{"product_id":"tm5sai2l-schneider-electric-modicon-tm5-2-channel-analog-input-module","title":"TM5SAI2L Schneider Electric Modicon TM5 2-Channel Analog Input Module","description":"\u003ch3\u003e\u003cstrong\u003eHardware Profile \u0026amp; Signal Acquisition Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eControl engineers integrate the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTM5SAI2L\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSchneider Electric\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eModicon TM5\u003c\/strong\u003e\u003c\/span\u003e 2-channel analog input module into distributed I\/O slices to digitize continuous process variables with high speed and minimal panel footprint. Each channel operates independently under software configuration, accepting ±10 Vdc bipolar voltage or 0–20 mA \/ 4–20 mA current loops at 12-bit signed resolution. Built-in hardware diagnostics continuously evaluate wire breaks, out-of-range limits, and bus health across \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eModicon M241, M251, M258, and LMC058\u003c\/strong\u003e\u003c\/span\u003e automation architectures.\u003c\/p\u003e\n\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" width=\"100%\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth align=\"left\"\u003eEngineering Domain\u003c\/th\u003e\n      \u003cth align=\"left\"\u003eTechnical Parameter\u003c\/th\u003e\n      \u003cth align=\"left\"\u003eRated Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIdentification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eManufacturer, Model \u0026amp; Series\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSchneider Electric TM5SAI2L\u003c\/strong\u003e\u003c\/span\u003e (\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eModicon TM5\u003c\/strong\u003e\u003c\/span\u003e Series)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSignal Acquisition\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eChannels \u0026amp; Signal Types\u003c\/td\u003e\n      \u003ctd\u003e2 Channels; ±10 Vdc, 0–20 mA, 4–20 mA (per-channel software configurable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConversion\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eResolution \u0026amp; Accuracy\u003c\/td\u003e\n      \u003ctd\u003e12-bit signed (-32768 to +32767); ±0.3% FS @ 25 °C (±0.5% FS max)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTiming \u0026amp; Filtering\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSampling \u0026amp; Response Time\u003c\/td\u003e\n      \u003ctd\u003e1 ms or 300 µs\/channel sampling; 200 µs offset; filter off or levels 2–128\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDielectric Strength\u003c\/td\u003e\n      \u003ctd\u003e500 Vrms AC (channels to TM5 bus); non-isolated between channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower \u0026amp; Bus Load\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSupply \u0026amp; Current Consumption\u003c\/td\u003e\n      \u003ctd\u003e24 Vdc supply (0.81 W total); 2 mA @ 5 V DC bus; 5 mA @ 24 V DC bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eThermal Span \u0026amp; Protection\u003c\/td\u003e\n      \u003ctd\u003e0 °C to +55 °C operating; -25 °C to +70 °C storage; IP20 ingress\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePhysical \u0026amp; Lifecycle\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDimensions, Mass \u0026amp; Status\u003c\/td\u003e\n      \u003ctd\u003e99 × 12.5 × 75 mm; 0.025 kg ultra-lightweight slice; Active lifecycle\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities \u0026amp; Integration Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePer-Channel Software Flexibility:\u003c\/strong\u003e Eliminates hardware DIP switches by letting programmers mix voltage and current sensors across Channel 0 and Channel 1 directly inside EcoStruxure Machine Expert.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGranular Fault Diagnostics:\u003c\/strong\u003e Reports real-time status flags including 4–20 mA open-wire detection, upper\/lower threshold breaches, \u003cem\u003eModuleOK\u003c\/em\u003e, \u003cem\u003eDcOk\u003c\/em\u003e, and \u003cem\u003eNetworkOk\u003c\/em\u003e directly to PLC registers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfigurable Digital Filtering:\u003c\/strong\u003e Adjustable low-pass filter levels (2 through 128) suppress high-frequency process noise without sacrificing rapid 300 µs conversion cycles when fast loop response is critical.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUltra-Dense Slice Packaging:\u003c\/strong\u003e Measures just 12.5 mm wide and weighs 25 grams, maximizing I\/O density inside compact machine-mounted junction boxes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eField Engineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How does the lack of channel-to-channel isolation affect wiring two separate sensors to the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTM5SAI2L\u003c\/strong\u003e\u003c\/span\u003e?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Because both channels share a common internal reference potential, connecting two grounded sensors with different ground potentials creates a ground loop error. Use signal isolators or floating ungrounded transmitters when wiring multiple channels simultaneously.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: How do I configure the 4–20 mA open-wire break diagnostic in EcoStruxure Machine Expert?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Select the 4–20 mA input range in the I\/O configuration tree; the firmware automatically flags a wire-break fault whenever loop current drops below roughly 3.6 mA, allowing your PLC logic to trigger a safe fallback routine.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: When should I choose the 300 µs sampling rate over the standard 1 ms sampling rate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Enable the 300 µs fast sampling mode for high-speed dynamic applications such as hydraulic cylinder pressure profiling or web tension control, while keeping standard 1 ms sampling with higher digital filtering for slow thermal or tank level loops.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: Can I mount this electronic slice directly onto a DIN rail without additional bus components?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: No, the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTM5SAI2L\u003c\/strong\u003e\u003c\/span\u003e is an electronic insert module that requires a compatible Modicon TM5 bus base and a 12-pin removable terminal block to complete the backplane power and field wiring connections.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: Why does my ±10 Vdc input reading show slight offset drift near the upper 55 °C cabinet limit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA5: Analog front-end reference components experience minor thermal drift across ambient extremes, shifting accuracy from ±0.3% FS at 25 °C to ±0.5% FS at 55 °C. Maintain adequate cabinet ventilation and keep high-heat power supplies separated from analog slices.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":68083588497590,"sku":"TM5SAI2L","price":111.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/TM5SAI2L-1.jpg?v=1794898774","url":"https:\/\/www.plcsparehub.com\/products\/tm5sai2l-schneider-electric-modicon-tm5-2-channel-analog-input-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}