{"product_id":"sick-s30b-2011ca-safety-scanner-s300-advanced-series-2m-8m-field","title":"SICK S30B-2011CA Safety Scanner S300 Advanced Series 2m\/8m Field","description":"\u003ch3\u003e\u003cstrong\u003eProduct Introduction\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSICK \u003cspan style=\"color: #ff0000;\"\u003eS30B-2011CA\u003c\/span\u003e\u003c\/strong\u003e is a cornerstone of the S300 Advanced series, providing reliable Type 3 safety laser scanning for complex industrial environments. Engineered for indoor applications, it features a \u003cstrong\u003e2-meter protective field\u003c\/strong\u003e and an expansive \u003cstrong\u003e8-meter warning field\u003c\/strong\u003e within a 270° scanning arc. This \"Advanced\" variant is specifically designed for integration into safety clusters via EFI (Enhanced Function Interface), allowing for decentralized safety logic and synchronized field switching across multiple SICK devices.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEngineering Hierarchy: Suffix \u0026amp; System Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003e\u003cspan style=\"color: #ff0000;\"\u003eS30B-2011CA\u003c\/span\u003e\u003c\/strong\u003e — S300 Advanced Security Core\n        \u003cul style=\"list-style-type: none;\"\u003e\n            \u003cli\u003e└─ \u003cstrong\u003eOptical Hub\u003c\/strong\u003e: 905 nm Pulsed Laser (Class 1 Eye-Safe)\u003c\/li\u003e\n            \u003cli\u003e└─ \u003cstrong\u003eField Management\u003c\/strong\u003e: 4 Triple Field Sets (12 Total Monitored Fields)\u003c\/li\u003e\n            \u003cli\u003e└─ \u003cstrong\u003eSafe Communication\u003c\/strong\u003e: EFI (Enhanced Function Interface) for Device Clustering\u003c\/li\u003e\n            \u003cli\u003e└─ \u003cstrong\u003eInterface Logic\u003c\/strong\u003e: RS-232 Configuration \/ RS-422 Data Interface\u003c\/li\u003e\n            \u003cli\u003e└─ \u003cstrong\u003eBuild Variant\u003c\/strong\u003e: Sensor Head Only (System plug required for operation)\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e \u003cstrong\u003eSICK\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #ff0000;\"\u003eS30B-2011CA\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e SIL 2 (IEC 61508) \/ PL d (EN ISO 13849) \/ Type 3\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProtective Range:\u003c\/strong\u003e 2.0 Meters (Configurable 30mm to 70mm resolution)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWarning Range:\u003c\/strong\u003e 8.0 Meters (@ 15% reflectivity)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eScanning Angle:\u003c\/strong\u003e 270° Wide-angle\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 80 ms (Configurable via multiple sampling)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e 1 OSSD Pair (2 x 250 mA) \/ 3 Diagnostic Outputs\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e IP65 (Aluminum Die-cast \/ Polycarbonate Optics)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 102 mm x 152 mm x 106 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #ff0000;\"\u003eS30B-2011CA\u003c\/span\u003e\u003c\/strong\u003e is the \"Compact Integrator's Choice.\" While newer models offer larger ranges, the S300 Advanced remains essential due to its \u003cstrong\u003eEFI capability\u003c\/strong\u003e. This allows field engineers to link two scanners on an AGV or robotic cell so they \"talk\" to each other without needing a separate safety PLC for basic field switching. From an engineering perspective, the 80ms response time is exceptionally stable, and the triple-field set configuration (1 protective, 2 warning) provides a more nuanced approach to machine deceleration compared to standard dual-field scanners.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTarget Equipment \u0026amp; Diagnostic Power\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIdeal Equipment:\u003c\/strong\u003e Small to medium AGVs, mobile service robots, robotic palletizing cells, and automated material transfer stations.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDiagnostic Power:\u003c\/strong\u003e Utilizes SICK's CDS (Configuration and Diagnostic Software) via RS-232. The scanner provides 3 application diagnostic outputs for real-time status signaling (e.g., \"Optics Dirty\" or \"Warning Field Interrupted\").\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnvironment Adaptation:\u003c\/strong\u003e 100mm protective field supplement and multiple sampling settings (up to 16x) allow the scanner to ignore environmental noise like welding sparks or heavy dust.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCommercial Logistics \u0026amp; Quality\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e New \u0026amp; Original (Sensor unit; requires existing or new system plug)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e \u003cstrong\u003e12 Months Comprehensive Factory Warranty\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDispatch Window:\u003c\/strong\u003e Ships within 24-48 hours\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExpress Global Shipping:\u003c\/strong\u003e Fast delivery via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, or \u003cstrong\u003eDHL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQ (Field Engineering \u0026amp; Selection)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\u003cstrong\u003eQ: Does the \u003cspan style=\"color: #ff0000;\"\u003eS30B-2011CA\u003c\/span\u003e come with the system plug for wiring?\u003c\/strong\u003e\u003c\/li\u003e\n    \u003cli\u003eA: No. This specific model is the \"Sensor without system plug.\" In S300 series architecture, the wiring and configuration memory reside in the system plug. If this is a new installation, you must purchase the appropriate system plug separately; if it is a replacement, you can simply mount this sensor to your existing plug.\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003eQ: How does the multiple sampling (2 ... 16) affect machine safety distance?\u003c\/strong\u003e\u003c\/li\u003e\n    \u003cli\u003eA: Increasing the sampling count improves resistance to nuisance trips (like dust) but increases the total response time. For every additional sample, you must recalculate the safety distance according to ISO 13855 to ensure the machine stops before the hazard is reached.\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003eQ: Can I use the \u003cspan style=\"color: #ff0000;\"\u003eS30B-2011CA\u003c\/span\u003e to synchronize fields with a SICK Flexi Soft system?\u003c\/strong\u003e\u003c\/li\u003e\n    \u003cli\u003eA: Absolutely. By using the EFI interface, the scanner can communicate directly with a Flexi Soft EFI gateway. This allows the PLC to switch between the 4 field sets based on machine speed, direction, or position data.\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003eQ: Selection Guidance: When should I choose the S300 \"Advanced\" over the \"Basic\" version?\u003c\/strong\u003e\u003c\/li\u003e\n    \u003cli\u003eA: Choose the Advanced version (S30B-2011CA) if you require EFI safe communication, more than 1 field set, or the ability to use triple-field sets. The Basic version is typically restricted to 1 field set and lacks network capabilities.\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003eQ: What is the \"Safe state\" behavior of this scanner during a fatal internal error?\u003c\/strong\u003e\u003c\/li\u003e\n    \u003cli\u003eA: In accordance with Type 3 safety standards, if the scanner detects an internal fault or the optics are completely blocked, it will force at least one OSSD into the OFF state, ensuring the connected machine enters a safe stop condition.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SICK","offers":[{"title":"Default Title","offer_id":45091672293558,"sku":"SICK S30B-2011CA","price":268.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/S30B-2011CA.jpg?v=1777280014","url":"https:\/\/www.plcsparehub.com\/products\/sick-s30b-2011ca-safety-scanner-s300-advanced-series-2m-8m-field","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}