{"product_id":"stbart0200-2-channel-rtd-tc-mv-module-schneider-electric-advantys-stb","title":"STBART0200 2-Channel RTD\/TC\/mV Module Schneider Electric Advantys STB","description":"\u003ch3\u003e\u003cb\u003eEngineering Core \u0026amp; Architectural Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eSchneider Electric STBART0200\u003c\/b\u003e\u003c\/font\u003e is a high-precision 2-channel analog input module engineered for the modular \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eAdvantys STB\u003c\/b\u003e\u003c\/font\u003e distributed I\/O architecture. Designed for industrial temperature and low-level voltage acquisition, this flexible module processes RTD, thermocouple (TC), and millivolt (±80 mV) signals across two individually configurable channels, making it a staple in distributed PLC nodes and process islands.\u003c\/p\u003e\n\u003cp\u003eBuilt with 15-bit plus sign resolution and robust 1500V AC field-to-bus galvanic isolation, the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eSTBART0200\u003c\/b\u003e\u003c\/font\u003e protects upstream control processors from high-voltage transient noise. Its hot-swapping capability allows technicians to replace faulty modules on energized backplanes without shutting down the entire PLC rack.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eTechnical Parameter Breakdown Matrix\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eManufacturer \u0026amp; Series\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cfont color=\"#0056b3\"\u003e\u003cb\u003eSchneider Electric\u003c\/b\u003e\u003c\/font\u003e \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eAdvantys STB\u003c\/b\u003e\u003c\/font\u003e Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eExact Part Number\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cfont color=\"#0056b3\"\u003e\u003cb\u003eSTBART0200\u003c\/b\u003e\u003c\/font\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eModule Type \u0026amp; Channels\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard Analog Input Module (RTD \/ TC \/ mV); \u003cb\u003e2 Individually Configurable Channels\u003c\/b\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eSupported Sensor Inputs\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cb\u003eRTD:\u003c\/b\u003e Pt100, Pt1000, Ni100, Ni1000, Cu10 (2-, 3-, and 4-wire)\u003cbr\u003e\u003cb\u003eThermocouple:\u003c\/b\u003e Types B, E, J, K, R, S, T\u003cbr\u003e\u003cb\u003eLow-Level Voltage:\u003c\/b\u003e ±80 mV DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eConversion Resolution\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cb\u003e15 bits + sign\u003c\/b\u003e (high-accuracy digital conversion)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eOvervoltage Protection\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eMaximum allowable input up to \u003cb\u003e±7.5V DC\u003c\/b\u003e without permanent damage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eGalvanic Isolation\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cb\u003e1500V AC\u003c\/b\u003e field-to-bus isolation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eElectrical Power Supply\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cb\u003e24V DC\u003c\/b\u003e nominal via Power Distribution Module (PDM model \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eSTBPDT3100\u003c\/b\u003e\u003c\/font\u003e)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eBackplane Base \u0026amp; Width\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eRequires \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eSTBXBA1000\u003c\/b\u003e\u003c\/font\u003e I\/O base (ultra-slim \u003cb\u003e13.9 mm\u003c\/b\u003e footprint)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eEnvironmental Ratings\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eOperating temperature \u003cb\u003e0°C to 60°C (32°F to 140°F)\u003c\/b\u003e; Storage -40°C to +85°C; \u003cb\u003eIP20\u003c\/b\u003e enclosure\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cb\u003eMechanical Installation \u0026amp; Bus Integration Protocol\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eBase Mounting:\u003c\/b\u003e Snap the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eSTBART0200\u003c\/b\u003e\u003c\/font\u003e directly onto the 13.9 mm \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eSTBXBA1000\u003c\/b\u003e\u003c\/font\u003e standard I\/O base mounted on the DIN rail.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003ePower Distribution:\u003c\/b\u003e Ensure the adjacent Power Distribution Module (\u003cfont color=\"#0056b3\"\u003e\u003cb\u003eSTBPDT3100\u003c\/b\u003e\u003c\/font\u003e) supplies clean 24V DC sensor-bus voltage to the island segment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eHot-Swap Execution:\u003c\/b\u003e Slide the locking latches to unseat the module during live maintenance without interrupting the local island bus or neighboring I\/O cards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eField Wiring Shielding:\u003c\/b\u003e Terminate thermocouple extension wires and 3\/4-wire RTD shields to the base grounding terminals to eliminate electromagnetic interference (EMI).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eInstrumentation Commissioning \u0026amp; Configuration Guidelines\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eSoftware Setup:\u003c\/b\u003e Use Advantys configuration software (or SoMove \/ EcoStruxure) to independently configure each channel for RTD curve matching or cold-junction compensated thermocouple inputs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eLead Resistance Compensation:\u003c\/b\u003e When deploying 2-wire RTDs, input cable resistance offsets into the register configuration to maintain sub-degree temperature accuracy.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eDiagnostic Polling:\u003c\/b\u003e Monitor input status bits for open-circuit detection, over-range faults, and sensor burn-out conditions during initial loop checkouts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eLifecycle \u0026amp; System Modernization Path\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eLegacy Status:\u003c\/b\u003e The \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eAdvantys STB\u003c\/b\u003e\u003c\/font\u003e line has been largely superseded by the advanced \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eModicon X80\u003c\/b\u003e\u003c\/font\u003e and Modicon M580 PAC platforms for new greenfield installations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eSustaining Maintenance:\u003c\/b\u003e Original replacement modules remain critical for maintaining legacy distributed I\/O drops without forcing expensive backplane rewiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003ePackage Contents \u0026amp; Fulfillment Specs\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eCondition:\u003c\/b\u003e Brand new and original in factory packaging with protective terminal covers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eWarranty:\u003c\/b\u003e Covered by a comprehensive 12-month industrial automation warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eEngineering Field Guide \u0026amp; Selection FAQ\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ: Can I mix a Pt100 RTD on channel 1 and a Type K thermocouple on channel 2 simultaneously?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Each of the two channels on the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eSTBART0200\u003c\/b\u003e\u003c\/font\u003e is independently configurable in software, allowing mixed sensor types across the same module.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: What causes unstable temperature readings or fluctuating millivolt values on thermocouple inputs?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Unstable readings usually stem from ungrounded thermocouple shields picking up plant inverter noise or missing cold-junction compensation references. Verify shield grounding and ensure thermocouple extension wire matches the probe alloy.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: How does hot-swapping the STBART0200 affect the broader Advantys STB island?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Because the island backplane maintains communication through the Network Interface Module (NIM), unsealing and replacing this module does not drop the communication bus or affect healthy neighboring I\/O.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: Do I need a separate terminal base when ordering a replacement module?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module ships as an electronic insert. If your existing \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eSTBXBA1000\u003c\/b\u003e\u003c\/font\u003e base is undamaged, you can plug the new unit directly into the existing base without rewiring field cables.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: Why is 4-wire RTD configuration recommended over 2-wire for long cable runs?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: 4-wire measurement completely eliminates lead-wire resistance errors caused by ambient temperature changes across long cable distances, ensuring maximum precision in critical process monitoring.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":68083550650550,"sku":"STBART0200","price":119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/STBART0200-1.jpg?v=1794897765","url":"https:\/\/www.plcsparehub.com\/products\/stbart0200-2-channel-rtd-tc-mv-module-schneider-electric-advantys-stb","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}