{"product_id":"sec-n100-horiba-stec-digital-mass-flow-controller-sec-n100-gas-delivery","title":"SEC-N100 HORIBA STEC Digital Mass Flow Controller | SEC-N100 Gas Delivery","description":"\u003ch3\u003e\u003cstrong\u003eEngineering Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eHORIBA STEC SEC-N100\u003c\/strong\u003e digital mass flow controller provides precision gas delivery for advanced semiconductor tools and research panels. Driven by a fast piezoelectric actuator, this compact \u003cstrong style=\"color: #0056b3;\"\u003eSEC-N100\u003c\/strong\u003e module delivers stable control across multi-gas profiles from 10 SCCM up to 1000 SLM. Built with electropolished SUS316L wetted parts, it guarantees ultra-clean performance in high-purity environments.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePerformance Matrix \u0026amp; Technical Specs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003e\u003cstrong\u003eTechnical Parameter\u003c\/strong\u003e\u003c\/th\u003e\n      \u003cth\u003e\u003cstrong\u003eEngineering Specification\u003c\/strong\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBrand \u0026amp; Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003eHORIBA STEC\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003eSEC-N100\u003c\/strong\u003e Digital MFC Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Identifier\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003eSEC-N100\u003c\/strong\u003e (Configurable by sub-model N112 to N172)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFull-Scale Flow Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSelectable from 10 SCCM to 1000 SLM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e±1.0% Setpoint (S.P.)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRepeatability \u0026amp; Linearity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRepeatability: ±0.2% FS | Linearity: ±0.5% FS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e≤1 second (Settling time to within ±2% FS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Turndown Ratio\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2% to 100% of Full Scale\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Pressure Bounds\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDifferential: 50–300 kPa(d) | Max Working: 450 kPa(g)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGas Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMulti-gas capability (N2, Ar, H2, He, O2, and process gases)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWetted Materials \u0026amp; Seals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSUS316L stainless steel (mirror polished inner surface) with Metal\/Elastomer seals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLeak Integrity Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e≤5×10\u003csup\u003e-12\u003c\/sup\u003e Pa·m³\/s (Helium leak tested)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Communication\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard RS-485 F-Net (38,400 bps); optional DeviceNet, CC-Link, PROFIBUS-DP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Power Specs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e±15 VDC (±5%) 150\/200 mA (RS-485) or DC 24V 4.0–7.5 VA (bus variants)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThermal Operating Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5°C to 50°C ambient (optimized at 15°C–45°C)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePhysical Integration \u0026amp; Setup Procedure\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVerify Gas Cleanliness:\u003c\/strong\u003e Purge upstream distribution tubing with ultra-high purity nitrogen before mounting the unit.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCheck Orientation:\u003c\/strong\u003e Mount the \u003cstrong style=\"color: #0056b3;\"\u003eSEC-N100\u003c\/strong\u003e horizontally or vertically based on OEM gas box constraints, noting the 106 mm or 124 mm face-to-face fitting span.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque VCR Fittings:\u003c\/strong\u003e Secure metal gasket seals using calibrated wrenches to prevent micro-leaks during thermal cycling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEstablish Bus Wiring:\u003c\/strong\u003e Terminate RS-485 F-Net or fieldbus communication cables, confirming correct shielding ground loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePerform Zero Calibration:\u003c\/strong\u003e Initiate zero-flow auto-tuning via software commands before introducing reactive process media.\u003c\/li\u003e\n\n\n\u003ch3\u003e\u003cstrong\u003eOperational Diagnostics \u0026amp; Servicing Protocol\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePiezo-Actuator Response:\u003c\/strong\u003e The solid-state valve design eliminates thermal drift issues common in traditional thermal solenoid assemblies.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIn-Situ Diagnostics:\u003c\/strong\u003e Monitor valve drive voltage and flow deviation metrics continuously via RS-485 polling registers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePreventive Purging:\u003c\/strong\u003e Flush corrosive residues with inert gas prior to performing system disconnections during scheduled tool overhauls.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEcosystem Compatibility \u0026amp; Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Tool Integration:\u003c\/strong\u003e Drop-in footprint compatible with standard semiconductor gas sticks and gas distribution manifolds.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommunication Interoperability:\u003c\/strong\u003e Seamlessly integrates with PLC platforms supporting F-Net, DeviceNet, CC-Link, or PROFIBUS protocols.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRegulatory Compliance:\u003c\/strong\u003e Fully compliant with RoHS directives and SEMI industry manufacturing standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 × \u003cstrong style=\"color: #0056b3;\"\u003eHORIBA STEC SEC-N100\u003c\/strong\u003e Digital Mass Flow Controller Unit\u003c\/li\u003e\n  \u003cli\u003eFactory calibration data sheet and traceability report\u003c\/li\u003e\n  \u003cli\u003eProtective port caps (pre-installed for shipping isolation)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEngineering Selection Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSpecify sub-model variants (such as N112 for low-flow micro-dosing or N172 for high-capacity utility lines) based on your peak mass flow requirements. Ensure operating differential pressure remains strictly within 50–300 kPa(d) to prevent choked flow or valve saturation anomalies.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How does the piezoelectric valve in the SEC-N100 differ from standard thermal solenoid designs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The piezo actuator utilizes direct crystal displacement rather than magnetic coils, eliminating thermal heat transfer to the flowing gas and drastically accelerating settling times to under one second.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What troubleshooting steps should I take if flow output drifts during multi-gas switching?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Verify that the conversion factor or active gas selection register in the RS-485 controller matches the specific heat capacity and density of the currently injected process gas.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Can this controller maintain stable regulation at the extreme bottom of its control range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes, the unit maintains stable closed-loop regulation down to 2% of full scale, though system designers should ideally size the full-scale flow so normal operating points sit between 30% and 80% FS.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: Why is strict adherence to the 50–300 kPa(d) differential pressure window critical for field operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Insufficient pressure drop starves the control valve authority, while excessive differential pressure forces high gas velocity that can destabilize upstream laminar flow elements.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: What preventive maintenance prevents particulate accumulation inside the internal sensor bypass?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA5: Always maintain downstream inline 0.003-micron metal filters and ensure process gas dew points remain below -70°C to eliminate moisture-induced particulate agglomeration.\u003c\/p\u003e\n\u003c\/ol\u003e","brand":"HORIBA","offers":[{"title":"Default Title","offer_id":68077574783158,"sku":"SEC-N100","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/SEC-N100_3.jpg?v=1794798572","url":"https:\/\/www.plcsparehub.com\/products\/sec-n100-horiba-stec-digital-mass-flow-controller-sec-n100-gas-delivery","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}