{"product_id":"rockwell-allen-bradley-1747-cp3-slc-500-rs232-programming-cable","title":"Rockwell Allen-Bradley 1747-CP3 SLC 500 RS232 Programming Cable","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eAllen-Bradley 1747-CP3\u003c\/span\u003e SLC 500 Programmer Cable Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eAllen-Bradley 1747-CP3\u003c\/span\u003e\u003c\/strong\u003e is a professional RS232 programmer cable for the \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eSLC 500\u003c\/span\u003e\u003c\/strong\u003e automation platform.\u003c\/p\u003e\n\n\u003cp\u003eThis cable enables stable communication between industrial controllers and engineering workstations.\u003c\/p\u003e\n\n\u003cp\u003eThe cable supports programming, diagnostics, firmware communication, and controller configuration tasks.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003e1747-CP3\u003c\/span\u003e\u003c\/strong\u003e features a null modem communication structure for reliable serial data transfer.\u003c\/p\u003e\n\n\u003cp\u003eThe assembly uses industrial-grade shielding for enhanced anti-interference performance.\u003c\/p\u003e\n\n\u003cp\u003eIt supports industrial automation environments with demanding electrical conditions.\u003c\/p\u003e\n\n\u003cp\u003eThe cable connects directly to compatible SLC processors and PanelView terminals.\u003c\/p\u003e\n\n\u003cp\u003eIts compact structure simplifies cabinet routing and onsite maintenance operations.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eAllen-Bradley 1747-CP3\u003c\/span\u003e\u003c\/strong\u003e remains widely used in legacy and active industrial control systems.\u003c\/p\u003e\n\n\u003cp\u003eEngineers value this cable for dependable RS232 communication stability.\u003c\/p\u003e\n\n\u003cp\u003eThe cable performs well in industrial environments with electrical noise.\u003c\/p\u003e\n\n\u003cp\u003eIts Belden cable structure improves long-distance communication reliability.\u003c\/p\u003e\n\n\u003cp\u003eThe null modem configuration reduces communication mismatch issues during commissioning.\u003c\/p\u003e\n\n\u003cp\u003eThis model suits maintenance teams supporting mature \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eSLC 500\u003c\/span\u003e\u003c\/strong\u003e installations.\u003c\/p\u003e\n\n\u003cp\u003eIt also supports rapid troubleshooting during controller replacement or software updates.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eAllen-Bradley\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Rockwell Automation\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003e1747-CP3\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eSLC 500\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e RS232 Programmer Cable\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eCable Structure:\u003c\/strong\u003e 9-Pin D Shell Null Modem Cable\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 118 inches (3 meters)\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eCable Material:\u003c\/strong\u003e Belden 9463\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eConnector Type:\u003c\/strong\u003e 6-Pin Phoenix Connector\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eCommunication Interface:\u003c\/strong\u003e RS232 Serial Communication\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eSupported Processors:\u003c\/strong\u003e SLC 5\/02, 5\/03, 5\/04, and 5\/05\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eCompatible Devices:\u003c\/strong\u003e PanelView terminals and MicroLogix controllers\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e 800 mA at 5V DC\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eStorage Environment:\u003c\/strong\u003e Dry industrial indoor installation\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eEMC Resistance:\u003c\/strong\u003e Industrial-grade electromagnetic immunity\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eAnti-Interference Capability:\u003c\/strong\u003e Shielded cable structure minimizes signal noise\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eSignal Stability:\u003c\/strong\u003e Stable serial communication over industrial distances\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e Suitable for industrial electrical environments\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 5.72 x 1.37 x 5.15 inches\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.37 pounds (168 grams)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eKey Functional Features\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eSupports PLC programming and online diagnostics.\u003c\/li\u003e\n\n\u003cli\u003eEnables stable controller-to-PC communication.\u003c\/li\u003e\n\n\u003cli\u003eSupports firmware transfer and configuration tasks.\u003c\/li\u003e\n\n\u003cli\u003eReduces communication interruption risks.\u003c\/li\u003e\n\n\u003cli\u003eSupports industrial commissioning applications.\u003c\/li\u003e\n\n\u003cli\u003eProvides reliable serial data transmission.\u003c\/li\u003e\n\n\u003cli\u003eImproves maintenance efficiency during troubleshooting.\u003c\/li\u003e\n\n\u003cli\u003eSimplifies engineering workstation connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCompatibility Information\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eCompatible with \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eAllen-Bradley SLC 500\u003c\/span\u003e\u003c\/strong\u003e controllers.\u003c\/li\u003e\n\n\u003cli\u003eSupports SLC 5\/02 controller communication.\u003c\/li\u003e\n\n\u003cli\u003eSupports SLC 5\/03 controller programming.\u003c\/li\u003e\n\n\u003cli\u003eSupports SLC 5\/04 controller diagnostics.\u003c\/li\u003e\n\n\u003cli\u003eSupports SLC 5\/05 controller connectivity.\u003c\/li\u003e\n\n\u003cli\u003eCompatible with selected PanelView operator terminals.\u003c\/li\u003e\n\n\u003cli\u003eSupports MicroLogix serial communication applications.\u003c\/li\u003e\n\n\u003cli\u003eWorks with industrial engineering workstations using RS232 ports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003ePLC software uploading and downloading.\u003c\/li\u003e\n\n\u003cli\u003eIndustrial machine commissioning projects.\u003c\/li\u003e\n\n\u003cli\u003eFactory automation troubleshooting tasks.\u003c\/li\u003e\n\n\u003cli\u003eControl cabinet maintenance operations.\u003c\/li\u003e\n\n\u003cli\u003eProduction line controller diagnostics.\u003c\/li\u003e\n\n\u003cli\u003ePanelView communication integration.\u003c\/li\u003e\n\n\u003cli\u003eIndustrial retrofit engineering projects.\u003c\/li\u003e\n\n\u003cli\u003eLegacy automation system support.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic and Maintenance Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eSupports real-time PLC communication testing.\u003c\/li\u003e\n\n\u003cli\u003eHelps identify serial communication faults.\u003c\/li\u003e\n\n\u003cli\u003eImproves troubleshooting speed during downtime.\u003c\/li\u003e\n\n\u003cli\u003eSupports maintenance software connectivity.\u003c\/li\u003e\n\n\u003cli\u003eAllows rapid controller parameter verification.\u003c\/li\u003e\n\n\u003cli\u003eReduces commissioning delays during startup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eVerify controller compatibility before installation.\u003c\/li\u003e\n\n\u003cli\u003eConnect the cable securely before powering communication devices.\u003c\/li\u003e\n\n\u003cli\u003eAvoid excessive cable bending during installation.\u003c\/li\u003e\n\n\u003cli\u003eKeep cable routing away from high-voltage wiring.\u003c\/li\u003e\n\n\u003cli\u003eUse grounded industrial equipment for stable communication.\u003c\/li\u003e\n\n\u003cli\u003eInspect connectors before commissioning operations.\u003c\/li\u003e\n\n\u003cli\u003eDo not disconnect the cable during active data transfer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance Convenience\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eCompact design simplifies field installation.\u003c\/li\u003e\n\n\u003cli\u003ePlug-and-connect structure improves engineering efficiency.\u003c\/li\u003e\n\n\u003cli\u003eIndustrial shielding improves communication reliability.\u003c\/li\u003e\n\n\u003cli\u003eDurable construction supports repeated maintenance tasks.\u003c\/li\u003e\n\n\u003cli\u003eEasy replacement reduces system downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCertification and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eComplies with Council Directive 89\/336\/EEC EMC requirements.\u003c\/li\u003e\n\n\u003cli\u003eComplies with Council Directive 73\/23\/EEC Low Voltage requirements.\u003c\/li\u003e\n\n\u003cli\u003ePassed EN 50081-2 EMC emission standards.\u003c\/li\u003e\n\n\u003cli\u003ePassed EN 50082-2 EMC immunity standards.\u003c\/li\u003e\n\n\u003cli\u003eDesigned for industrial automation environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePackaging Information\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eAllen-Bradley 1747-CP3\u003c\/span\u003e\u003c\/strong\u003e Programmer Cable\u003c\/li\u003e\n\n\u003cli\u003eProtective industrial packaging\u003c\/li\u003e\n\n\u003cli\u003eProduct identification labeling\u003c\/li\u003e\n\n\u003cli\u003eQuality inspection before shipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eShipping and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eFast shipping within 24-48 hours.\u003c\/li\u003e\n\n\u003cli\u003eWorldwide delivery available.\u003c\/li\u003e\n\n\u003cli\u003eShipping carriers include FedEx, UPS, and DHL.\u003c\/li\u003e\n\n\u003cli\u003eProfessional export packaging protects the product during transportation.\u003c\/li\u003e\n\n\u003cli\u003e12-month warranty coverage included.\u003c\/li\u003e\n\n\u003cli\u003eTechnical support available for installation assistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the main function of \u003cspan style=\"color:#c00000;\"\u003e1747-CP3\u003c\/span\u003e?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe cable enables RS232 communication between PLC systems and engineering computers.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhich controllers support this cable?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eIt supports SLC 5\/02, 5\/03, 5\/04, and 5\/05 processors.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan this cable support PanelView terminals?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes. It supports selected PanelView communication applications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes the cable support industrial environments?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes. The cable includes industrial EMC protection and shielding.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat communication issues appear during commissioning?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eLoose serial connectors often cause unstable communication.\u003c\/p\u003e\n\n\u003cp\u003eIncorrect COM port settings may also interrupt communication.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow can engineers improve communication stability?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eKeep the cable away from inverter power wiring.\u003c\/p\u003e\n\n\u003cp\u003eUse grounded industrial computers whenever possible.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat should users check before purchasing?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eVerify controller model compatibility and communication interface requirements.\u003c\/p\u003e\n\n\u003cp\u003eConfirm the engineering workstation supports RS232 communication.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy do maintenance teams prefer Belden cable structures?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eBelden cable materials improve shielding and signal integrity.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs this cable suitable for long-term maintenance inventory?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes. Many industrial facilities maintain spare communication cables onsite.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eRecommended Equipment Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eIndustrial PLC control cabinets\u003c\/li\u003e\n\n\u003cli\u003ePackaging machinery systems\u003c\/li\u003e\n\n\u003cli\u003eProcess automation equipment\u003c\/li\u003e\n\n\u003cli\u003eFactory production lines\u003c\/li\u003e\n\n\u003cli\u003eWater treatment control systems\u003c\/li\u003e\n\n\u003cli\u003ePower generation auxiliary systems\u003c\/li\u003e\n\n\u003cli\u003eMaterial handling automation equipment\u003c\/li\u003e\n\n\u003cli\u003eIndustrial HMI communication systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45014041559222,"sku":"1747-CP3","price":161.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/1747-CP3_2abaac84-77d5-4115-b0c8-e6508f5ba4b2.jpg?v=1779790722","url":"https:\/\/www.plcsparehub.com\/products\/rockwell-allen-bradley-1747-cp3-slc-500-rs232-programming-cable","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}