{"product_id":"schneider-electric-140dio33000-quantum-discrete-output-module","title":"Schneider Electric 140DIO33000 Quantum Discrete Output Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eSchneider Electric\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003eModicon Quantum\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003e140DIO33000\u003c\/strong\u003e discrete output module delivers reliable intrinsically safe digital switching.\u003c\/p\u003e\n\u003cp\u003eEngineers design this module specifically for explosive gas and dust environments across modern process industries.\u003c\/p\u003e\n\u003cp\u003eIt interfaces low-power control electronics with field devices located in Zone 20, 21, and 22 hazardous areas.\u003c\/p\u003e\n\u003cp\u003eThe unit features eight open collector outputs with precise 24 V DC voltage regulation.\u003c\/p\u003e\n\u003cp\u003eSolid-state switching eliminates mechanical contact wear and extends overall operational life.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eSpecification Parameter\u003c\/th\u003e\n\u003cth\u003eTechnical Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdentity \u0026amp; Hardware Architecture\u003c\/td\u003e\n\u003ctd\u003eBrand \u0026amp; Series\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003eSchneider Electric\u003c\/strong\u003e \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/modicon-quantum-series\"\u003e\u003cstrong style=\"color: #0056b3;\"\u003eModicon Quantum\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdentity \u0026amp; Hardware Architecture\u003c\/td\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #0056b3;\"\u003e140DIO33000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdentity \u0026amp; Hardware Architecture\u003c\/td\u003e\n\u003ctd\u003eModule Format \u0026amp; Weight\u003c\/td\u003e\n\u003ctd\u003eStandard Quantum Slot \/ 0.99 lb (0.45 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Output Characteristics\u003c\/td\u003e\n\u003ctd\u003eDiscrete Output Voltage \u0026amp; Type\u003c\/td\u003e\n\u003ctd\u003e24 V DC \/ Open Collector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Output Characteristics\u003c\/td\u003e\n\u003ctd\u003eChannel Resolution \u0026amp; Density\u003c\/td\u003e\n\u003ctd\u003e8 Intrinsically Safe Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Output Characteristics\u003c\/td\u003e\n\u003ctd\u003eCurrent Capacity per Point \/ Module\u003c\/td\u003e\n\u003ctd\u003e45 mA per point \/ 360 mA total module load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Output Characteristics\u003c\/td\u003e\n\u003ctd\u003eOff-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e0.4 mA maximum per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Output Characteristics\u003c\/td\u003e\n\u003ctd\u003eBackplane Bus Current \u0026amp; Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e2.2 A bus requirement \/ 5 W dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Dynamics \u0026amp; Isolation\u003c\/td\u003e\n\u003ctd\u003eResponse Time (State 0 to 1 \/ 1 to 0)\u003c\/td\u003e\n\u003ctd\u003e1 ms resistive (turn-on) \/ 1 ms resistive (turn-off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Dynamics \u0026amp; Isolation\u003c\/td\u003e\n\u003ctd\u003eDielectric Isolation Rating\u003c\/td\u003e\n\u003ctd\u003e2500 V DC for 1 minute \/ 1780 V AC at 47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental \u0026amp; Noise Immunity\u003c\/td\u003e\n\u003ctd\u003eOperating \u0026amp; Storage Temperature\u003c\/td\u003e\n\u003ctd\u003e32°F to 140°F (0°C to 60°C) \/ -40°F to 185°F (-40°C to 85°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental \u0026amp; Noise Immunity\u003c\/td\u003e\n\u003ctd\u003eRelative Humidity \u0026amp; Altitude Limit\u003c\/td\u003e\n\u003ctd\u003e95% non-condensing \/ Up to 16,404 ft (5000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental \u0026amp; Noise Immunity\u003c\/td\u003e\n\u003ctd\u003eElectrostatic Discharge (ESD) Immunity\u003c\/td\u003e\n\u003ctd\u003e4 kV contact \/ 8 kV air (IEC 801-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental \u0026amp; Noise Immunity\u003c\/td\u003e\n\u003ctd\u003eElectromagnetic Field Resistance\u003c\/td\u003e\n\u003ctd\u003e9.1 V\/m (10 V\/m) at 80 to 2000 MHz (IEC 801-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurn off backplane power prior to inserting the module into the Quantum rack.\u003c\/li\u003e\n\u003cli\u003eVerify intrinsic safety barrier wiring protocols according to EN 50020 standard guidelines.\u003c\/li\u003e\n\u003cli\u003eRoute intrinsically safe field cables separately from standard power lines to prevent coupling.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the module chassis to maintain full ESD shielding performance.\u003c\/li\u003e\n\u003cli\u003eDo not perform hot swapping during operation per intrinsic safety compliance mandates.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInspect internal fuse integrity prior to powering up the automation rack system.\u003c\/li\u003e\n\u003cli\u003eUse calibration meters to verify 24 V DC voltage output across active field circuits.\u003c\/li\u003e\n\u003cli\u003eCheck off-state leakage current to ensure values remain below 0.4 mA per point.\u003c\/li\u003e\n\u003cli\u003ePerform routine visual checks on terminal block wire contacts and chassis latch points.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with \u003cstrong style=\"color: #0056b3;\"\u003eSchneider Electric\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003eModicon Quantum\u003c\/strong\u003e automation backplanes.\u003c\/li\u003e\n\u003cli\u003eSupported in Concept V2.2 and above programming software packages.\u003c\/li\u003e\n\u003cli\u003eFully functional with ProWORX 32 programming and configuration utilities.\u003c\/li\u003e\n\u003cli\u003eSeamlessly integrates into EcoStruxure Control Expert (Unity Pro) software environments.\u003c\/li\u003e\n\u003cli\u003eOperates alongside field devices rated for Zone 20, 21, or 22 hazardous areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications \u0026amp; Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification Body \/ Directive\u003c\/th\u003e\n\u003cth\u003eCompliance Standard Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Directive\u003c\/td\u003e\n\u003ctd\u003eDirective 94\/9\/EC \/ SIRA 02ATEX2345X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Marking\u003c\/td\u003e\n\u003ctd\u003eCE II1 G\/D-EEx ia IIC \/ FM Class 1 Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Electrical Standards\u003c\/td\u003e\n\u003ctd\u003eEN 50014, EN 50020, EN 50039, EN 50028, EN 50281-1-1, EN 50284\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNorth American Safety Standards\u003c\/td\u003e\n\u003ctd\u003eUL 508 \/ CSA C22.2 No 142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternational Certifications\u003c\/td\u003e\n\u003ctd\u003eC-tick \/ GOST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eControlling solenoid valves in chemical processing plants located inside hazardous areas.\u003c\/li\u003e\n\u003cli\u003eOperating alarm annunciators in oil and gas offshore processing platforms.\u003c\/li\u003e\n\u003cli\u003eActuating discrete relay coils in pharmaceutical powder handling environments.\u003c\/li\u003e\n\u003cli\u003eManaging field indicator lamps in grain handling storage facilities with explosive dust.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTransient voltage suppression circuits guard output channels against severe inductive spikes.\u003c\/li\u003e\n\u003cli\u003eInternal fuses protect internal backplane connections from external overcurrent faults.\u003c\/li\u003e\n\u003cli\u003eReal-time LED indicators report logic-side power states and individual channel signal activity.\u003c\/li\u003e\n\u003cli\u003eSoftware diagnostic flags detect open-circuit line faults and supply power drops instantly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents \u0026amp; Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem Parameter\u003c\/th\u003e\n\u003cth\u003eDetail Information\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimensions\u003c\/td\u003e\n\u003ctd\u003e12.40 in x 6.50 in x 1.97 in (31.5 cm x 16.5 cm x 5.0 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Gross Weight\u003c\/td\u003e\n\u003ctd\u003e1.545 lb (0.701 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty Term\u003c\/td\u003e\n\u003ctd\u003e12 Months Comprehensive Coverage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDispatch Speed\u003c\/td\u003e\n\u003ctd\u003eShipped within 24 to 48 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Express Carriers\u003c\/td\u003e\n\u003ctd\u003eFedEx, UPS, DHL express delivery options available worldwide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOur automation engineers often encounter field issues caused by improper cable separation in intrinsically safe installations.\u003c\/p\u003e\n\u003cp\u003eDuring a chemical plant upgrade, field technicians experienced ghost triggering on output channels.\u003c\/p\u003e\n\u003cp\u003eThe team traced the interference to adjacent 230 V AC motor lines running inside the same conduit.\u003c\/p\u003e\n\u003cp\u003eInstalling the \u003cstrong style=\"color: #0056b3;\"\u003eModicon Quantum\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003e140DIO33000\u003c\/strong\u003e with dedicated shielded wiring resolved all electrical noise problems immediately.\u003c\/p\u003e\n\u003cp\u003eIts robust 2500 V DC isolation and 10 V\/m noise resistance ensured completely stable output switching.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: Can I hot swap the \u003cstrong style=\"color: #0056b3;\"\u003e140DIO33000\u003c\/strong\u003e module while the rack is energized?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: No, standard safety regulations prohibit hot swapping intrinsically safe modules to prevent electrical sparking risks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What cable distance is recommended for 24 V DC open collector outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Field experience indicates keeping cable lengths under 300 meters minimizes line resistance and signal degradation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: How do I select between the \u003cstrong style=\"color: #0056b3;\"\u003e140DIO33000\u003c\/strong\u003e and standard discrete output modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Choose the \u003cstrong style=\"color: #0056b3;\"\u003e140DIO33000\u003c\/strong\u003e whenever field actuators sit in hazardous Zone 20, 21, or 22 environments requiring ATEX certification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What programming software supports configuration of this output card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: You can configure this card using Unity Pro, Concept V2.2 or higher, and ProWORX software platforms.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45013803958454,"sku":"140DIO33000","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/140DIO33000_fac2971d-362d-407a-a256-30dfe365e72d.jpg?v=1786946694","url":"https:\/\/www.plcsparehub.com\/products\/schneider-electric-140dio33000-quantum-discrete-output-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}