monitoring and phase reference (Keyphasor) detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Gearboxes \u0026amp; Blowers:\u003c\/strong\u003e Measuring axial displacement on high-speed shaft assemblies under thermal expansion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-Vendor System Retrofits:\u003c\/strong\u003e Direct replacement of legacy proximitor drivers connecting existing 7200 or 3300 series probes to modern PLC analog inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSelf-Test Diagnostics \u0026amp; Signal Troubleshooting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Health Monitoring:\u003c\/strong\u003e Normal operation outputs a standard 4-20 mA current proportional to position within the linear range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Not OK State:\u003c\/strong\u003e If probe cable severance, shorted coaxial connectors, or internal sensor failure occurs, current drops below 3.0 mA to alert the host controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGAP Voltage Field Verification:\u003c\/strong\u003e Connect a high-impedance digital multimeter to the GAP V terminals; a reading between 2 VDC and 18 VDC confirms valid probe standoff spacing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoaxial Interface Integrity:\u003c\/strong\u003e Inspect the 95 Ω coaxial connector for oil ingress or loose center pins when GAP voltage reads out-of-range (\u0026gt;18V or \u0026lt;2V).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eDuring an emergency vibration survey at a boiler feed water pumping station, plant operators reported erratic 4-20 mA axial position spikes coming from a newly wired \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTR3102-E05-G01-S00\u003c\/strong\u003e\u003c\/span\u003e module. The PLC was logging transient high-thrust alarms during pump startup. Our engineering team reviewed the installation and discovered that while an 8mm probe was installed, technicians had wired it using an uncalibrated 5-meter total cable length instead of the mandatory 9-meter system length required by the E05 configuration code. The impedance mismatch shifted the oscillator frequency and ruined linear scaling. Once we installed the correct 9-meter extension cable assembly to match the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTR3102\u003c\/strong\u003e\u003c\/span\u003e calibration, the GAP voltage stabilized at 10.2 VDC (centered in the 80-mil linear window), and the 4-20 mA output accurately tracked shaft float without further false trips.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eLogistics, Shipping, and Warranty Terms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpress Global Logistics:\u003c\/strong\u003e Fast dispatch via international express couriers including FedEx, DHL, and UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarehouse Handling Time:\u003c\/strong\u003e Orders are processed and shipped within 24 to 48 hours following payment receipt.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Packaging:\u003c\/strong\u003e Unit is packed in ESD-shielded anti-static wrap and cushioned in high-density foam within an industrial carton.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Protection:\u003c\/strong\u003e Standard 12-month operational replacement warranty included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eEngineering Selection \u0026amp; Procurement Guide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen selecting a \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTR3102\u003c\/strong\u003e\u003c\/span\u003e transmitter, match the ordering suffix (E Code) precisely to your installed eddy current probe model and total system cable length (probe + extension cable = 5m or 9m).\u003c\/p\u003e\n\u003cp\u003eFor radial shaft vibration monitoring instead of axial position or phase speed reference, evaluate the companion TR3101 dynamic vibration transmitter series.\u003c\/p\u003e\n\u003cp\u003eEnsure the target shaft material matches standard AISI 4140 alloy steel calibration; non-magnetic or stainless steel targets require custom factory calibration factors.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eField Engineering Frequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e What is the physical difference between the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTR3102\u003c\/strong\u003e\u003c\/span\u003e transmitter and a standard Bently Nevada proximitor driver?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Standard proximitor drivers output a raw AC\/DC millivolt signal requiring a dedicated monitoring rack, whereas the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTR3102\u003c\/strong\u003e\u003c\/span\u003e houses both the driver and signal conditioner in one unit to output a direct 4-20 mA DC signal into a standard PLC analog input.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e How do I mechanical set zero axial position using the GAP V reading during installation?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Mechanically adjust probe insertion depth until the GAP voltage output reads approximately 10.0 VDC (center of the 2-18 VDC linear curve) when the shaft is set to its mechanical center float position.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e Can I extend the coaxial cable between the probe and the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTR3102-E05-G01-S00\u003c\/strong\u003e\u003c\/span\u003e transmitter past 9 meters?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e No, changing coaxial cable length alters system inductance and capacitance, destroying measurement accuracy; total cable length between probe tip and transmitter terminals must match the 9-meter specification exactly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e What does an output current reading of 2.5 mA indicate to the control room?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e A current reading below 3.0 mA signifies a \"System Not OK\" condition, usually caused by a damaged probe tip, disconnected coaxial cable, or loss of primary loop power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e Is an external barrier required when installing the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTR3102\u003c\/strong\u003e\u003c\/span\u003e in hazardous environments?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e The standard S00 option carries factory CE approvals for general safe areas; applications in hazardous areas require ordering hazardous-rated approvals (such as EX options) along with certified galvanic isolators or zener barriers.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/TR3102.png?v=1788249848\" alt=\"\"\u003e\u003c\/p\u003e","brand":"ProvibTech","offers":[{"title":"Default Title","offer_id":45397133197494,"sku":"TR3102-E05-G01-S00","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/TR4101-A02-E01-G00-S01_5249b151-30b4-4e34-bdf3-d014a391c9d1.jpg?v=1788249902","url":"https:\/\/www.plcsparehub.com\/products\/tr3102-e05-g01-s00-provibtech-proximity-3-wire-transmitter-in-stock","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}