{"product_id":"schneider-electric-stbdao5260-advantys-stb-115v-ac-output-module","title":"Schneider Electric STBDAO5260 Advantys STB 115V AC Output Module","description":" \u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1673c5;\"\u003eSchneider Electric STBDAO5260\u003c\/span\u003e\u003c\/strong\u003e belongs to the \u003cstrong\u003eAdvantys STB distributed I\/O platform\u003c\/strong\u003e. This standard digital output module provides two isolated 115V AC output channels.\u003c\/p\u003e\n\n\u003cp\u003eEach channel supports an output current of up to \u003cstrong\u003e2 A\u003c\/strong\u003e. The module provides \u003cstrong\u003e1780V AC field-to-bus isolation\u003c\/strong\u003e for electrical separation between field circuits and the internal bus.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eSTBDAO5260\u003c\/strong\u003e supports hot swapping within its compatible Advantys STB configuration. It connects to the system through the \u003cstrong\u003eSTBXBA2000 I\/O base\u003c\/strong\u003e and requires the \u003cstrong\u003eSTBPDT2100 power distribution module (PDM)\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eEngineers can use this module to control AC-operated field devices. Typical loads include compatible contactors, relays, and industrial actuators.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSTBDAO5260\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eAdvantys STB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eStandard isolated digital output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e115V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e2 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField-to-Bus Isolation\u003c\/td\u003e\n\u003ctd\u003e1780V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swapping\u003c\/td\u003e\n\u003ctd\u003eSupported within compatible system configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Distribution\u003c\/td\u003e\n\u003ctd\u003e115V AC supplied through the PDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible I\/O Base\u003c\/td\u003e\n\u003ctd\u003eSTBXBA2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Base Width\u003c\/td\u003e\n\u003ctd\u003e18.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible PDM\u003c\/td\u003e\n\u003ctd\u003eSTBPDT2100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePDM Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e115\/230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFunctional Characteristics and Engineering Details\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput architecture:\u003c\/strong\u003e Two independent AC digital output channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad capability:\u003c\/strong\u003e Each channel supports up to 2 A, subject to load and system operating limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical isolation:\u003c\/strong\u003e 1780V AC field-to-bus isolation helps separate field wiring from internal bus circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem integration:\u003c\/strong\u003e The STBXBA2000 base provides the module mounting interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower distribution:\u003c\/strong\u003e The STBPDT2100 distributes the required AC field supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Hot-swapping support can reduce replacement downtime under approved system procedures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eMeasurement and signal characteristics:\u003c\/strong\u003e This is a switching output module, not an analog measurement device. Measurement range, sensitivity, linearity, and resolution therefore do not apply. The supplied specifications do not state frequency response or switching frequency.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003col\u003e\n\u003cli\u003eVerify the module model and the Advantys STB system configuration.\u003c\/li\u003e\n\u003cli\u003eConfirm the availability of the compatible \u003cstrong\u003eSTBXBA2000 I\/O base\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eInstall the \u003cstrong\u003eSTBPDT2100 PDM\u003c\/strong\u003e according to the system power distribution design.\u003c\/li\u003e\n\u003cli\u003eCheck the AC supply voltage and field wiring requirements.\u003c\/li\u003e\n\u003cli\u003eMount the module securely and verify its mechanical connection.\u003c\/li\u003e\n\u003cli\u003eConnect each output channel to its designated field load.\u003c\/li\u003e\n\u003cli\u003eCheck terminal assignments against the official Schneider Electric wiring documentation.\u003c\/li\u003e\n\u003cli\u003eInspect wiring polarity, protective devices, and grounding arrangements.\u003c\/li\u003e\n\u003cli\u003eRestore power and verify the module's communication and output status.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cp\u003e\u003cstrong\u003eSafety note:\u003c\/strong\u003e Isolate field power before performing wiring or maintenance. Never assume hot swapping permits live field wiring work.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eCommissioning should begin with a verification of the power distribution arrangement. Confirm the PDM supply voltage before enabling field outputs.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel testing:\u003c\/strong\u003e Activate each output separately and verify the corresponding field device response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad verification:\u003c\/strong\u003e Measure the actual load current under normal operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage inspection:\u003c\/strong\u003e Check the 115V AC supply at the field circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring inspection:\u003c\/strong\u003e Look for loose terminals, damaged insulation, and overheated connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem diagnostics:\u003c\/strong\u003e Compare commanded output states with actual field device behavior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement:\u003c\/strong\u003e Follow Schneider Electric hot-swapping procedures and system interlock requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFor example, a contactor may fail to energize despite a valid PLC output command. Engineers should check the PDM supply, channel wiring, load condition, and contactor coil before replacing the module.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial motor control:\u003c\/strong\u003e Switching compatible AC contactor coils.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess automation:\u003c\/strong\u003e Operating AC control devices in distributed I\/O cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine control:\u003c\/strong\u003e Controlling compatible AC actuators and auxiliary equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturing systems:\u003c\/strong\u003e Switching field loads in automated production lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtility installations:\u003c\/strong\u003e Operating compatible AC interface devices in industrial control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCompatibility and Configuration Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eSTBDAO5260\u003c\/strong\u003e belongs to the Schneider Electric Advantys STB platform. Correct installation requires attention to the base, power distribution, and network configuration.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePurpose\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSTBDAO5260\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-channel 115V AC digital output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Base\u003c\/td\u003e\n\u003ctd\u003eSTBXBA2000\u003c\/td\u003e\n\u003ctd\u003eModule mounting and electrical interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Distribution Module\u003c\/td\u003e\n\u003ctd\u003eSTBPDT2100\u003c\/td\u003e\n\u003ctd\u003e115\/230V AC power distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eBefore ordering, verify the complete island configuration and the applicable hardware revision. Confirm the field supply voltage, load current, and terminal arrangement.\u003c\/p\u003e\n\n\u003cp\u003eDo not assume compatibility with other Advantys modules solely from their shared product family. Check the island design documentation and system configuration rules.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities and Field Troubleshooting\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eSTBDAO5260\u003c\/strong\u003e serves as an AC switching device within the distributed I\/O architecture. Engineers can diagnose related field problems through systematic electrical checks.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput not responding:\u003c\/strong\u003e Check the controller command, communication status, and module configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad does not energize:\u003c\/strong\u003e Measure the AC supply and inspect the output wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntermittent operation:\u003c\/strong\u003e Check terminal tightness and unstable field supply conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnexpected output behavior:\u003c\/strong\u003e Inspect the control logic and field load characteristics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule replacement:\u003c\/strong\u003e Verify base compatibility and PDM configuration before installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003ePractical example:\u003c\/strong\u003e A 115V AC relay may fail to operate during machine startup. First, verify the PDM output voltage and field wiring. Then check the relay coil current against the channel's 2 A rating. This approach helps distinguish wiring faults from load-related problems.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Electrical Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Consideration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60°C ambient operating range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n\u003ctd\u003eIP20; install inside a suitable electrical enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003e1780V AC field-to-bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference Resistance\u003c\/td\u003e\n\u003ctd\u003eNot specified in the supplied data; follow the system EMC installation requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003eNot specified; this is a digital switching output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCertifications and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eSpecific certification numbers and approval markings have not been provided for this product. Please consult the applicable Schneider Electric product documentation for verified regulatory and regional compliance information.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eFrom an industrial maintenance perspective, the \u003cstrong\u003eSTBDAO5260\u003c\/strong\u003e requires careful coordination between field power distribution and output load selection.\u003c\/p\u003e\n\n\u003cp\u003eIts two-channel architecture supports compact AC switching applications. However, engineers should evaluate each load independently before connecting field devices.\u003c\/p\u003e\n\n\u003cp\u003eFor example, two contactor coils may share one module while operating separate machine functions. Each channel must remain within its 2 A output rating. The PDM must also support the actual field supply requirements.\u003c\/p\u003e\n\n\u003cp\u003eDuring troubleshooting, engineers should separate controller commands from electrical output conditions. A correct PLC command does not guarantee sufficient field voltage. Checking the PDM, wiring, and load first can prevent unnecessary module replacement.\u003c\/p\u003e\n\n\u003cp\u003eFor replacement projects, verify the \u003cstrong\u003eSTBDAO5260\u003c\/strong\u003e model, \u003cstrong\u003eSTBXBA2000\u003c\/strong\u003e base, and \u003cstrong\u003eSTBPDT2100\u003c\/strong\u003e PDM together. This verification reduces configuration errors during maintenance.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: What is the main function of the Schneider Electric STBDAO5260?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe STBDAO5260 provides two isolated 115V AC digital output channels. Each channel supports up to 2 A.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Which I\/O base does the STBDAO5260 require?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eIt uses the STBXBA2000 I\/O base. Confirm the complete island configuration before installation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Which power distribution module should I select?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe specified PDM is the STBPDT2100. It supports the 115\/230V AC power distribution arrangement.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: Can the STBDAO5260 control two contactors simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes, provided each channel drives a compatible load within its 2 A rating. Check coil inrush current and switching requirements before commissioning.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: What should engineers check when an output channel fails?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eStart with the controller command and module configuration. Then inspect PDM voltage, field wiring, terminal connections, and load current.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ6: Does hot swapping eliminate the need to isolate field power?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eNo. Hot-swapping support does not remove electrical safety requirements. Follow the manufacturer's replacement procedure and isolate field circuits when required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ7: What should buyers verify before ordering an STBDAO5260?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eConfirm the exact model, two-channel 115V AC output requirement, 2 A channel rating, I\/O base, and PDM. Also verify system compatibility and the required product revision.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ8: How can I select a replacement for an existing module?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eCompare the electrical specifications and system configuration. Do not select a replacement based only on the Advantys STB series name.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePackaging and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e1 × Schneider Electric \u003cstrong\u003eSTBDAO5260\u003c\/strong\u003e digital output module.\u003c\/li\u003e\n\u003cli\u003eStandard protective packaging for transportation.\u003c\/li\u003e\n\u003cli\u003e12-month warranty.\u003c\/li\u003e\n\u003cli\u003eTechnical assistance for model verification and compatibility checks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eAccessories, I\/O bases, and power distribution modules are not included unless specified in the quotation.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eOrdering and Shipping Information\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Schneider Electric STBDAO5260.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Advantys STB.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch:\u003c\/strong\u003e Typically within 24–48 hours after order confirmation and stock verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e FedEx, UPS, and DHL international delivery options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInquiry:\u003c\/strong\u003e Contact our sales team for current availability, pricing, and shipping arrangements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eContact \u003cstrong\u003eGlobal PLC Spare HUB\u003c\/strong\u003e for product quotations and technical assistance. Provide your model number and system requirements for accurate order verification.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":67982038401206,"sku":"STBDAO5260","price":109.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/STBDAO5260-1.jpg?v=1793678070","url":"https:\/\/www.plcsparehub.com\/products\/schneider-electric-stbdao5260-advantys-stb-115v-ac-output-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}