{"product_id":"sec-z732mgx-horiba-stec-sec-z700x-100slm-mfc","title":"SEC-Z732MGX HORIBA STEC SEC-Z700X 100SLM MFC","description":"\u003ch3\u003e\u003cstrong\u003eEngineering Architecture \u0026amp; Performance Profile\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003eSEC-Z732MGX\u003c\/strong\u003e\u003c\/span\u003e is a high-precision, pressure-insensitive mass flow controller belonging to HORIBA STEC’s advanced \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003eSEC-Z700X\u003c\/strong\u003e\u003c\/span\u003e series. Engineered for large Chemical Vapor Deposition (CVD) chambers and high-capacity bulk gas delivery panels, this instrument neutralizes upstream pressure transients to deliver flawless flow stability under rigorous industrial operating conditions.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eMetrological \u0026amp; Operational Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdl\u003e\n  \u003cdt\u003e\u003cstrong\u003eBrand \u0026amp; Series\u003c\/strong\u003e\u003c\/dt\u003e\n  \u003cdd\u003eHORIBA STEC | \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003eSEC-Z700X\u003c\/strong\u003e\u003c\/span\u003e Series\u003c\/dd\u003e\n  \u003cdt\u003e\u003cstrong\u003eExact Model\u003c\/strong\u003e\u003c\/dt\u003e\n  \u003cdd\u003e\u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003eSEC-Z732MGX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/dd\u003e\n  \u003cdt\u003e\u003cstrong\u003eFull-Scale Flow Range\u003c\/strong\u003e\u003c\/dt\u003e\n  \u003cdd\u003e100 SLM (N2 equivalent, MR\/MG #09)\u003c\/dd\u003e\n  \u003cdt\u003e\u003cstrong\u003eAccuracy \u0026amp; Linearity\u003c\/strong\u003e\u003c\/dt\u003e\n  \u003cdd\u003e±1.0% S.P. (\u0026gt;35% FS); ±0.35% FS (≤35% FS); Linearity ±0.5% FS\u003c\/dd\u003e\n  \u003cdt\u003e\u003cstrong\u003eRepeatability \u0026amp; Response Time\u003c\/strong\u003e\u003c\/dt\u003e\n  \u003cdd\u003eRepeatability ±0.2% FS; Response time ≤1 second (T98 across full flow range)\u003c\/dd\u003e\n  \u003cdt\u003e\u003cstrong\u003ePressure Parameters\u003c\/strong\u003e\u003c\/dt\u003e\n  \u003cdd\u003eOperating differential: 100–300 kPa(d); Max operating: 450 kPa(g); Pressure resistance: 1000 kPa(g)\u003c\/dd\u003e\n  \u003cdt\u003e\u003cstrong\u003eWetted Materials \u0026amp; Sealing\u003c\/strong\u003e\u003c\/dt\u003e\n  \u003cdd\u003eSUS316L stainless steel and Co-Ni alloy with electropolished inner finish; metal seals (Leak integrity ≤5×10¹² Pa·m³\/s He)\u003c\/dd\u003e\n  \u003cdt\u003e\u003cstrong\u003eElectrical \u0026amp; Interface\u003c\/strong\u003e\u003c\/dt\u003e\n  \u003cdd\u003eAnalog 0.1–5 VDC setpoint \/ 0–5 VDC output; RS-485 F-Net protocol; D-Sub 9-pin and RJ-45 ports\u003c\/dd\u003e\n  \u003cdt\u003e\u003cstrong\u003ePhysical Dimensions \u0026amp; Power\u003c\/strong\u003e\u003c\/dt\u003e\n  \u003cdd\u003e139×70×38 mm (H×W×T), 1\/2\" VCR fittings, 132 mm fitting distance; Power ±15 VDC ±5% (165 mA)\u003c\/dd\u003e\n\u003c\/dl\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePneumatic Integration \u0026amp; Installation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMaintain cleanroom protocols when securing the 1\/2\" VCR metal seal fittings to prevent particulate contamination.\u003c\/li\u003e\n  \u003cli\u003eEnsure upstream supply pressures maintain a differential pressure window strictly between 100 and 300 kPa(d) for optimal pressure compensation.\u003c\/li\u003e\n  \u003cli\u003eVerify pinout configurations on the D-Sub 9-pin and RJ-45 connectors prior to energizing the unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCommissioning, Calibration \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUtilize the RS-485 F-Net digital interface to execute multi-gas profile selections (MR\/MG #09) and monitor zero stability.\u003c\/li\u003e\n  \u003cli\u003ePerform periodic helium mass spectrometer leak tests to verify seal integrity in high-cycle gas panels.\u003c\/li\u003e\n  \u003cli\u003eClean exterior surfaces with approved semiconductor-grade solvents during scheduled maintenance shutdowns.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility \u0026amp; Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis unit is fully compatible with modern PLC and DCS architectures supporting RS-485 F-Net protocols or standard analog 0–5 VDC I\/O. Built in strict accordance with SEMI standards and RoHS directives, the unheated standard design integrates seamlessly into existing high-flow gas boxes.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePacking List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOne \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003eSEC-Z732MGX\u003c\/strong\u003e\u003c\/span\u003e Mass Flow Controller Unit\u003c\/li\u003e\n  \u003cli\u003eFactory Calibration and Compliance Certificate\u003c\/li\u003e\n  \u003cli\u003eTechnical Documentation and Pinout Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProcurement \u0026amp; Selection Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConfirm your maximum gas flow requirements match the 100 SLM full-scale capacity.\u003c\/li\u003e\n  \u003cli\u003eVerify that your gas delivery manifold accommodates 1\/2\" VCR connection spacing (132 mm fitting distance).\u003c\/li\u003e\n  \u003cli\u003eSpecify whether analog or digital F-Net communication aligns with your control infrastructure before requesting a quote.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eAdvanced Engineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the integrated pressure sensor inside the \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003eSEC-Z732MGX\u003c\/strong\u003e\u003c\/span\u003e compensate for line pressure drops?\u003c\/strong\u003e\u003cbr\u003e\nA: The on-board pressure sensor continuously monitors upstream pressure transients and feeds real-time correction data to the piezoelectric actuator, neutralizing flow overshoots during chamber purging cycles.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Why is electropolished SUS316L combined with a Co-Ni alloy utilized for wetted parts?\u003c\/strong\u003e\u003cbr\u003e\nA: Electropolishing minimizes surface micro-roughness to prevent moisture and impurity entrapment, while the Co-Ni alloy offers exceptional elastic resilience and fatigue resistance for the fast-acting control valve.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can process engineers switch between different gas types (such as N2, Ar, H2, and He) without breaking vacuum lines?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, the multi-gas architecture allows digital switching between pre-calibrated gas curves via the RS-485 interface without requiring physical removal from the VCR manifold.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What occurs if the operating differential pressure drops below the 100 kPa(d) threshold?\u003c\/strong\u003e\u003cbr\u003e\nA: Operating below 100 kPa(d) restricts the pressure drop required across the control valve, reducing the regulatory authority of the piezo actuator and degrading dynamic flow accuracy.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What diagnostic steps are recommended if zero-point drift is observed during operation?\u003c\/strong\u003e\u003cbr\u003e\nA: Isolate the gas line using upstream\/downstream shutoff valves, verify thermal stabilization within the 15–45°C recommended range, and re-zero the device via the digital or analog control interface.\u003c\/p\u003e","brand":"HORIBA","offers":[{"title":"Default Title","offer_id":68077536182454,"sku":"SEC-Z732MGX","price":116.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/SEC-Z732MGX.jpg?v=1794798379","url":"https:\/\/www.plcsparehub.com\/products\/sec-z732mgx-horiba-stec-sec-z700x-100slm-mfc","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}