{"product_id":"sec-e431x-sec-e-series-horiba-stec-high-flow-gas-controller","title":"SEC-E431X SEC-E Series HORIBA STEC High-Flow Gas Controller","description":"\u003ch3\u003e\u003cstrong\u003eSEC-E431X | High-Flow Economy Gas Control Solution\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1677b8;\"\u003eSEC-E431X\u003c\/span\u003e\u003c\/strong\u003e is an economy-type Mass Flow Controller from the \u003cstrong\u003eHORIBA STEC SEC-E Series\u003c\/strong\u003e. It uses a solenoid valve to regulate high-flow delivery of non-corrosive process gases.\u003c\/p\u003e\n\u003cp\u003eIts nitrogen-equivalent full-scale flow range covers \u003cstrong\u003e50 to 100 SLM\u003c\/strong\u003e. This configuration addresses gas distribution requirements in bulk gas panels and industrial process equipment.\u003c\/p\u003e\n\u003cp\u003eThe controller combines analog voltage control with a normally closed solenoid valve. Its standard unheated construction simplifies integration into compatible gas delivery assemblies. The design emphasizes practical flow regulation, straightforward electrical connections, and economical system configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Product Configuration at a Glance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHORIBA STEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSEC-E431X\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eSEC-E Economy Solenoid Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMass Flow Controller (MFC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-Scale Flow Range\u003c\/td\u003e\n\u003ctd\u003e50–100 SLM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Reference Gas\u003c\/td\u003e\n\u003ctd\u003eNitrogen equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Compatibility\u003c\/td\u003e\n\u003ctd\u003eNon-corrosive gases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Configuration\u003c\/td\u003e\n\u003ctd\u003eStandard unheated version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve Technology\u003c\/td\u003e\n\u003ctd\u003eSolenoid valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve State Without Power\u003c\/td\u003e\n\u003ctd\u003eNormally closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connection\u003c\/td\u003e\n\u003ctd\u003e3\/8-inch Swagelok\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Flow Regulation and Measurement Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSEC-E431X\u003c\/strong\u003e provides a 5–100% FS control range. Its accuracy and repeatability specifications define the expected flow regulation performance.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e±0.5% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e±0.5% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e≤1 second, T98 typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Range\u003c\/td\u003e\n\u003ctd\u003e5–100% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-Scale Flow\u003c\/td\u003e\n\u003ctd\u003e50–100 SLM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Note:\u003c\/strong\u003e Accuracy and repeatability use full-scale references. Evaluate these specifications against the actual operating flow rather than assuming identical percentage-of-reading performance at every setpoint.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Pressure Envelope and Gas Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis instrument targets non-corrosive gas delivery. Engineers must verify gas compatibility and pressure conditions before selecting the unit.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Differential Pressure\u003c\/td\u003e\n\u003ctd\u003e100–300 kPa(d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inlet Pressure\u003c\/td\u003e\n\u003ctd\u003e300 kPa(G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Resistance\u003c\/td\u003e\n\u003ctd\u003e1 MPa(G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Gas Category\u003c\/td\u003e\n\u003ctd\u003eNon-corrosive gases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eDo not interpret the pressure resistance rating as a continuous operating pressure. Keep the inlet and differential pressures within their respective operating limits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Solenoid Valve and Wetted Material Design\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe valve assembly uses an electromagnetic solenoid mechanism. Its normally closed configuration provides a defined valve state when electrical power is removed.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial or Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Wetted Material\u003c\/td\u003e\n\u003ctd\u003eSUS316 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeal Material\u003c\/td\u003e\n\u003ctd\u003eFluorine rubber (Viton)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Material\u003c\/td\u003e\n\u003ctd\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnetic Component\u003c\/td\u003e\n\u003ctd\u003eMagnetic stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeal Options\u003c\/td\u003e\n\u003ctd\u003eFluorine rubber \/ PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve Type\u003c\/td\u003e\n\u003ctd\u003eSolenoid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower-Off Valve State\u003c\/td\u003e\n\u003ctd\u003eNormally closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeak Integrity\u003c\/td\u003e\n\u003ctd\u003e≤1 × 10⁻⁹ Pa·m³\/s (He)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCheck the chemical compatibility of Viton, PTFE, and stainless steel with the selected gas. Do not assume compatibility with corrosive or reactive process media.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Analog Control and Electrical Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe electrical interface uses analog voltage signals. This arrangement supports integration with compatible gas control systems and equipment controllers.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetpoint Signal\u003c\/td\u003e\n\u003ctd\u003e0.25–5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Output Signal\u003c\/td\u003e\n\u003ctd\u003e0–5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connector\u003c\/td\u003e\n\u003ctd\u003eD-Sub connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositive Power Supply\u003c\/td\u003e\n\u003ctd\u003e+15 VDC ±5%, 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNegative Power Supply\u003c\/td\u003e\n\u003ctd\u003e-15 VDC ±5%, 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.9 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eControl Integration Checklist:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the host controller supports the specified analog voltage ranges.\u003c\/li\u003e\n\u003cli\u003eCheck the positive and negative supply rails before connection.\u003c\/li\u003e\n\u003cli\u003eConfirm D-Sub connector pin assignments using the applicable wiring documentation.\u003c\/li\u003e\n\u003cli\u003eCheck signal grounding and cable routing to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eVerify the PLC or equipment controller scaling against the selected full-scale range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Mechanical Dimensions and Piping Interface\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe compact housing supports installation in high-flow gas distribution assemblies. The 3\/8-inch Swagelok connection requires suitable manifold and tubing compatibility.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThickness\u003c\/td\u003e\n\u003ctd\u003e41 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Dimensions\u003c\/td\u003e\n\u003ctd\u003e125 × 86 × 41 mm (H × W × T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitting Distance\u003c\/td\u003e\n\u003ctd\u003e142 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connection\u003c\/td\u003e\n\u003ctd\u003e3\/8-inch Swagelok\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eReserve adequate space for tubing installation and connector access. Check fitting alignment before finalizing the gas panel layout.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Operating Temperature and Installation Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e5–45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy Guaranteed Range\u003c\/td\u003e\n\u003ctd\u003e15–35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeated Configuration\u003c\/td\u003e\n\u003ctd\u003eUnheated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor applications requiring the specified accuracy, maintain the instrument within 15–35°C. Temperature changes outside this guaranteed range may affect measurement performance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Typical Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHORIBA STEC SEC-E431X\u003c\/strong\u003e targets economical, high-flow gas regulation in compatible industrial installations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBulk Gas Panels:\u003c\/strong\u003e Regulates non-corrosive gas distribution across high-flow supply systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemiconductor Gas Delivery:\u003c\/strong\u003e Supports compatible process gas supply configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Gas Cabinets:\u003c\/strong\u003e Provides analog-controlled flow regulation for equipment integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Gas Distribution:\u003c\/strong\u003e Handles selected gases within the specified pressure and material limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Flow Equipment:\u003c\/strong\u003e Supports applications requiring 50–100 SLM nitrogen-equivalent capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Installation and Commissioning Procedure\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eProper installation requires coordinated checks of the gas circuit, electrical supply, and mechanical connections.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the complete model number and full-scale flow configuration.\u003c\/li\u003e\n\u003cli\u003eVerify that the selected gas is non-corrosive and material-compatible.\u003c\/li\u003e\n\u003cli\u003eCheck the inlet pressure and operating differential pressure.\u003c\/li\u003e\n\u003cli\u003eInspect the 3\/8-inch Swagelok connection and tubing compatibility.\u003c\/li\u003e\n\u003cli\u003eConfirm the required 142 mm fitting distance.\u003c\/li\u003e\n\u003cli\u003eConnect the specified positive and negative DC supplies.\u003c\/li\u003e\n\u003cli\u003eWire the analog setpoint and output signals correctly.\u003c\/li\u003e\n\u003cli\u003ePerform the approved gas-line leak test.\u003c\/li\u003e\n\u003cli\u003eApply the setpoint and verify the measured flow response.\u003c\/li\u003e\n\u003cli\u003eConfirm stable operation before releasing the equipment for production.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eUse appropriate high-purity gas handling procedures where required. Follow the equipment manufacturer's instructions for connection, purging, and leak testing.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Maintenance and Troubleshooting Insights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eRoutine maintenance should prioritize gas compatibility, pressure stability, electrical signal quality, and valve operation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow instability:\u003c\/strong\u003e Check inlet pressure, differential pressure, and gas supply stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnexpected zero flow:\u003c\/strong\u003e Verify the setpoint, electrical supply, and normally closed valve state.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncorrect flow indication:\u003c\/strong\u003e Inspect analog output wiring and controller scaling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlow response:\u003c\/strong\u003e Review pressure conditions and process-line restrictions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal leakage:\u003c\/strong\u003e Inspect Swagelok connections and compatible sealing components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature-related deviation:\u003c\/strong\u003e Check whether the installation remains within 15–35°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInvestigate gas contamination and valve condition before adjusting process settings. Avoid unauthorized internal modifications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e11 | Standards and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustry Standards:\u003c\/strong\u003e SEMI standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Configuration:\u003c\/strong\u003e Standard unheated version.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSpecific SEMI standard numbers and individual certification references were not included in the supplied specifications. Confirm the applicable compliance documentation before equipment qualification.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e12 | Engineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why is a normally closed valve useful in gas delivery equipment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe valve closes when electrical power is removed. This provides a defined power-off valve state. Engineers should still evaluate the complete gas system's safety design and required isolation devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How should engineers interpret the 1 MPa pressure resistance rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePressure resistance describes a specified withstand condition, not the normal operating limit. The maximum inlet pressure remains 300 kPa(G). Always distinguish operating pressure from pressure resistance during equipment selection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can this model replace a higher-accuracy mass flow controller directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot without reviewing the process requirements. Its accuracy is ±1% FS, and repeatability is ±0.5% FS. Compare these limits with the original instrument's specifications and the process tolerance before replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What causes different flow readings between two controllers with the same nominal capacity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGas calibration, pressure conditions, installation geometry, and signal scaling can produce different readings. Confirm the actual gas and full-scale configuration. Also check whether both instruments use the same reference conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What should procurement teams verify when sourcing this model for an existing gas panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the full model designation, 50–100 SLM capacity, 3\/8-inch Swagelok connection, fitting distance, and electrical interface. Confirm the normally closed valve configuration and seal materials. These details help avoid mechanical and control-system mismatches.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"HORIBA","offers":[{"title":"Default Title","offer_id":68027793834166,"sku":"SEC-E431X","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/SEC-E431X_1.jpg?v=1794281614","url":"https:\/\/www.plcsparehub.com\/products\/sec-e431x-sec-e-series-horiba-stec-high-flow-gas-controller","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}