{"product_id":"tc-ixl062-honeywell-experion-pks-thermocouple-input-module","title":"TC-IXL062 Honeywell Experion PKS Thermocouple Input Module","description":"\u003ch3\u003e\u003cstrong\u003eHoneywell TC-IXL062 | 6-Point Thermocouple Input Module\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #c0392b;\"\u003eHoneywell TC-IXL062\u003c\/span\u003e\u003c\/strong\u003e is a thermocouple input module designed for compatible Honeywell Experion PKS control system configurations. It provides six temperature measurement channels and two cold junction channels for thermocouple-based process measurement.\u003c\/p\u003e\n\n\u003cp\u003eThe module accepts low-level thermocouple signals across two specified input ranges: -12 mV to +78 mV and a high-resolution range of -12 mV to +30 mV. Its 16-bit resolution, channel-to-channel isolation, and cold junction compensation provisions support temperature acquisition in industrial process environments.\u003c\/p\u003e\n\n\u003cp\u003eFor engineering selection, three factors deserve particular attention: thermocouple type, cold junction sensor configuration, and Experion PKS software release. Types D and L are not supported in releases earlier than Experion PKS R210 patch 10, according to the supplied specification.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e01 | Measurement Channel Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003eTC-IXL062\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem family:\u003c\/strong\u003e Honeywell Experion PKS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Thermocouple input module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement channels:\u003c\/strong\u003e 6 thermocouple input channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction channels:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput range:\u003c\/strong\u003e -12 mV to +78 mV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-resolution input range:\u003c\/strong\u003e -12 mV to +30 mV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16 bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTypical resolution:\u003c\/strong\u003e 1.4 µV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-resolution range:\u003c\/strong\u003e 0.70 µV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput impedance:\u003c\/strong\u003e Greater than 10 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum power dissipation:\u003c\/strong\u003e 4.3 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal block:\u003c\/strong\u003e TC-TBNH, 20-position\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003e02 | Thermocouple Compatibility and Temperature Accuracy\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThermocouples produce low-level millivolt signals. Reliable temperature measurement therefore depends on the selected sensor type, input range, cold junction compensation, and installation conditions.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eEngineering consideration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported thermocouple types\u003c\/td\u003e\n\u003ctd\u003eB, E, J, K, R, S, T, N, C, D, L\u003c\/td\u003e\n\u003ctd\u003eVerify the sensor type against the system configuration and software release.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard input range\u003c\/td\u003e\n\u003ctd\u003e-12 mV to +78 mV\u003c\/td\u003e\n\u003ctd\u003eConfirm the expected thermocouple signal remains within the configured range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-resolution range\u003c\/td\u003e\n\u003ctd\u003e-12 mV to +30 mV\u003c\/td\u003e\n\u003ctd\u003eCheck the sensor's expected signal span before selecting this range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bits; 1.4 µV typical\u003c\/td\u003e\n\u003ctd\u003eResolution describes signal granularity, not total measurement accuracy.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-resolution setting\u003c\/td\u003e\n\u003ctd\u003e0.70 µV\u003c\/td\u003e\n\u003ctd\u003eUse the applicable range specification when evaluating measurement performance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy at 25°C, standard range\u003c\/td\u003e\n\u003ctd\u003e0.1% FSR ±90 µV\u003c\/td\u003e\n\u003ctd\u003eUse the specified full-scale range when calculating the applicable error budget.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy at 25°C, high-resolution range\u003c\/td\u003e\n\u003ctd\u003e0.1% FSR ±42 µV\u003c\/td\u003e\n\u003ctd\u003eConsider this specification together with sensor and cold junction errors.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold junction sensor error\u003c\/td\u003e\n\u003ctd\u003e±0.3°C\u003c\/td\u003e\n\u003ctd\u003eIncludes the specified local or remote cold junction sensor error.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eThermocouple selection note:\u003c\/strong\u003e Types D and L require Experion PKS R210 patch 10 or later according to the supplied documentation. If the installed system uses an earlier release, confirm supported sensor types before ordering or changing the configuration.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e03 | Cold Junction Compensation: Two Sensors Required\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThermocouple measurement requires cold junction compensation to account for the temperature at the reference junction. The TC-IXL062 specification identifies two cold junction channels and lists the spare cold junction thermistor as \u003cstrong\u003eTC-CJRT02\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpare CJR thermistor:\u003c\/strong\u003e TC-CJRT02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity specified:\u003c\/strong\u003e Two CJR thermistors per module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal cold junction sensor:\u003c\/strong\u003e Supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote cold junction sensor:\u003c\/strong\u003e Supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecified cold junction sensor error:\u003c\/strong\u003e ±0.3°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eWhen troubleshooting temperature offsets across several channels, check the cold junction sensor arrangement before replacing the input module. Confirm that the required thermistors are installed correctly and that the selected local or remote sensor configuration matches the actual wiring.\u003c\/p\u003e\n\n\u003cp\u003eA cold junction compensation fault can affect the reported temperature even when the thermocouple itself and the input wiring remain intact. The sensor type, reference temperature, terminal arrangement, and system configuration should therefore be checked as part of the measurement chain.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e04 | Signal Quality, Response Time and Isolation\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePerformance parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule update rate\u003c\/td\u003e\n\u003ctd\u003e50 ms for all channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSettling time to 5% of full scale\u003c\/td\u003e\n\u003ctd\u003eLess than 80 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel bandwidth\u003c\/td\u003e\n\u003ctd\u003e0 to 15 Hz at -3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal-mode noise rejection\u003c\/td\u003e\n\u003ctd\u003e60 dB at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon-mode rejection\u003c\/td\u003e\n\u003ctd\u003e160 dB minimum, tested at 600 VAC, 60 Hz, with 100 Ω imbalance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput offset drift\u003c\/td\u003e\n\u003ctd\u003e0.5 µV\/°C typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain drift\u003c\/td\u003e\n\u003ctd\u003e25 ppm\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain drift, standard range\u003c\/td\u003e\n\u003ctd\u003e2.3 µV for the -12 mV to +78 mV range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain drift, high-resolution range\u003c\/td\u003e\n\u003ctd\u003e1.1 µV for the -12 mV to +30 mV range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage capability\u003c\/td\u003e\n\u003ctd\u003e120 VAC\/VDC continuous at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-channel isolation\u003c\/td\u003e\n\u003ctd\u003e250 V; 100% tested at 1900 V for 2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser-to-system isolation\u003c\/td\u003e\n\u003ctd\u003e250 V; 100% tested at 1900 V for 2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power dissipation\u003c\/td\u003e\n\u003ctd\u003e4.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThe 50 ms module update rate and less-than-80 ms settling specification describe different aspects of response. They should not be interpreted as a guarantee of the total process-control response time, which also depends on system execution, configuration, and application logic.\u003c\/p\u003e\n\n\u003cp\u003eThe stated overvoltage capability is a module specification, not permission to apply abnormal voltage during routine operation. Maintain the intended thermocouple wiring and follow the manufacturer's installation requirements.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e05 | Open Thermocouple Detection and Diagnostic Checks\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe module specification identifies open thermocouple detection with an upscale reading. The stated typical detection time is two seconds. This is useful when investigating sensor wiring faults, but it should not be treated as a complete diagnostic system for every field-circuit failure.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen thermocouple indication:\u003c\/strong\u003e Inspect the sensor wiring, terminal connections, thermocouple junction, and extension cable for an open circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature reading is unusually high:\u003c\/strong\u003e Check whether the module is reporting an upscale reading associated with open-circuit detection. Verify the actual sensor circuit before assuming the process temperature is high.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReading is consistently offset:\u003c\/strong\u003e Confirm the thermocouple type, configured input range, cold junction sensor arrangement, and wiring polarity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReading fluctuates with electrical equipment:\u003c\/strong\u003e Inspect routing near drives, contactors, and other noise sources. Verify grounding, shielding, and separation of low-level sensor wiring from power wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeveral channels show similar errors:\u003c\/strong\u003e Check shared cold junction compensation, terminal block connections, configuration, and environmental conditions before concluding that multiple sensor elements have failed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReading does not settle as expected:\u003c\/strong\u003e Compare the observed behavior with the 50 ms update rate and less-than-80 ms settling specification. Account for sensor thermal response and process dynamics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eDiagnostic limitation:\u003c\/strong\u003e The supplied information does not establish a complete list of module alarm codes or channel-level diagnostic flags. Use the relevant Experion PKS diagnostic tools and hardware documentation to confirm the exact fault status and recovery procedure.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e06 | Compatible Hardware and Installation Planning\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe specified connection terminal block is the \u003cstrong\u003eTC-TBNH 20-position terminal block\u003c\/strong\u003e. Confirm that the installed hardware, module configuration, terminal block, and field wiring arrangement match the relevant Honeywell documentation.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal block:\u003c\/strong\u003e TC-TBNH, 20-position\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction accessories:\u003c\/strong\u003e TC-CJRT02 thermistors; the specification states that two are used per module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem compatibility:\u003c\/strong\u003e Verify the applicable Experion PKS configuration and software release\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor wiring:\u003c\/strong\u003e Confirm thermocouple type, polarity, extension-wire compatibility, and terminal assignment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput configuration:\u003c\/strong\u003e Confirm the selected measurement range and cold junction compensation mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower planning:\u003c\/strong\u003e Account for the maximum 4.3 W module dissipation and consult the system's module power consumption data for backplane current requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe exact supported chassis, mounting position, and replacement rules should be confirmed using the applicable system documentation. Do not infer full hardware compatibility from the model number alone.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e07 | Environmental and Electrical Installation Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal-mode noise rejection:\u003c\/strong\u003e 60 dB at 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon-mode rejection:\u003c\/strong\u003e 160 dB minimum under the specified test conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput impedance:\u003c\/strong\u003e Greater than 10 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage capability:\u003c\/strong\u003e 120 VAC\/VDC continuous at 25°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum power dissipation:\u003c\/strong\u003e 4.3 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe supplied specification lists RFI immunity as TBD. No definitive RFI immunity value should therefore be claimed from these data alone.\u003c\/p\u003e\n\n\u003cp\u003eFor installation, follow Honeywell requirements for terminal wiring, shielding, grounding, isolation, and cabinet conditions. Isolate equipment as required by site procedures before changing wiring or removing a module.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e08 | Global PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eWhen sourcing the \u003cstrong\u003e\u003cspan style=\"color: #c0392b;\"\u003eTC-IXL062\u003c\/span\u003e\u003c\/strong\u003e, verify the thermocouple type and Experion PKS release before checking price and availability. A module may have the required channel count yet still be unsuitable for a specific installation if the configured sensor type or cold junction arrangement is unsupported.\u003c\/p\u003e\n\n\u003cp\u003eFor temperature measurement problems, compare the full measurement chain: sensor type, thermocouple extension wiring, terminal block, cold junction thermistors, configured input range, and reported process value. This is often more useful than replacing the input module based on an offset reading alone.\u003c\/p\u003e\n\n\u003cp\u003eGlobal PLC Spare HUB supports industrial automation spare-parts sourcing and model verification for maintenance and replacement projects. Provide the complete model, installed system details, and required quantity so our team can review the order information before quotation.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e09 | Warranty, Shipping and Supply\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Honeywell TC-IXL062 Thermocouple Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months, subject to the agreed warranty terms and confirmed product condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping options:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch:\u003c\/strong\u003e Typically arranged within 24–48 hours after stock and payment confirmation, where available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder verification:\u003c\/strong\u003e Confirm stock status, condition, lead time, shipping charges, terminal block requirements, and system compatibility before purchase.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003e10 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1. Can the TC-IXL062 measure Type D and Type L thermocouples on every Experion PKS release?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eNo. According to the supplied specification, Types D and L are not supported in releases earlier than Experion PKS R210 patch 10. Verify the installed software release and the configured sensor type before using either thermocouple type.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2. Why can two channels using the same thermocouple type show different temperatures?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eCheck sensor calibration, extension-wire material, terminal connections, polarity, and the physical temperature at the reference junction. Differences in cold junction compensation or field wiring can create offsets even when both channels use the same thermocouple type. Compare the readings against a suitable reference instrument before replacing the module.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3. When should I choose the high-resolution input range?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eUse the -12 mV to +30 mV range only when the expected thermocouple signal fits within that range and the application benefits from its specified 0.70 µV resolution. Confirm the full operating temperature span and sensor type before changing ranges. Do not select a narrower range without checking the potential for out-of-range readings.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4. What should I investigate if a temperature channel reports an upscale value?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eStart by checking the thermocouple circuit for an open connection, because the specification identifies upscale reading as the open-circuit detection behavior. Inspect the sensor, extension cable, terminal block, and wiring continuity. Confirm the system's channel status and configured sensor type before interpreting the reading as an actual process overtemperature.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5. What should I confirm when purchasing a replacement module for an existing DCS?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eProvide the complete TC-IXL062 model number, installed Experion PKS release, thermocouple types in use, terminal block model, cold junction sensor arrangement, and required quantity. If the system uses Type D or L sensors, include the software release information. These details help identify configuration considerations before the order is finalized.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eRequest a Quote for TC-IXL062\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eLooking for a Honeywell thermocouple input module for an existing Experion PKS installation? Contact Global PLC Spare HUB with the part number, system release, required quantity, and delivery destination. Request a quotation for availability, lead time, shipping options, and compatibility review.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67819992252598,"sku":"TC-IXL062","price":158.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/TC-IXL062-1.jpg?v=1793068777","url":"https:\/\/www.plcsparehub.com\/products\/tc-ixl062-honeywell-experion-pks-thermocouple-input-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}