{"product_id":"scp451-51-yokogawa-industrial-processor-module","title":"SCP451-51 Yokogawa Industrial Processor Module","description":"\u003ch3\u003e\u003cstrong\u003eYokogawa SCP451-51 Processor Module – Hardware Architecture and Configuration Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #008080;\"\u003eYokogawa SCP451-51\u003c\/span\u003e\u003c\/strong\u003e is an industrial processor module designed for control-system processing and system management. It uses a dual-core ARM Cortex-A9 processor with 2 GB DDR3 SDRAM and 8 GB NAND flash memory.\u003c\/p\u003e\n\u003cp\u003eThe module provides two Ethernet ports, two USB ports, and one RS-232 maintenance interface. Its front-panel switches support processor control, battery backup selection, and maintenance diagnostics.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eSCP451-51\u003c\/strong\u003e suffix identifies a specific hardware configuration. Engineers should confirm the complete model code before ordering or replacing a processor module.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Model Identification and Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCode Element\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eEngineering Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSCP451\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcessor module model\u003c\/td\u003e\n\u003ctd\u003eIdentifies the processor hardware type.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard type\u003c\/td\u003e\n\u003ctd\u003eNo explosion protection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3\u003c\/td\u003e\n\u003ctd\u003eSpecifies the stated environmental protection classification.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration summary:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase model:\u003c\/strong\u003e SCP451 processor module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware option:\u003c\/strong\u003e Standard type without explosion protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental option:\u003c\/strong\u003e ISA Standard G3.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not interpret the standard-type option as an explosion-proof approval. Confirm the complete system installation requirements when selecting equipment for hazardous areas.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Processor Architecture and Memory Resources\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe processor and memory configuration provides the computing resources for control-system processing and management information storage.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHardware Resource\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eEngineering Relevance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eDual-core ARM Cortex-A9\u003c\/td\u003e\n\u003ctd\u003eExecutes processor-level control and system tasks.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDDR3 SDRAM\u003c\/td\u003e\n\u003ctd\u003e2 GB\u003c\/td\u003e\n\u003ctd\u003eProvides working memory for active processing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNAND flash\u003c\/td\u003e\n\u003ctd\u003e8 GB\u003c\/td\u003e\n\u003ctd\u003eProvides non-volatile storage capacity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power consumption\u003c\/td\u003e\n\u003ctd\u003e10 W\u003c\/td\u003e\n\u003ctd\u003eSupports power-budget and thermal calculations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWhen evaluating processor capacity, consider the complete control-system configuration. Memory capacity alone does not establish application compatibility or processing performance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Communication Ports and Maintenance Access\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SCP451-51 provides several physical interfaces for system communication and maintenance.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003cth\u003eQuantity\u003c\/th\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eNetwork communication and system connectivity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eSupported maintenance and peripheral connections.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eSerial maintenance access.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eBefore connecting external equipment, check the system documentation for supported communication functions, cable specifications, and port assignments. The presence of a physical interface does not confirm support for every protocol or peripheral.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Front-Panel Switches and Operational Behavior\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe front-panel switches provide direct access to processor maintenance functions. Incorrect switch positions can affect processor operation or diagnostic indications.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eOperating Guidance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSTART\/STOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStops or restarts the processor CPU.\u003c\/td\u003e\n\u003ctd\u003ePressing the switch stops an operating CPU or restarts a stopped CPU.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery ON\/OFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControls battery backup for management information in storage memory.\u003c\/td\u003e\n\u003ctd\u003eSet to ON during normal operation to enable backup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePORT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControls the maintenance port setting.\u003c\/td\u003e\n\u003ctd\u003eSet to OFF during normal operation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDOMN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDisplays the configured domain number through the STATUS LED.\u003c\/td\u003e\n\u003ctd\u003eSet to OFF during normal operation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSTA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDisplays the configured station number through the STATUS LED.\u003c\/td\u003e\n\u003ctd\u003eSet to OFF during normal operation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFIX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControls negotiation behavior on SCP461\/SCP451 models.\u003c\/td\u003e\n\u003ctd\u003eOFF: Auto. ON: Force. Default: OFF.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSTART\/STOP switch access:\u003c\/strong\u003e The maintenance switch sits inside a small opening beside the START\/STOP marking. Use a non-conductive slender tool with an approximate diameter of 1–2 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance precautions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the processor's current operating state before pressing START\/STOP.\u003c\/li\u003e\n\u003cli\u003eDo not use conductive tools around the front-panel switch opening.\u003c\/li\u003e\n\u003cli\u003eKeep the battery switch ON during normal operation.\u003c\/li\u003e\n\u003cli\u003eRecord the original DIP switch positions before changing maintenance settings.\u003c\/li\u003e\n\u003cli\u003eReturn PORT, DOMN, and STA to OFF after maintenance, as specified.\u003c\/li\u003e\n\u003cli\u003eKeep FIX in its default OFF position unless the system design requires forced negotiation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Electrical and Analog Output Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe supplied specification also lists four output channels with selectable current and voltage ranges. These values require confirmation against the exact hardware documentation before engineers use them for wiring or I\/O design.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSupplied Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput channels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent output ranges\u003c\/td\u003e\n\u003ctd\u003e0–20 mA; 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage output ranges\u003c\/td\u003e\n\u003ctd\u003e0–10 VDC; 1–5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput accuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput resolution\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput-to-ground isolation\u003c\/td\u003e\n\u003ctd\u003e500 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eLoad resistance data as supplied:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0–20 mA: 0–1000 Ω.\u003c\/li\u003e\n\u003cli\u003e4–20 mA: 0–1000 Ω.\u003c\/li\u003e\n\u003cli\u003e0–10 VDC: 0–1 MΩ.\u003c\/li\u003e\n\u003cli\u003e1–5 VDC: 0–1 MΩ.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant configuration check:\u003c\/strong\u003e The supplied data combines processor-module identification with analog output channel specifications. Confirm whether these output specifications belong to the SCP451-51 itself or to an associated I\/O module. Do not use this table as a wiring reference until the hardware assignment is verified.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Environmental and Mechanical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e5–95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e123 × 122 × 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003e10 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration resistance\u003c\/td\u003e\n\u003ctd\u003e2.5 g RMS, 10–500 Hz, random\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock resistance\u003c\/td\u003e\n\u003ctd\u003e10 g, 11 ms, half-sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront-panel protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eMaintain adequate cabinet ventilation and observe the specified temperature and humidity limits. The IP20 rating applies to the front-panel protection specification and does not indicate suitability for direct exposure to water or dust.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Installation, Commissioning, and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eProcessor replacement requires more than a physical fit check. Engineers should verify the hardware revision, system configuration, switch settings, and management-data backup requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePre-installation checks\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the complete SCP451-51 model code and equipment identification.\u003c\/li\u003e\n\u003cli\u003eCheck the target system's hardware compatibility and approved slot assignment.\u003c\/li\u003e\n\u003cli\u003eReview the system procedure for processor shutdown and module replacement.\u003c\/li\u003e\n\u003cli\u003eRecord the existing front-panel switch and DIP switch positions.\u003c\/li\u003e\n\u003cli\u003eCheck the battery backup status before any operation that could interrupt power.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eCommissioning sequence\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eInstall the module according to the applicable Yokogawa hardware manual.\u003c\/li\u003e\n\u003cli\u003eVerify seating, mechanical retention, and connector engagement.\u003c\/li\u003e\n\u003cli\u003eCheck the battery switch position and confirm backup availability.\u003c\/li\u003e\n\u003cli\u003eInspect Ethernet, USB, and RS-232 connections used by the application.\u003c\/li\u003e\n\u003cli\u003eStart the processor using the approved system procedure.\u003c\/li\u003e\n\u003cli\u003eReview STATUS LED indications and confirm the expected domain and station settings.\u003c\/li\u003e\n\u003cli\u003eVerify controller communication and system operation before returning the process to service.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance recommendations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInspect front-panel switches during planned maintenance.\u003c\/li\u003e\n\u003cli\u003eReview battery backup condition and follow the manufacturer's replacement procedure.\u003c\/li\u003e\n\u003cli\u003eCheck connectors for looseness, contamination, or mechanical damage.\u003c\/li\u003e\n\u003cli\u003eInvestigate unexpected processor stops before attempting repeated restarts.\u003c\/li\u003e\n\u003cli\u003eRecord switch changes and processor replacement details in the maintenance log.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Certifications and Compliance Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe supplied product information lists the following certifications and compliance references:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eSIL 3 according to IEC 61508\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCertification verification:\u003c\/strong\u003e The model suffix description identifies the SCP451-51 as a standard type with no explosion protection. Therefore, do not assume that the listed ATEX or IECEx references authorize this exact suffix for hazardous-area installation. Confirm the product-specific certificate, marking, and system approval before specifying it for a safety or hazardous-area application.\u003c\/p\u003e\n\u003cp\u003eLikewise, a SIL 3 reference does not establish that an individual processor module independently provides a SIL 3 safety function. Verify the approved system architecture, safety manual, and certification scope.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Engineering Selection Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUse the following checks when selecting the SCP451-51 for a replacement or system expansion project.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSelection Item\u003c\/th\u003e\n\u003cth\u003eWhat to Verify\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel identification\u003c\/td\u003e\n\u003ctd\u003eConfirm SCP451-51 and the complete product code.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem compatibility\u003c\/td\u003e\n\u003ctd\u003eCheck the target controller platform, hardware revision, and system software requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental option\u003c\/td\u003e\n\u003ctd\u003eConfirm the ISA Standard G3 requirement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion protection\u003c\/td\u003e\n\u003ctd\u003eNote that the stated suffix is a standard type without explosion protection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery backup\u003c\/td\u003e\n\u003ctd\u003eCheck battery condition and management-data retention requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eConfirm Ethernet and serial interface requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog outputs\u003c\/td\u003e\n\u003ctd\u003eVerify whether the supplied four-channel output data belongs to this processor or a separate I\/O module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety application\u003c\/td\u003e\n\u003ctd\u003eReview the exact certification scope and approved system configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":68128904970422,"sku":"SCP451-51","price":113.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/SCP451-51-1.jpg?v=1795420358","url":"https:\/\/www.plcsparehub.com\/products\/scp451-51-yokogawa-industrial-processor-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}