{"product_id":"tc-ixl061-honeywell-temperature-input-i-o-module","title":"TC-IXL061 Honeywell Temperature Input I\/O Module","description":" \u003ch3\u003e\u003cstrong\u003eHoneywell TC-IXL061 Thermocouple Input Module\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TC-IXL061\u003c\/strong\u003e is a six-point thermocouple input module designed to acquire temperature-related millivolt signals from industrial thermocouples. It supports nine thermocouple types and provides a dedicated cold junction (CJ) channel for reference-junction compensation.\u003c\/p\u003e\n\n\u003cp\u003eWith 16-bit resolution, a 50 ms update rate across all channels, and configurable measurement ranges, the TC-IXL061 supports temperature monitoring in process control systems where signal integrity, sensor diagnostics, and measurement consistency are important. Its 20-position TC-TBNH terminal block provides the field connection interface.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eReplacement note:\u003c\/strong\u003e The TC-IXL061 has been superseded by the TC\/TK-IXL062 according to the supplied product information. The replacement requires terminal-block rewiring. Applications using an RTP also require a new pre-wired cable. Confirm the exact module designation and wiring documentation before ordering or beginning a retrofit.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-IXL061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eThermocouple input module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e6 thermocouple channels plus 1 cold junction channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Input Range\u003c\/td\u003e\n\u003ctd\u003e-12 mV to +78 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Resolution Input Range\u003c\/td\u003e\n\u003ctd\u003e-12 mV to +30 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Thermocouple Types\u003c\/td\u003e\n\u003ctd\u003eB, E, J, K, R, S, T, N, C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bits; 1.4 µV typical; 0.70 µV on the high-resolution range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy, Standard Range at 25°C\u003c\/td\u003e\n\u003ctd\u003e0.1% FSR ±90 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy, High-Resolution Range at 25°C\u003c\/td\u003e\n\u003ctd\u003e0.1% FSR ±42 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Cold Junction Sensor Error\u003c\/td\u003e\n\u003ctd\u003e±0.3°C to ±3.0°C, depending on channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote Cold Junction Sensor Error\u003c\/td\u003e\n\u003ctd\u003e±0.3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAll-Channel Update Rate\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSettling Time to 5% of Full Scale\u003c\/td\u003e\n\u003ctd\u003eLess than 80 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-Thermocouple Detection\u003c\/td\u003e\n\u003ctd\u003eTypically 5 seconds; upscale reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Bandwidth\u003c\/td\u003e\n\u003ctd\u003e0 to 15 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon-Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e120 dB at 60 Hz; 100 dB at 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal-Mode Noise Rejection\u003c\/td\u003e\n\u003ctd\u003e60 dB at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRFI Immunity\u003c\/td\u003e\n\u003ctd\u003eError below 2.0% of range at 10 V\/m, 27–1000 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Overvoltage Capability\u003c\/td\u003e\n\u003ctd\u003e120 VAC\/VDC at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Offset Drift\u003c\/td\u003e\n\u003ctd\u003e0.5 µV\/°C typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain Drift\u003c\/td\u003e\n\u003ctd\u003e65 ppm\/°C typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e4.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare CJ Thermistor\u003c\/td\u003e\n\u003ctd\u003eTC-CJRT01, part number 51109433-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block\u003c\/td\u003e\n\u003ctd\u003eTC-TBNH, 20-position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Channel Isolation\u003c\/td\u003e\n\u003ctd\u003e100% tested at 2546 VDC for 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser-to-System Isolation\u003c\/td\u003e\n\u003ctd\u003e100% tested at 2546 VDC for 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eFSR means full-scale range. Backplane current should be checked against the applicable Honeywell module power-consumption documentation. Verify all specifications against the manual for the installed hardware revision.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eMeasurement Architecture: Six Inputs and Cold Junction Compensation\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe TC-IXL061 measures the millivolt signal generated by each connected thermocouple. Since thermocouple voltage depends on the temperature difference between the measuring junction and the reference junction, reliable temperature calculation also requires cold junction compensation.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix measurement channels:\u003c\/strong\u003e Acquire temperature signals from separate process points, subject to the configured thermocouple type and input range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction channel:\u003c\/strong\u003e Provides the reference information needed for thermocouple compensation. The installed configuration determines whether local or remote compensation applies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-resolution range:\u003c\/strong\u003e The -12 mV to +30 mV range provides a specified resolution of 0.70 µV. Confirm that the expected sensor signal remains within the selected range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput noise rejection:\u003c\/strong\u003e Common-mode and normal-mode rejection specifications help engineers assess signal quality in electrically noisy cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen-sensor detection:\u003c\/strong\u003e The module typically detects an open thermocouple in 5 seconds and reports an upscale reading.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eAn upscale reading should be treated as a diagnostic indication rather than proof of an open sensor. Confirm the channel status, field wiring, sensor continuity, and configured thermocouple type before making a maintenance decision.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eFor maintenance engineers, the main selection issue is not simply the number of thermocouple inputs. The configured sensor type, cold junction arrangement, wiring method, and replacement interface all affect the validity of the temperature value delivered to the control application.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck sensor configuration:\u003c\/strong\u003e Verify whether each field sensor is Type B, E, J, K, R, S, T, N, or C. An incorrect type selection can produce plausible but inaccurate temperature readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInvestigate channel-to-channel differences:\u003c\/strong\u003e If similar process points show unexpected offsets, compare sensor type, polarity, terminal condition, cable routing, and cold junction conditions before replacing the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparate sensor faults from input faults:\u003c\/strong\u003e Inspect the thermocouple and extension wiring first. If the fault persists, compare the affected channel with a known-good channel using an approved test procedure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview the installation enclosure:\u003c\/strong\u003e The supplied guidance recommends a NEMA 4 or NEMA 12 enclosure approximately 610 mm wide, 508 mm high, and 203 mm deep to maintain approximately ±3°C reference-junction compensation. Confirm the applicable manual and installation conditions before treating this enclosure dimension as a universal requirement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlan replacements before shutdown:\u003c\/strong\u003e The TC\/TK-IXL062 replacement requires terminal-block rewiring, and RTP installations require a new pre-wired cable. Include wiring drawings, cable procurement, configuration checks, and post-installation validation in the maintenance plan.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSuitable Equipment and Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication Area\u003c\/th\u003e\n\u003cth\u003eTypical Measurement Points\u003c\/th\u003e\n\u003cth\u003eEngineering Consideration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess manufacturing\u003c\/td\u003e\n\u003ctd\u003eHeated vessels, process lines, and thermal stages\u003c\/td\u003e\n\u003ctd\u003eMatch the thermocouple type and input range to the expected temperature signal.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnaces and thermal equipment\u003c\/td\u003e\n\u003ctd\u003eHeating zones and temperature profiles\u003c\/td\u003e\n\u003ctd\u003eConfirm sensor suitability, range limits, and cold junction compensation requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilities and energy systems\u003c\/td\u003e\n\u003ctd\u003eEquipment temperatures and thermal process monitoring\u003c\/td\u003e\n\u003ctd\u003eCheck noise exposure, cable routing, and measurement response requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial machinery\u003c\/td\u003e\n\u003ctd\u003eMotor, bearing, or process-equipment temperature points where thermocouples are specified\u003c\/td\u003e\n\u003ctd\u003eVerify that the selected sensor and control-system design support the intended measurement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl-system maintenance\u003c\/td\u003e\n\u003ctd\u003eExisting six-point thermocouple input installations\u003c\/td\u003e\n\u003ctd\u003eConfirm hardware revision, terminal-block wiring, and replacement cable requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThese are potential application areas for thermocouple input modules, not a claim that every listed installation is compatible with the TC-IXL061. Confirm the target Honeywell control platform and approved module configuration before installation.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Guide for Field Engineers\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved Symptom\u003c\/th\u003e\n\u003cth\u003ePossible Cause\u003c\/th\u003e\n\u003cth\u003eRecommended Checks\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpscale reading on one channel\u003c\/td\u003e\n\u003ctd\u003eOpen thermocouple, loose terminal, broken extension wire, or connection fault\u003c\/td\u003e\n\u003ctd\u003eInspect field wiring and terminal tightness; verify continuity and channel status.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature offset across multiple channels\u003c\/td\u003e\n\u003ctd\u003eIncorrect sensor-type configuration, cold junction issue, or common wiring error\u003c\/td\u003e\n\u003ctd\u003eCompare configured sensor types, polarity, terminal conditions, and CJ configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnstable readings near electrical equipment\u003c\/td\u003e\n\u003ctd\u003eElectromagnetic interference, poor shielding, or unsuitable cable routing\u003c\/td\u003e\n\u003ctd\u003eInspect cable routing and grounding practices; separate low-level sensor wiring from power conductors where required.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnexpected clipping or out-of-range values\u003c\/td\u003e\n\u003ctd\u003eInput range mismatch or sensor signal outside the configured range\u003c\/td\u003e\n\u003ctd\u003eCompare the expected thermocouple millivolt signal with the selected range and configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature changes after module replacement\u003c\/td\u003e\n\u003ctd\u003eDifferent terminal wiring, sensor configuration, or cold junction arrangement\u003c\/td\u003e\n\u003ctd\u003eCompare as-built wiring and configuration records with the replacement module documentation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeveral channels fail after a retrofit\u003c\/td\u003e\n\u003ctd\u003eTerminal-block rewiring error, incorrect cable, or configuration mismatch\u003c\/td\u003e\n\u003ctd\u003eStop relying on the affected readings until wiring, channel mapping, and system status are verified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eDiagnostic caution:\u003c\/strong\u003e The open-thermocouple function typically takes 5 seconds. A normal reading during this interval does not necessarily rule out an intermittent wiring fault. Use the control-system diagnostics and an approved sensor test procedure to confirm the cause.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation and Commissioning Checklist\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the hardware:\u003c\/strong\u003e Confirm the TC-IXL061 model, module revision, terminal block, and control-system compatibility from the applicable documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck field sensor assignments:\u003c\/strong\u003e Record the thermocouple type, channel number, polarity, and expected operating range for each input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the reference junction:\u003c\/strong\u003e Verify the local or remote cold junction arrangement and the associated sensor or thermistor configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the terminal interface:\u003c\/strong\u003e Confirm the TC-TBNH 20-position terminal block and ensure that field connections match the approved wiring diagram.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidate the enclosure:\u003c\/strong\u003e Review enclosure rating, dimensions, ambient conditions, and the manufacturer's installation recommendations for reference-junction compensation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest before returning to service:\u003c\/strong\u003e Confirm channel mapping, plausible readings, open-sensor diagnostics, and control-system alarm behavior under the approved commissioning procedure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument the result:\u003c\/strong\u003e Record sensor types, configuration values, wiring changes, measured offsets, and any replacement-related adjustments.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cp\u003eFollow the plant's lockout\/tagout procedures and applicable electrical safety rules before handling field wiring. Do not disconnect or test live circuits unless the approved procedure explicitly permits it.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eReplacement Planning: TC-IXL061 to TC\/TK-IXL062\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe TC-IXL061 is identified in the supplied information as superseded by the TC\/TK-IXL062. Because a replacement may involve interface changes, confirm the exact ordering code before purchasing.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eCompare the installed module label with the requested replacement part number.\u003c\/li\u003e\n\u003cli\u003eObtain the correct terminal-block wiring information for the replacement module.\u003c\/li\u003e\n\u003cli\u003eIf an RTP is installed, confirm and order the required replacement pre-wired cable.\u003c\/li\u003e\n\u003cli\u003eVerify thermocouple channel mapping, cold junction configuration, and control-system support.\u003c\/li\u003e\n\u003cli\u003ePlan a controlled commissioning test before returning temperature-dependent control functions to normal operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDo not assume that matching channel counts guarantee plug-and-play compatibility. The replacement decision should be based on the hardware revision, system documentation, wiring interface, and approved configuration.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1. What information should be provided when requesting a quotation for the TC-IXL061?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eProvide the full model number, any available part number, the installed control-system platform, the required quantity, and whether the purchase is for an existing installation or a planned retrofit. If replacing an installed unit, include the terminal-block and RTP details so the replacement requirements can be reviewed.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2. How should engineers evaluate a temperature reading that is stable but consistently different from a reference instrument?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eFirst compare the reference instrument's sensor type, calibration status, measurement location, and response characteristics. Then check the TC-IXL061 channel configuration, cold junction compensation, terminal temperature conditions, and wiring polarity. A stable offset does not by itself prove that the input module is defective.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3. Is the high-resolution input range automatically the best choice for every thermocouple?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eNo. The -12 mV to +30 mV range offers finer specified voltage resolution, but the expected sensor signal must remain within that range. Select the input range using the thermocouple type and expected operating conditions, and verify the configured range against the Honeywell documentation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4. What should be checked before using a spare cold junction thermistor?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eConfirm that the required component is TC-CJRT01, part number 51109433-100, and verify that the installed module configuration supports the intended cold junction arrangement. Check the connection method and the applicable installation instructions before fitting a spare part.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5. What documentation should be retained after replacing the TC-IXL061?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eKeep the original and replacement part numbers, module revision details, revised terminal wiring, any RTP cable part number, channel-to-sensor mapping, configuration records, and commissioning results. These records help the next maintenance team distinguish a hardware problem from a wiring or configuration change.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eOrdering, Warranty and Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Honeywell TC-IXL061 Thermocouple Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnical confirmation:\u003c\/strong\u003e Contact Global PLC Spare HUB with the complete model number and application details.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty, subject to the supplier's applicable terms and conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping options:\u003c\/strong\u003e FedEx, UPS, or DHL, subject to destination and shipment arrangements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement support:\u003c\/strong\u003e Confirm terminal-block rewiring and RTP cable requirements before ordering a TC\/TK-IXL062 replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eRequest a quotation:\u003c\/strong\u003e Contact Global PLC Spare HUB to confirm model identification, replacement requirements, pricing, and shipping options for the Honeywell TC-IXL061.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67819945132214,"sku":"TC-IXL061","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/TC-IXL061-1.jpg?v=1793068790","url":"https:\/\/www.plcsparehub.com\/products\/tc-ixl061-honeywell-temperature-input-i-o-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}