{"product_id":"spipt800-infi-net-to-pn800-module-by-abb-symphony-plus","title":"SPIPT800 INFI-Net to PN800 Module by ABB – Symphony Plus","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview – Network Transfer Function\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eABB SPIPT800\u003c\/strong\u003e\u003c\/span\u003e is an INFI-Net to PN800 transfer module for ABB Symphony Plus control systems. It provides bidirectional communication between the INFI-Net control network and the PN800 Plant Network.\u003c\/p\u003e\n\u003cp\u003eThe module transfers exception reports, control data, and configuration data through TCP\/IP over Ethernet. It allows compatible network segments to exchange control information without replacing the existing INFI-Net infrastructure.\u003c\/p\u003e\n\u003cp\u003eIn system integration projects, the SPIPT800 supports communication between legacy INFI-Net installations and PN800-based network architecture. Engineers can use it as part of a staged network migration or an existing plant network interface arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Architecture – What the Module Connects\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eINFI-Net side:\u003c\/strong\u003e Connects the existing INFI-Net control network to the transfer interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePN800 side:\u003c\/strong\u003e Exchanges network data with the PN800 Plant Network through Ethernet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData transfer:\u003c\/strong\u003e Passes exception reports, control information, and configuration data in both directions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication protocol:\u003c\/strong\u003e Uses TCP\/IP over Ethernet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet channels:\u003c\/strong\u003e CH 0 and CH 1 support 10\/100 Mbps communication.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SPIPT800 performs network-level data transfer. It should not be treated as a direct substitute for a controller, process I\/O module, or standalone Ethernet switch.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eSPIPT800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eSymphony Plus – HR Series Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eINFI-Net to PN800 Transfer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eBidirectional network data transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interfaces\u003c\/td\u003e\n\u003ctd\u003eINFI-Net and PN800 Plant Network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP over Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Channels\u003c\/td\u003e\n\u003ctd\u003eCH 0 and CH 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Rate\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e64 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNVRAM\u003c\/td\u003e\n\u003ctd\u003e2 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eROM\u003c\/td\u003e\n\u003ctd\u003e4 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e+5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Current\u003c\/td\u003e\n\u003ctd\u003e1.05 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Power Consumption\u003c\/td\u003e\n\u003ctd\u003e5.25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 250 nodes per INFI-Net loop or PN800 network segment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum System Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 250 network segments and 62,500 nodes total, subject to system configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (32°F to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Integration – Application and Engineering Value\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SPIPT800 is relevant when a plant needs to maintain communication between an existing INFI-Net installation and a PN800 network.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork migration:\u003c\/strong\u003e Supports communication during a phased transition toward PN800 network infrastructure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl data exchange:\u003c\/strong\u003e Transfers control and configuration information between the two network environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eException reporting:\u003c\/strong\u003e Carries exception reports across the network interface for system monitoring and event handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge network architecture:\u003c\/strong\u003e Supports network configurations with multiple loops or segments, subject to the system design limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlant expansion:\u003c\/strong\u003e Provides a communication interface when integrating compatible network segments into an existing control system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBefore implementation, engineers should confirm the installed controller architecture, network topology, firmware compatibility, and the required interface hardware. Ethernet link speed alone does not establish end-to-end communication compatibility.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRelated Interface Kit – SPIEB800K02\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSPIEB800K02\u003c\/strong\u003e\u003c\/span\u003e is the related INFI-Net to PN800 Plant Network interface bundled kit. It includes the modules, termination units, cables, and mounting hardware required for the specified interface arrangement.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eKit Quantity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPIPT800\u003c\/td\u003e\n\u003ctd\u003eINFI-Net to Plant Network transfer module\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPNIS21\u003c\/td\u003e\n\u003ctd\u003eNetwork interface module\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNKLS01-10\u003c\/td\u003e\n\u003ctd\u003eCommunication module cable\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNTCL01\u003c\/td\u003e\n\u003ctd\u003eCommunication termination unit\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEMMU21\u003c\/td\u003e\n\u003ctd\u003eModule mounting unit\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNFTP01\u003c\/td\u003e\n\u003ctd\u003eField termination panel\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePBA800\u003c\/td\u003e\n\u003ctd\u003eProcess bus adaptor 800\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTER800\u003c\/td\u003e\n\u003ctd\u003eHN800\/CW800 bus terminator\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPK800-RCL1\u003c\/td\u003e\n\u003ctd\u003eBridge redundancy cable\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering note:\u003c\/strong\u003e SPIPT800 is the individual transfer module. SPIEB800K02 is the complete bundled interface kit. Confirm the required scope before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Commissioning Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the hardware identity:\u003c\/strong\u003e Confirm the SPIPT800 model number and hardware revision against the installed system documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the mounting arrangement:\u003c\/strong\u003e Check the required mounting unit, termination hardware, and cable connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the power source:\u003c\/strong\u003e Verify the +5 VDC supply and available current capacity before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect Ethernet connections:\u003c\/strong\u003e Confirm CH 0 and CH 1 assignments, cable condition, and network-side settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidate network configuration:\u003c\/strong\u003e Check IP addressing, TCP\/IP settings, network topology, and communication parameters against the approved project configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest data exchange:\u003c\/strong\u003e Verify exception reports, control data, and configuration transfer in both directions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecord the results:\u003c\/strong\u003e Document module identity, network settings, communication status, and commissioning observations.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eDo not change live network settings without an approved maintenance procedure. A configuration mismatch can interrupt communication between connected control networks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMaintenance and Fault Isolation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication interruption:\u003c\/strong\u003e Check Ethernet cabling, port assignments, network availability, and configuration consistency before replacing the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntermittent data transfer:\u003c\/strong\u003e Review network errors, connection stability, and the condition of associated interface components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower-related symptoms:\u003c\/strong\u003e Measure the +5 VDC supply under operating conditions and check for voltage instability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork expansion:\u003c\/strong\u003e Recalculate node and segment counts before adding another network connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule replacement:\u003c\/strong\u003e Record the original hardware revision and configuration details before removing the installed unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eReplacing a transfer module does not automatically correct a network-side fault. Check the connected interface hardware and network configuration as part of the same diagnostic process.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can an SPIPT800 replacement be installed without changing the existing INFI-Net configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Not automatically. A replacement may retain the existing network design, but engineers should verify the module revision, interface arrangement, firmware requirements, and configured network parameters. Record the existing settings before removing the original module. This reduces the risk of introducing a second fault during replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What should engineers check when Ethernet communication is available but control data does not transfer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: A physical Ethernet link does not prove that the network bridge is exchanging valid control data. Check TCP\/IP configuration, network addressing, routing or segment settings, and the status of both connected network sides. Then test exception reports and control data separately. This helps distinguish a link-layer problem from a configuration or application-level issue.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does a 100 Mbps Ethernet connection guarantee the full 62,500-node system capacity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The published capacity describes the supported network scale, not guaranteed throughput under every operating condition. Actual performance depends on network topology, traffic volume, connected equipment, and system configuration. Review the project network design before using the maximum node count as a planning target.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Should a plant order SPIPT800 or the SPIEB800K02 kit for a network expansion?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Choose SPIPT800 when the project requires the individual transfer module and the remaining interface hardware is already available. Choose SPIEB800K02 when the specified bundled interface components are also required. Check the installed inventory first. Ordering the module alone may leave the project without the necessary termination or mounting components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What information should be collected before requesting a replacement quotation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Provide the full model number, hardware revision, quantity, installed system series, and a clear photo of the module nameplate. If possible, include the related interface-kit number and the nature of the communication fault. These details help confirm the correct item and reduce the risk of selecting an incompatible network component.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68128907296950,"sku":"SPIPT800","price":106.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/SPIPT800-1.jpg?v=1795420950","url":"https:\/\/www.plcsparehub.com\/products\/spipt800-infi-net-to-pn800-module-by-abb-symphony-plus","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}