{"product_id":"stbpdt3100-schneider-electric-advantys-stb-24v-dc-power-distribution-module","title":"STBPDT3100 Schneider Electric Advantys STB 24V DC Power Distribution Module","description":"\u003ch3\u003e\u003cstrong\u003ePower Distribution Architecture \u0026amp; Role\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSystem integrators deploy the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSTBPDT3100\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSchneider Electric\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eAdvantys STB\u003c\/strong\u003e\u003c\/span\u003e 24V DC Power Distribution Module (PDM) to establish isolated power segments along distributed I\/O islands. By separating 24V DC sensor input power from actuator output power, this module allows engineers to safely de-energize field actuators during emergency stops while keeping diagnostic input sensors powered and online. It mounts onto an \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSTBXBA2200\u003c\/strong\u003e\u003c\/span\u003e base and draws zero current from the internal 5V logic bus.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Identification \u0026amp; Hardware Base:\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSTBPDT3100\u003c\/strong\u003e\u003c\/span\u003e (\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eAdvantys STB\u003c\/strong\u003e\u003c\/span\u003e Series)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eRequired I\/O Base:\u003c\/strong\u003e STBXBA2200 mounting base (18.4 mm width profile)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eLogic Bus Draw:\u003c\/strong\u003e 0 mA nominal consumption on the 5V island logic power supply\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eHot-Swap Status:\u003c\/strong\u003e Not supported (power must be removed prior to module extraction)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor \u0026amp; Actuator Bus Electrical Ratings:\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eInput Supply Voltage:\u003c\/strong\u003e 24V DC nominal (19.2 to 30V DC allowable operating range)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eSensor Input Bus Current:\u003c\/strong\u003e 4 A max at 30 °C; derates linearly to 2.5 A max at 60 °C\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eActuator Output Bus Current:\u003c\/strong\u003e 8 A max at 30 °C; derates linearly to 5 A max at 60 °C\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eGround Terminal Surge Capacity:\u003c\/strong\u003e 30 A maximum fault current for up to 2 minutes\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Circuit Protection \u0026amp; Enclosure:\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eOvercurrent Fusing:\u003c\/strong\u003e 5 A time-delayed fuse on input bus; 10 A time-delayed fuse on output bus\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003ePolarity Safeguard:\u003c\/strong\u003e Built-in reverse polarity protection on the actuator power bus\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP20 rated modular housing for enclosed cabinet mounting\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications Matrix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" width=\"100%\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth align=\"left\"\u003eCircuit Domain\u003c\/th\u003e\n      \u003cth align=\"left\"\u003eParameter\u003c\/th\u003e\n      \u003cth align=\"left\"\u003eEngineering Rating\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIdentification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eManufacturer \u0026amp; Part Number\u003c\/td\u003e\n      \u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSchneider Electric STBPDT3100\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNominal \u0026amp; Allowable Range\u003c\/td\u003e\n      \u003ctd\u003e24V DC (19.2–30V DC sensor\/actuator bus)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eInput Bus (Sensor Power)\u003c\/td\u003e\n      \u003ctd\u003e4 A @ 30 °C \/ 2.5 A @ 60 °C (5 A time-delayed fuse)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOutput Bus (Actuator Power)\u003c\/td\u003e\n      \u003ctd\u003e8 A @ 30 °C \/ 5 A @ 60 °C (10 A time-delayed fuse)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolarity \u0026amp; Grounding\u003c\/td\u003e\n      \u003ctd\u003eActuator reverse polarity protected; 30 A (2 min) ground rating\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBase Footprint \u0026amp; Ingress\u003c\/td\u003e\n      \u003ctd\u003eSTBXBA2200 (18.4 mm wide); IP20 protection rating\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eField Engineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why does the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSTBPDT3100\u003c\/strong\u003e\u003c\/span\u003e require a dedicated STBXBA2200 mounting base instead of standard 13.9 mm I\/O bases?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The STBXBA2200 base features an 18.4 mm width with heavy-duty internal power bus bars designed to safely carry up to 8 A of actuator current and break the upstream power distribution segment cleanly.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: How do I calculate when to insert an additional PDM along an Advantys STB island?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Sum the total steady-state and inrush currents of all downstream input and output modules. Whenever the combined load approaches 4 A on the input bus or 8 A on the output bus at 30 °C, install a new \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSTBPDT3100\u003c\/strong\u003e\u003c\/span\u003e to start a fresh power group.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Can I replace the internal 5 A and 10 A time-delayed fuses in the field if a short circuit trips them?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes, the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSTBPDT3100\u003c\/strong\u003e\u003c\/span\u003e houses user-accessible miniature time-delayed fuses under its front cover. Always isolate the external 24V DC supply and clear the field wiring fault before inserting replacement fuses of identical amperage.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: Why is hot-swapping prohibited on this power distribution module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Extracting the PDM under full inductive actuator load can cause electrical arcing across the STBXBA2200 backplane contacts, pitting the pins and inducing voltage spikes that disrupt the adjacent 5V logic communication bus.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: How does separating sensor and actuator buses improve machine safety compliance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA5: By wiring the actuator bus through an external safety relay, an E-Stop event cuts 24V DC power exclusively to solenoid valves and motor starters while keeping the sensor bus active so the PLC retains full visibility of machine state.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":68083572211894,"sku":"STBPDT3100","price":103.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/STBPDT3100K_c2537bab-e05c-4af4-81d9-db1105341c33.jpg?v=1794898275","url":"https:\/\/www.plcsparehub.com\/products\/stbpdt3100-schneider-electric-advantys-stb-24v-dc-power-distribution-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}