{"product_id":"tc-fccn01-honeywell-flex-i-o-controlnet-network-interface-card","title":"TC-FCCN01 Honeywell Flex I\/O ControlNet Network Interface Card","description":"\u003ch3\u003e\u003cb\u003eProduct Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb style=\"color: #0056b3;\"\u003eHoneywell\u003c\/b\u003e \u003cb style=\"color: #0056b3;\"\u003eTC-FCCN01\u003c\/b\u003e serves as a rugged ControlNet network gateway adapter designed to interface remote distribution clusters with a centralized processing network.\u003c\/p\u003e\n\u003cp\u003eThis network interface module manages a local backplane rail, enabling high-speed, deterministic data exchange across non-redundant media architectures.\u003c\/p\u003e\n\u003cp\u003eBy providing an isolated communication bridge, it coordinates cyclic and acyclic message transfers between field point groupings and supervisory controllers.\u003c\/p\u003e\n\u003cp\u003eSystem designers deploy this gateway to establish reliable, deterministic remote drop nodes inside space-constrained or hazardous industrial manufacturing sectors.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eCore Identification:\u003c\/b\u003e Manufactured by \u003cb style=\"color: #0056b3;\"\u003eHoneywell\u003c\/b\u003e. The definitive catalog part number is \u003cb style=\"color: #0056b3;\"\u003eTC-FCCN01\u003c\/b\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNetwork Interface Type:\u003c\/b\u003e Functions as a dedicated \u003cb style=\"color: #0056b3;\"\u003eControlNet gateway\u003c\/b\u003e operating on a non-redundant coaxial media bus structure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eBackplane Module Capacity:\u003c\/b\u003e Capable of driving and addressing up to 8 local expansion input-output hardware modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCommunication Data Rate:\u003c\/b\u003e Sustains a high-speed, deterministic serial network transmission speed of 5M bit\/s.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInput Operating Power:\u003c\/b\u003e Rated for a nominal input of 24V DC, with a functional operational envelope spanning from 19.2V to 31.2V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eBackplane Current Delivery:\u003c\/b\u003e Supplies an internal Flexbus logic output current limit of up to 640mA maximum at 5V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCurrent Draw \u0026amp; Load:\u003c\/b\u003e Consumes a maximum current of 400mA when fed from a standard, stable external 24V supply line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eThermal Matrix Parameters:\u003c\/b\u003e Generates a maximum power dissipation of 4.6W paired with a thermal dissipation rate of 15.7 BTU\/hr at 19.2V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDielectric Voltage Isolation:\u003c\/b\u003e Provides a robust 500V AC isolation barrier separating external user input power lines from the logic backplane bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConductor Connection Bounds:\u003c\/b\u003e Terminal block screw structures support copper conductors up to a maximum wire size of 12 AWG (4mm²).\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePhysical Dimensions:\u003c\/b\u003e Compact enclosure footprint measures exactly 87mm x 94mm x 69mm (3.4in x 3.7in x 2.7in).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eInstallation Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eFirst, secure the adapter interface firmly onto standard industrial DIN rail or via dedicated panel surface mounting standoffs.\u003c\/p\u003e\n\u003cp\u003eVerify that the external power distribution lines are sourced from a verified SELV (Safety Extra Low Voltage) or PELV (Protected Extra Low Voltage) supply.\u003c\/p\u003e\n\u003cp\u003eInsert the 24V DC positive and negative copper power conductors into the terminal blocks, utilizing a calibrated tool to torque the terminal screws to 7-9 inch-pounds.\u003c\/p\u003e\n\u003cp\u003eConnect the ControlNet coaxial drop line directly to the onboard BNC network connection port using premium-grade Belden RG-6\/U Quad Shield cable.\u003c\/p\u003e\n\u003cp\u003eSlide the adjacent expansion hardware points onto the integrated backplane connection rail, ensuring the communication joints engage cleanly.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eDebugging and Maintenance Convenience\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe front housing integrates a dual-status LED diagnostic display matrix consisting of Comm A and I\/O Status indicators for rapid field troubleshooting.\u003c\/p\u003e\n\u003cp\u003eStandard software profiling tools allow remote engineers to poll internal adapter diagnostics and verify slave module orientation over the network track.\u003c\/p\u003e\n\u003cp\u003eThe module framework allows independent replacement of the electronic interface housing without disturbing the primary physical coaxial cabling infrastructure.\u003c\/p\u003e\n\u003cp\u003eThe explicit torque specification markings (7-9 in-lbs) help on-site technicians establish uniform contact tension, preventing intermittent power resets.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eCompatibility Notes\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThis network adapter couples natively with standard modular distributed hardware rails containing up to 8 compatible expansion slots.\u003c\/p\u003e\n\u003cp\u003eThe communication interface parameters match standard ControlNet scanners, scheduling software tools, and active coaxial network taps.\u003c\/p\u003e\n\u003cp\u003eThe high-capacity 640mA logic output power envelope matches the aggregated current demands of multi-channel discrete, analog, and specialized modules.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSafety and Certification Matrix\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHazardous Area Classification: Class I Division 2 Certified for Groups A, B, C, and D environments\u003c\/li\u003e\n\u003cli\u003eInternational Zone Safety Compliance: Class I Zone 2 Group IIC Certified\u003c\/li\u003e\n\u003cli\u003eVibration Stress Resistance: Verified to 5g acceleration at 10-500Hz frequencies following rigorous IEC 68-2-6 test frameworks\u003c\/li\u003e\n\u003cli\u003eMechanical Shock Limits: Rated to withstand a 30g operational peak acceleration pulse, and up to a 50g peak non-operational impact shock\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003ePacking List and Warranty Terms\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe factory packaging contains 1 genuine \u003cb style=\"color: #0056b3;\"\u003eHoneywell\u003c\/b\u003e \u003cb style=\"color: #0056b3;\"\u003eTC-FCCN01\u003c\/b\u003e non-redundant ControlNet gateway interface adapter.\u003c\/p\u003e\n\u003cp\u003eThe unit delivers sealed inside an industrial-grade anti-static shielding container alongside technical hardware parameter reference documentation.\u003c\/p\u003e\n\u003cp\u003eThis network interface card includes a full 12-month commercial replacement warranty covering all electronic internal tracking components.\u003c\/p\u003e\n\u003cp\u003eThe active warranty coverage matrix initializes automatically on the precise calendar date the product arrives at your production facility.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eShipping Logistics\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eOur centralized distribution warehouses manage careful item inspection and secure dispatch within 24 to 48 hours of order clearance.\u003c\/p\u003e\n\u003cp\u003eWe execute premium expedited global delivery options using the industry's highest-tier express carrier networks including DHL, FedEx, and UPS.\u003c\/p\u003e\n\u003cp\u003eYour tracking coordinator receives real-time shipping tracking codes via automated email messages immediately upon transit vehicle departure.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTypical Application Scenarios\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eRemote pumping stations utilize this gateway to bridge localized chemical dosing points back to a master processing terminal over a long coaxial segment.\u003c\/p\u003e\n\u003cp\u003eMaterial handling facilities mount this adapter on localized conveyor sections to consolidate proximity switch clusters onto a single node.\u003c\/p\u003e\n\u003cp\u003eFood and beverage processing lines deploy the unit to manage discrete temperature-sensing module groups on cooking or pasteurization racks.\u003c\/p\u003e\n\u003cp\u003eIt integrates effectively with gas blending stations, packaging machineries, grain elevator controls, and basic paint spray lines.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eDiagnostic Capabilities\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module monitors internal backplane load values constantly, safeguarding the system if slave module current demands cross the 640mA threshold.\u003c\/p\u003e\n\u003cp\u003eThe front-panel Comm A LED alternates between solid and flashing states to pinpoint configuration mismatches or active trunk cable ruptures.\u003c\/p\u003e\n\u003cp\u003eThe I\/O Status indicator monitors local module communication, changing color states if a connected slot device goes offline or fails initialization checks.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb style=\"color: #0056b3;\"\u003eHoneywell\u003c\/b\u003e \u003cb style=\"color: #0056b3;\"\u003eTC-FCCN01\u003c\/b\u003e is a highly efficient choice for plants running established ControlNet backbones that do not require the cost overhead of redundant cabling paths.\u003c\/p\u003e\n\u003cp\u003eIts small 87mm x 94mm size allows it to fit easily inside shallow junction boxes, making it ideal for distributed terminal panels close to machinery.\u003c\/p\u003e\n\u003cp\u003eThe strict requirement for SELV\/PELV power options guarantees that the unit remains immune to grid power surges, protecting your downstream expansion modules from harm.\u003c\/p\u003e\n\u003cp\u003eFor facility teams looking to expand their legacy network footprint while preserving deterministic timing parameters, this card offers a very reliable solution.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSelection Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eEnsure your network topology requires a non-redundant media adapter, as this unit does not feature secondary redundant trunk connections.\u003c\/p\u003e\n\u003cp\u003eVerify that the cumulative current consumption of your 8 expansion cards does not exceed the 640mA logic limit at 5V DC.\u003c\/p\u003e\n\u003cp\u003eConfirm that your field installation panels can provide the necessary 19.2V to 31.2V DC input voltage range, accounting for potential AC ripple factors.\u003c\/p\u003e\n\u003cp\u003eSelect heavy-duty 12 AWG stranded copper cabling if your electrical layout requires long power runs prone to voltage drop challenges.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQuestion:\u003c\/b\u003e What do the different color transitions on the Comm A faceplate LED indicator mean during standard plant operations?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAnswer:\u003c\/b\u003e The Comm A LED uses red and green states to signal physical bus link health, identifying issues like lost network scheduling or broken cable lines.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQuestion:\u003c\/b\u003e Can I use a standard commercial power supply to run this gateway module while maintaining full European CE compliance?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAnswer:\u003c\/b\u003e No, to comply with CE Low Voltage Directives, you must use a verified Safety Extra Low Voltage (SELV) or Protected Extra Low Voltage (PELV) power source.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQuestion:\u003c\/b\u003e Does the onboard RJ-45 Network Access Port support direct programming connections via standard Ethernet cables?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAnswer:\u003c\/b\u003e No, this RJ-45 port is a dedicated serial Network Access Port (NAP) designed for a specific ControlNet programming cable (like the 1786-CP), and standard Ethernet links are not supported.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQuestion:\u003c\/b\u003e What is the absolute maximum number of expansion hardware points I can mount onto a single adapter branch?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAnswer:\u003c\/b\u003e The internal addressing logic of the adapter is built to support a maximum capacity of up to 8 local expansion modules.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQuestion:\u003c\/b\u003e How much torque should be applied to the terminal connection screws when securing the power supply wires?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAnswer:\u003c\/b\u003e The terminal block connector screws should be tightened to a specific torque setting between 7 and 9 inch-pounds to prevent loose connections.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/TC-FCCN01.png?v=1779094395\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45131201151158,"sku":"TC-FCCN01","price":186.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/TC-FCCN01.jpg?v=1779094395","url":"https:\/\/www.plcsparehub.com\/products\/tc-fccn01-honeywell-flex-i-o-controlnet-network-interface-card","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}