{"product_id":"tm5sdo4r-modicon-tm5-relay-module-schneider-electric-discrete-output","title":"TM5SDO4R Modicon TM5 Relay Module Schneider Electric Discrete Output","description":"\u003ch3\u003e\n\u003cstrong\u003eTM5SDO4R\u003c\/strong\u003e Architectural Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eTM5SDO4R\u003c\/span\u003e\u003c\/strong\u003e is a high-capacity discrete relay output module developed for the modular \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eModicon TM5\u003c\/span\u003e\u003c\/strong\u003e IP20 distributed I\/O system. Featuring four isolated electromechanical channels, this compact slice module delivers robust physical switching capabilities up to 5 A per channel. It acts as an optimal barrier between high-current field equipment and the low-voltage logic bus. The engineering design integrates full reverse polarity protection on its internal bus links to safeguard system operations. This hardware provides versatile application compatibility, handling both high-voltage AC utility distributions and low-voltage DC lines efficiently.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eTM5SDO4R\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eModicon TM5\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e Discrete Relay Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Digital Outputs:\u003c\/strong\u003e 4 Channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Configuration:\u003c\/strong\u003e 4 Normally Open (4 NO) Contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Switched AC Voltage:\u003c\/strong\u003e 230 V AC (Absolute Voltage Limits: 184 to 276 V AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Switched DC Voltage:\u003c\/strong\u003e 30 V DC (Absolute Voltage Limits: 24 to 36 V DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Continuous Current:\u003c\/strong\u003e 5 A Per Channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Total Commutated Current:\u003c\/strong\u003e 10 A Total Per Output Common Link\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Switching Response Time:\u003c\/strong\u003e Less than 10 ms for both State Changes (0 to 1 and 1 to 0)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation Rating:\u003c\/strong\u003e 500 Vrms AC Isolation between the I\/O Channel and Internal Bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInter-Channel Insulation:\u003c\/strong\u003e No isolation barrier between individual adjacent channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnboard Power Dissipation:\u003c\/strong\u003e 2.3 W Maximum Thermal Emission under Peak Switching Conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Current Consumption:\u003c\/strong\u003e 160 mA Drawn from the 5 V DC Rack Power Bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Housing Color:\u003c\/strong\u003e Black Industrial Polymer Shell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Hardware Weight:\u003c\/strong\u003e 0.025 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical \u0026amp; Electrical Lifespan Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Lifespan Performance:\u003c\/strong\u003e 20,000,000 Total Mechanical Switching Sequences\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Contact Lifespan:\u003c\/strong\u003e 500,000 Full-Load Operations at 5 A Switching Thresholds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Limits \u0026amp; Stress Tolerances\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontal Layout Operation Temperature:\u003c\/strong\u003e -10 to 55 Degrees Celsius without thermal derating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontal Layout Maximum Limit:\u003c\/strong\u003e -10 to 60 Degrees Celsius utilizing factory derating curves\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVertical Layout Operation Temperature:\u003c\/strong\u003e -10 to 50 Degrees Celsius Maximum Limits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Term Storage Environment:\u003c\/strong\u003e -40 to 70 Degrees Celsius Ambient Range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Operating Humidity:\u003c\/strong\u003e 5% to 95% Non-condensing Atmospheric Conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Geometric Altitude:\u003c\/strong\u003e 0 to 2000 Meters Above Sea Level\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Storage Elevation:\u003c\/strong\u003e 0 to 3000 Meters Static Atmospheric Limits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection Level:\u003c\/strong\u003e IP20 Certified Conformant to IEC 61131-2 Standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAtmospheric Contamination Level:\u003c\/strong\u003e Pollution Degree 2 Certified to IEC 60664 Standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectromagnetic \u0026amp; Structural Resiliency Profile\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStructural Vibration Limits:\u003c\/strong\u003e 1 gn Acceleration at 8.4 to 150 Hz \/ 3.5 mm Amplitude at 5 to 8.4 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Shock Resistance:\u003c\/strong\u003e 15 gn Mechanical Shocks Sustained for 11 Milliseconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge Resiliency:\u003c\/strong\u003e 4 kV Contact Discharges \/ 8 kV Air Discharges (IEC 61000-4-2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiated RF Immunity (High Frequency):\u003c\/strong\u003e 1 V\/m Field Strength at 2 to 2.7 GHz Spectrum (IEC 61000-4-3)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiated RF Immunity (Standard Range):\u003c\/strong\u003e 10 V\/m Field Strength at 80 to 2000 MHz Spectrum (IEC 61000-4-3)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Fast Transient \/ Burst Resiliency:\u003c\/strong\u003e 1 kV I\/O Links \/ 1 kV Shielded Paths \/ 2 kV Power Infrastructure (IEC 61000-4-4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Energy Surge Wave Immunity:\u003c\/strong\u003e 0.5 kV Differential Mode Paths \/ 1 kV Common Mode Paths (IEC 61000-4-5)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Integration \u0026amp; Target Platforms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotion Control Platform Support:\u003c\/strong\u003e PacDrive LMC Motion Controller System Architectures\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated CPU Compatibility Node:\u003c\/strong\u003e PacDrive LMC Pro 2 Engine Layouts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact CPU Compatibility Node:\u003c\/strong\u003e PacDrive LMC Eco Processing Frameworks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Performance CPU Compatibility Node:\u003c\/strong\u003e PacDrive LMC Pro Automation Platforms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Base Requirements:\u003c\/strong\u003e Integrates into matching TM5 slice bases with standard DIN rail installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect interface to pilot duty inductive coils, main line contactors, and high-amp industrial solenoids.\u003c\/li\u003e\n\u003cli\u003ePower supply switching circuits for distributed control system indicators and audible alarm devices.\u003c\/li\u003e\n\u003cli\u003eMulti-axis coordinated motion control panels handling heavy electromechanical safety interlocks.\u003c\/li\u003e\n\u003cli\u003eDecentralized packaging machinery networks requiring rugged relay interfaces outside the main panel.\u003c\/li\u003e\n\u003cli\u003eMaterial handling conveyor lines demanding reliable switching of localized AC motorized actuators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostic \u0026amp; System Safety Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReverse Polarity Protection:\u003c\/strong\u003e Integrated hardware mechanisms safeguard inner logic routing against incorrect power connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Communication Diagnosis:\u003c\/strong\u003e The upstream master controller detects internal slice fault flags when data transmission fails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnboard LED Array:\u003c\/strong\u003e High-visibility indicators display clear physical output status for quick signal pathway verification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance \u0026amp; Standards Registry\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEuropean Community CE Directives Compliance\u003c\/li\u003e\n\u003cli\u003eSafety Evaluation for Industrial Control Equipment UL 508\u003c\/li\u003e\n\u003cli\u003eSafety Evaluation for Industrial Control Systems CSA C22.2 No 142\u003c\/li\u003e\n\u003cli\u003eHazardous Location Operations Certification CSA C22.2 No 213 Class I Division 2\u003c\/li\u003e\n\u003cli\u003eGeneral Requirements for Programmable Controllers IEC 61131-2\u003c\/li\u003e\n\u003cli\u003eElectromagnetic Emissions Compliance Matrix CISPR 11 \/ Conducted RF Disturbances IEC 61000-4-6\u003c\/li\u003e\n\u003cli\u003eInternational Regulatory Marks: cULus Listed, GOST-R, C-Tick\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne New \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eSchneider Electric TM5SDO4R\u003c\/span\u003e\u003c\/strong\u003e Discrete Relay Slice Module\u003c\/li\u003e\n\u003cli\u003eFactory-Printed Reference Documentation Sheet\u003c\/li\u003e\n\u003cli\u003e12-Month Comprehensive Warranty Coverage against material defects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping Logistics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCourier Distribution:\u003c\/strong\u003e Express door-to-door transit via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Timeline:\u003c\/strong\u003e Worldwide dispatch procedures conclude within 24 to 48 hours of order verification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eTM5SDO4R\u003c\/span\u003e\u003c\/strong\u003e is a premium, space-saving solution designed for dense decentralized automation topologies. While standard electronic output modules limit you to minimal current thresholds, this electromechanical relay slice delivers a hefty 5 A switching capacity across individual terminals. This eliminates the cost and space required for external interposing relays in crowded control panels. System designers must note that this slice lacks onboard short-circuit or overload protection circuits. To prevent contact welding under peak inductive loads, you must implement external circuit breakers or high-speed fusing networks into your cabinet drawings.\u003c\/p\u003e\n\u003ch3\u003eProcurement Selection Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChoose this module when you require high-current capacity switching without upgrading to bulky standard chassis formats.\u003c\/li\u003e\n\u003cli\u003eFactor in the horizontal vs. vertical mounting position since vertical mounting drops the maximum thermal threshold to 50 Degrees Celsius.\u003c\/li\u003e\n\u003cli\u003eCombine this module with standard TM5 digital and analog components to form a unified, custom I\/O drops layout.\u003c\/li\u003e\n\u003cli\u003eVerify the total power consumption on the 5 V DC TM5 bus before installation to ensure your power distribution module has adequate current head room.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch3\u003eWhat happens if the maximum current across a shared output common exceeding 10 A?\u003c\/h3\u003e\n\u003cp\u003eExceeding the 10 A total limit across the common terminal causes internal trace overheating and material fatigue. This can lead to permanent board damage and catastrophic hardware failure before the fuses can trip.\u003c\/p\u003e\n\u003ch3\u003eCan I install this module into an environment subject to persistent freezing conditions?\u003c\/h3\u003e\n\u003cp\u003eNo. The operational temperature window begins strictly at -10 Degrees Celsius. Operating the module below this limit can freeze internal relay mechanisms, causing severe switching delays or complete failure.\u003c\/p\u003e\n\u003ch3\u003eWhy is external surge protection explicitly recommended for this relay slice?\u003c\/h3\u003e\n\u003cp\u003eThe module lacks onboard transient voltage suppression. When driving highly inductive elements, the back-EMF arc will pit the internal contacts, which rapidly degrades the electrical lifespan well below the 500,000 cycle rating.\u003c\/p\u003e\n\u003ch3\u003eIs it possible to swap this module from the DIN rail base during active system runtime?\u003c\/h3\u003e\n\u003cp\u003eHot-swapping depends on the configuration of your specific Modicon TM5 bus base. While the mechanical design supports slide-out removal, you must verify that your controller software is configured to handle hot-swap drops without causing an unexpected system stop.\u003c\/p\u003e\n\u003ch3\u003eDoes this module support high-frequency pulse output modulation for proportional valve control?\u003c\/h3\u003e\n\u003cp\u003eNo. Electromechanical relays are limited by a combined 20 ms mechanical cycle response time. High-frequency pulsing will cause rapid contact wear and premature component failure. For fast-cycling adjustments, choose transistor-based solid-state outputs.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45152665501878,"sku":"TM5SDO4R","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/TM5SDO4R.jpg?v=1780301459","url":"https:\/\/www.plcsparehub.com\/products\/tm5sdo4r-modicon-tm5-relay-module-schneider-electric-discrete-output","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}