{"product_id":"sk-050-keyence-in-line-type-sensor-head-sk-series-charge-ion-meter","title":"SK-050 Keyence In-Line Type Sensor Head | SK Series Charge \u0026 Ion Meter","description":"\u003ch3\u003eCore Product Architecture\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eSK-050\u003c\/span\u003e\u003c\/strong\u003e is an advanced in-line electrostatic sensor head engineered by \u003cstrong\u003e\u003cspan style=\"color: #2b303a;\"\u003eKeyence\u003c\/span\u003e\u003c\/strong\u003e within the specialized \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eSK\u003c\/span\u003e\u003c\/strong\u003e series. It provides dual-mode charge potential monitoring alongside ambient temperature and humidity tracking. Global PLC Spare HUB's Insight emphasizes that deploying electrostatic sensors directly above critical web paths allows engineers to intercept static accumulation before electrostatic discharge damages sensitive electronic microcircuits.\u003c\/p\u003e\n\n\u003ch3\u003eComprehensive Technical Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer \/ Brand:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #2b303a;\"\u003eKeyence\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel \u0026amp; Series:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eSK-050\u003c\/span\u003e\u003c\/strong\u003e (\u003cspan style=\"color: #0056b3;\"\u003eSK\u003c\/span\u003e Series In-Line Type Sensor Head)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Modes:\u003c\/strong\u003e High-precision mode and wide-range mode\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReference \u0026amp; Measuring Distance:\u003c\/strong\u003e High-precision mode covers 5 to 50 mm (reference at 25 mm); wide-range mode covers 60 to 120 mm (reference at 100 mm)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePotential Measuring Range:\u003c\/strong\u003e ±2 kV (high-precision) up to ±50 kV (wide-range)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePotential Measuring Accuracy:\u003c\/strong\u003e ±10 V (high-precision); ±100 V (wide-range)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSampling Cycle:\u003c\/strong\u003e Approx. 1.4 ms for static potential; 1 s for environmental metrics\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Metrics:\u003c\/strong\u003e Temperature range of 0 to 50°C (±1°C accuracy); relative humidity of 10 to 85% RH (±5% RH accuracy)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIon Balance Capability:\u003c\/strong\u003e Measuring range of ±1 kV with ±10 V accuracy and 1 V display resolution\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhysical Build:\u003c\/strong\u003e PC body case, SUS metal parts, and PVC cable weighing approx. 35 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation and Mechanical Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePosition the sensor head strictly within the defined 5 to 50 mm or 60 to 120 mm envelope depending on target voltage intensity.\u003c\/li\u003e\n  \u003cli\u003eSecure the lightweight 35 g unit using vibration-damped mounting brackets to eliminate structural sway.\u003c\/li\u003e\n  \u003cli\u003eRoute the flexible PVC cable safely away from high-voltage power lines to prevent electromagnetic induction noise.\u003c\/li\u003e\n  \u003cli\u003eVerify that ambient shop floor conditions remain free of liquid water condensation to protect internal optics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommissioning and Maintenance Protocol\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePerform initial zero-adjustment calibration under uncharged baseline conditions using the main controller interface.\u003c\/li\u003e\n  \u003cli\u003eInspect the optical aperture periodically for dust films that could attenuate incoming electrostatic field readings.\u003c\/li\u003e\n  \u003cli\u003eClean sensor windows gently with isopropyl alcohol wipes if airborne particulate accumulation causes signal drift.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSystem Compatibility and Compliance\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned for direct hardware integration with Keyence modular static elimination controller platforms.\u003c\/li\u003e\n  \u003cli\u003eConstructed from industrial-grade polycarbonate and stainless steel components for chemical durability.\u003c\/li\u003e\n  \u003cli\u003eComplies with standard electrical safety limits for low-voltage industrial instrumentation enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePackage Contents and Warranty Policy\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOne \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eSK-050\u003c\/span\u003e\u003c\/strong\u003e electrostatic sensor head unit\u003c\/li\u003e\n  \u003cli\u003eIntegrated PVC connecting cable\u003c\/li\u003e\n  \u003cli\u003eComprehensive 12-month replacement warranty backed by Global PLC Spare HUB\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eGlobal Logistics and Shipping Terms\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRigid protective packaging ensures safe international delivery for delicate instrumentation.\u003c\/li\u003e\n  \u003cli\u003eExpress global dispatch handled via trusted couriers including \u003cstrong\u003eFedEx, UPS, and DHL\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eGuaranteed order processing and shipment turnaround within \u003cstrong\u003e24 to 48 hours\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTarget Equipment, Applications, and Diagnostics\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTarget Equipment:\u003c\/strong\u003e Semiconductor wafer handlers, film converting lines, high-speed printers, and electronic assembly conveyors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplications:\u003c\/strong\u003e Real-time surface static monitoring, ionizer performance verification, and cleanroom environmental tracking.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiagnostic Capabilities:\u003c\/strong\u003e Detects sudden static spikes and ion imbalance trends instantly, giving engineers actionable data to prevent ESD component failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSelection Guidelines and Expert Advice\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSelect the high-precision mode configuration when monitoring delicate semiconductor surfaces requiring tight ±10 V accuracy thresholds.\u003c\/li\u003e\n  \u003cli\u003eOpt for wide-range placement if your process handles heavy web charging up to ±50 kV on high-speed plastic film lines.\u003c\/li\u003e\n  \u003cli\u003eAccount for local ambient humidity fluctuations since extreme dry air shifts static generation rates drastically.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary operational difference between the high-precision and wide-range modes on the \u003cspan style=\"color: #0056b3;\"\u003eSK-050\u003c\/span\u003e?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: High-precision mode operates at closer distances (5 to 50 mm) to capture micro-voltages up to ±2 kV, whereas wide-range mode extends distances up to 120 mm to measure heavy charges reaching ±50 kV.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How does the integrated temperature and humidity tracking assist line engineers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It correlates environmental shifts with static build-up trends, helping technicians identify when dry shop floor air is amplifying electrostatic risks.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What field troubleshooting steps should I take if potential readings become erratic?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Field experience indicates that erratic signals usually stem from contaminated sensor windows or grounding loops on the PVC cable shield; inspect both elements first.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can this sensor evaluate neutralizing performance from standalone static eliminators?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The dedicated ion balance measuring mode checks residual offset voltages down to ±1 kV to verify bar performance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How should I choose the mounting standoff distance for optimal data capture?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Reference distances of 25 mm for precision mode and 100 mm for wide-range mode provide the most linear response curves according to calibration standards.\u003c\/p\u003e","brand":"Keyence","offers":[{"title":"Default Title","offer_id":47537741004982,"sku":"SK-050","price":46.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/SK-050-3.jpg?v=1789975509","url":"https:\/\/www.plcsparehub.com\/products\/sk-050-keyence-in-line-type-sensor-head-sk-series-charge-ion-meter","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}