{"product_id":"tm5sai4l-12-bit-voltage-current-input-module-schneider-electric-modicon","title":"TM5SAI4L 12-Bit Voltage\/Current Input Module Schneider Electric Modicon","description":"\u003ch3\u003e\u003cb\u003eSignal Acquisition Architecture \u0026amp; System Role\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eSchneider Electric TM5SAI4L\u003c\/b\u003e\u003c\/font\u003e is an ultra-compact, 4-channel analog input slice designed for high-density distributed I\/O architectures within the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eModicon TM5\u003c\/b\u003e\u003c\/font\u003e system. Engineered to interface directly with industrial field transmitters, pressure transducers, and proportional valves, this electronic module supports software-selectable \u003cfont color=\"#0056b3\"\u003e\u003cb\u003e±10V DC\u003c\/b\u003e\u003c\/font\u003e, \u003cfont color=\"#0056b3\"\u003e\u003cb\u003e0-20 mA\u003c\/b\u003e\u003c\/font\u003e, and \u003cfont color=\"#0056b3\"\u003e\u003cb\u003e4-20 mA\u003c\/b\u003e\u003c\/font\u003e signals on every individual channel.\u003c\/p\u003e\n\u003cp\u003eCombining a 12.5 mm slim-profile footprint with deterministic sampling speeds down to 300 µs per channel, the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eTM5SAI4L\u003c\/b\u003e\u003c\/font\u003e delivers rapid closed-loop feedback and granular channel-level diagnostics for complex packaging, material handling, and OEM machine automation.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eHardware \u0026amp; Signal Specification Tree\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eIdentification \u0026amp; Platform Classification\u003c\/b\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cb\u003eManufacturer:\u003c\/b\u003e \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eSchneider Electric\u003c\/b\u003e\u003c\/font\u003e\n\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003ePart Number:\u003c\/b\u003e \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eTM5SAI4L\u003c\/b\u003e\u003c\/font\u003e\n\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003eProduct Series:\u003c\/b\u003e \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eModicon TM5\u003c\/b\u003e\u003c\/font\u003e Distributed I\/O System\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003eLifecycle Status:\u003c\/b\u003e Active OEM Production\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eAnalog Input \u0026amp; Conversion Performance\u003c\/b\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cb\u003eChannel Architecture:\u003c\/b\u003e 4 single-ended input channels (individually software configurable)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003eSupported Input Ranges:\u003c\/b\u003e ±10 Vdc voltage; 0-20 mA and 4-20 mA current loops\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003eDigital Resolution:\u003c\/b\u003e 12-bit signed integer representation (-32768 to +32767 across ±10V)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003eMeasurement Accuracy:\u003c\/b\u003e ±0.3% of full scale at 25°C (±0.5% FS across full thermal envelope)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003eSampling \u0026amp; Cycle Timing:\u003c\/b\u003e Selectable 1 ms or 300 µs per channel; 200 µs inter-channel offset; configurable digital filter (Off or Levels 2 to 128)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eIsolation, Diagnostics \u0026amp; Power Consumption\u003c\/b\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cb\u003eGalvanic Isolation:\u003c\/b\u003e 500 Vrms AC between field channels and internal TM5 bus (non-isolated between adjacent channels)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003eReal-Time Diagnostics:\u003c\/b\u003e Per-channel under-range, over-range, and 4-20 mA open-wire break detection, plus ModuleOK, DcOk, and NetworkOk status flags\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003ePower \u0026amp; Bus Draw:\u003c\/b\u003e 24 Vdc field supply via TM5 power distribution; 1.2 W total dissipation; 3 mA @ 5V DC (TM5 bus) and 10 mA @ 24V DC\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eMechanical \u0026amp; Environmental Envelope\u003c\/b\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cb\u003ePhysical Dimensions:\u003c\/b\u003e 99 × 12.5 × 75 mm (H × W × D); ultra-lightweight 0.025 kg mass\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003eThermal \u0026amp; Ingress Ratings:\u003c\/b\u003e 0°C to +55°C operating temperature; -25°C to +70°C storage; IP20 finger-safe housing\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eController Compatibility \u0026amp; Backplane Assembly\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eCompatible Logic Controllers\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cfont color=\"#0056b3\"\u003e\u003cb\u003eModicon M241\u003c\/b\u003e\u003c\/font\u003e, \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eModicon M251\u003c\/b\u003e\u003c\/font\u003e, \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eModicon M258\u003c\/b\u003e\u003c\/font\u003e, and \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eModicon LMC058\u003c\/b\u003e\u003c\/font\u003e motion controllers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eModular Slice Architecture\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eRequires matching TM5 bus base and 12-pin removable spring\/screw terminal block (sold separately)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eCommissioning Environment\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eConfigured natively inside EcoStruxure Machine Expert (formerly SoMachine) via drag-and-drop hardware trees\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cb\u003eField Wiring \u0026amp; Commissioning Best Practices\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eCommon-Reference Grounding:\u003c\/b\u003e Because the four channels share a common internal reference without channel-to-channel isolation, ensure all connected field transmitters use isolated power supplies or share an equipotential ground plane to eliminate ground loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eNoise Filtering Optimization:\u003c\/b\u003e Engage the hardware low-pass filter (Levels 2 through 128) in EcoStruxure Machine Expert when monitoring slow thermal or tank-level processes near variable frequency drives (VFDs).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eShield Termination:\u003c\/b\u003e Ground analog twisted-pair cable shields at one end only using dedicated TM5 shield-clamping bars to prevent circulating ground currents.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eEngineering Field Guide \u0026amp; Selection FAQ\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ: What happens if I connect two non-isolated, ground-referenced sensors at different ground potentials to Channels 1 and 2?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Since the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eTM5SAI4L\u003c\/b\u003e\u003c\/font\u003e lacks channel-to-channel isolation, ground potential differences will create circulating current errors and skew measurements across both inputs. Use external loop isolators for grounded field devices.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: How does the 4-20 mA wire-break diagnostic behave during normal machine startup?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: If a 4-20 mA transmitter drops below approximately 3.6 mA during power-up, the module triggers a channel under-range fault bit. Program a short startup timer in your PLC logic to mask alarms until field sensors stabilize.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: When should I switch the sampling rate from 1 ms to 300 µs per channel?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Select the 300 µs sampling mode for high-speed dynamic applications—such as tension control dancer arms or hydraulic pressure spikes—where fast PID loop updates are critical.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: Can I configure Channel 1 for ±10V DC while running 4-20 mA current loops on Channels 2, 3, and 4?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Each channel is independently configured via software parameters and dedicated wiring terminals on the terminal block, allowing mixed voltage and current signals on a single module.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: Does the TM5SAI4L include the bus base and front terminal strip in the box?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. Like all \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eModicon TM5\u003c\/b\u003e\u003c\/font\u003e electronic slices, the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eTM5SAI4L\u003c\/b\u003e\u003c\/font\u003e ships as the core electronic insert; verify that your TM5 bus base and terminal block are intact or order them separately for new panel builds.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":68083592036534,"sku":"TM5SAI4L","price":134.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/TM5SAI4L-1.jpg?v=1794898871","url":"https:\/\/www.plcsparehub.com\/products\/tm5sai4l-12-bit-voltage-current-input-module-schneider-electric-modicon","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}