{"product_id":"rgs40-s-renishaw-40µm-gold-steel-encoder-tape","title":"RGS40-S Renishaw 40µm Gold Steel Encoder Tape","description":"\u003ch3\u003e\u003cstrong\u003eRenishaw RGS40-S | RG4 Series 40 µm Precision Linear Encoder Scale\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eRenishaw RGS40-S\u003c\/span\u003e\u003c\/strong\u003e is a reflective, gold-plated steel tape scale designed for high-accuracy incremental linear measurement. It belongs to the \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eRGS40 scale family\u003c\/span\u003e\u003c\/strong\u003e and provides a 40 µm graduation pitch.\u003c\/p\u003e\n\u003cp\u003eIts thin steel construction follows the thermal expansion behavior of the mounting substrate. This characteristic helps maintain measurement stability across changing machine temperatures.\u003c\/p\u003e\n\u003cp\u003eThe integrated adhesive backing supports direct installation on prepared metal, granite, ceramic, and composite surfaces. Epoxy-mounted end clamps secure the scale without requiring substrate drilling.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRGS40-S\u003c\/strong\u003e works with compatible \u003cstrong\u003eRenishaw RGH34 and RGH41 readheads\u003c\/strong\u003e. It suits precision machine tools, semiconductor positioning stages, coordinate measurement equipment, and automated inspection systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Product Identity and Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRenishaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRGS40-S\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eRGS40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEncoder System\u003c\/td\u003e\n\u003ctd\u003eRG4 Series Compatible Linear Encoder System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eReflective Gold-Plated Steel Tape Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eIncremental Optical Linear Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Pitch\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e40 µm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Material\u003c\/td\u003e\n\u003ctd\u003eFlexible steel tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurface Finish\u003c\/td\u003e\n\u003ctd\u003eGold-plated reflective surface with protective lacquer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacking\u003c\/td\u003e\n\u003ctd\u003eSpecially formulated self-adhesive backing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThickness\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.2 mm, including adhesive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e±3 µm\/m; ±1 µm over 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Supply Length\u003c\/td\u003e\n\u003ctd\u003e100 mm to 50 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended Length\u003c\/td\u003e\n\u003ctd\u003eAbove 50 m by special order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 °C to +120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Installation Temperature\u003c\/td\u003e\n\u003ctd\u003e+10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Readheads\u003c\/td\u003e\n\u003ctd\u003eRGH34 and RGH41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Configuration Breakdown and Construction\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eRGS40-S\u003c\/strong\u003e designation identifies a specific 40 µm steel tape scale configuration. It does not use the same suffix structure as electronic readhead models.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRGS40\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRGS: Renishaw reflective steel tape scale family.\u003c\/li\u003e\n\u003cli\u003e40: 40 µm incremental scale pitch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eProtective lacquer surface finish.\u003c\/li\u003e\n\u003cli\u003eGold-plated reflective steel construction.\u003c\/li\u003e\n\u003cli\u003eSelf-adhesive mounting backing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction Layers:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLayer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReflective Surface\u003c\/td\u003e\n\u003ctd\u003eProvides the optical surface for readhead scanning.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Lacquer\u003c\/td\u003e\n\u003ctd\u003eProtects the reflective surface during normal operation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteel Substrate\u003c\/td\u003e\n\u003ctd\u003eProvides a thin, flexible dimensional reference.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdhesive Backing\u003c\/td\u003e\n\u003ctd\u003eSecures the scale to the prepared machine surface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Thermal Behavior and Measurement Accuracy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe RGS40-S uses a thin-section steel construction. Its thermal behavior follows the mounting substrate after proper installation and end fixing.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e ±3 µm\/m under specified measurement conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal Linearity:\u003c\/strong\u003e ±1 µm over a 60 mm measuring length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Matching:\u003c\/strong\u003e The installed scale follows the substrate expansion coefficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubstrate Compatibility:\u003c\/strong\u003e Suitable materials have expansion coefficients between 0 and 22 µm\/m\/°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Fixing:\u003c\/strong\u003e Epoxy-mounted clamps prevent uncontrolled scale-end movement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Stability:\u003c\/strong\u003e End movement remains below 1 µm over -20 °C to +50 °C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis thermal arrangement reduces differential movement between the scale and machine structure. It supports repeatable measurements during normal machine temperature changes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Consideration:\u003c\/strong\u003e Scale linearity describes the scale itself. Complete machine accuracy also depends on readhead performance, mounting geometry, controller interpolation, and mechanical positioning errors.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Installation Architecture and Mounting Accessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe adhesive-backed design eliminates the need for mounting holes along the scale path. The installation surface must provide adequate flatness, cleanliness, and adhesion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended Installation Sequence:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eInspect the mounting surface for scratches, burrs, and contamination.\u003c\/li\u003e\n\u003cli\u003eConfirm the substrate expansion coefficient falls within the specified range.\u003c\/li\u003e\n\u003cli\u003eClean and prepare the mounting surface according to Renishaw instructions.\u003c\/li\u003e\n\u003cli\u003eAllow the scale and substrate to reach the installation temperature.\u003c\/li\u003e\n\u003cli\u003eAlign the tape with the machine's intended measurement axis.\u003c\/li\u003e\n\u003cli\u003eApply the adhesive-backed scale without trapping air or creating wrinkles.\u003c\/li\u003e\n\u003cli\u003eSecure both scale ends with epoxy-mounted end clamps.\u003c\/li\u003e\n\u003cli\u003eInstall the compatible readhead and verify its alignment.\u003c\/li\u003e\n\u003cli\u003eCheck incremental signals and reference positioning during commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eEnd-Fixing Components:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9523-4015\u003c\/td\u003e\n\u003ctd\u003eEpoxy-mounted scale end clamps.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9531-0342\u003c\/td\u003e\n\u003ctd\u003eTwo-part epoxy adhesive for end fixing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Reference Mark and Limit Switch Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe RGS40-S system supports additional magnetic actuators for reference positioning and travel-limit detection. These accessories work with compatible sensing functions inside the readhead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA. Reference Mark Actuators\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9531-0250\u003c\/td\u003e\n\u003ctd\u003eAdhesive \/ epoxy mounted\u003c\/td\u003e\n\u003ctd\u003eMagnetic reference actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9531-0287\u003c\/td\u003e\n\u003ctd\u003eScrew mounted\u003c\/td\u003e\n\u003ctd\u003eMagnetic reference actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9541-0037\u003c\/td\u003e\n\u003ctd\u003e90° adhesive or screw mounted\u003c\/td\u003e\n\u003ctd\u003eReference actuator for RGH24, RGH25, and RGH34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003eInstall one or more reference actuators at selected axis positions.\u003c\/li\u003e\n\u003cli\u003eThe magnetic actuator establishes a repeatable machine datum.\u003c\/li\u003e\n\u003cli\u003eThe reference output synchronizes with incremental channels.\u003c\/li\u003e\n\u003cli\u003eUnidirectional repeatability remains specified within the applicable operating conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eReference Repeatability Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRGS40-S Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Variation\u003c\/td\u003e\n\u003ctd\u003e±20 °C from installation temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnetic Field\u003c\/td\u003e\n\u003ctd\u003eSteady ±0.02 T or changing ±7.5 T\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Speed\u003c\/td\u003e\n\u003ctd\u003eRefer to the applicable readhead specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eB. Limit Switch Actuators\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9531-0251\u003c\/td\u003e\n\u003ctd\u003e10 mm adhesive-mounted magnetic actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9531-2052\u003c\/td\u003e\n\u003ctd\u003e24.35 mm adhesive-mounted magnetic actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9531-2054\u003c\/td\u003e\n\u003ctd\u003e50 mm adhesive-mounted magnetic actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9531-0285\u003c\/td\u003e\n\u003ctd\u003eFlush-mounted magnetic actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA-9541-0040\u003c\/td\u003e\n\u003ctd\u003e90° adhesive or screw-mounted actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eLimit Detection Characteristics:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection Method:\u003c\/strong\u003e Magnetic actuator sensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePosition:\u003c\/strong\u003e One or more selected travel positions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeatability:\u003c\/strong\u003e 0.1 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePurpose:\u003c\/strong\u003e Provides position-related limit detection for compatible control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility Warning:\u003c\/strong\u003e Actuator mounting and sensing arrangements vary by readhead model. Confirm the accessory part number against the exact RGH34 or RGH41 configuration before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Readhead Compatibility and System Selection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSelection Notes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRGH34\u003c\/td\u003e\n\u003ctd\u003e40 µm RGS40-S scale\u003c\/td\u003e\n\u003ctd\u003eConfirm output and reference options.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRGH41\u003c\/td\u003e\n\u003ctd\u003e40 µm RGS40-S scale\u003c\/td\u003e\n\u003ctd\u003eConfirm electrical interface and actuator arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRGH22\u003c\/td\u003e\n\u003ctd\u003eNot the specified pairing\u003c\/td\u003e\n\u003ctd\u003eDesigned for the 20 µm RGS20 scale family.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRGH24 \/ RGH25\u003c\/td\u003e\n\u003ctd\u003eNot the specified pairing\u003c\/td\u003e\n\u003ctd\u003eCheck the corresponding scale family before selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Selection Rule:\u003c\/strong\u003e Match the scale pitch with the readhead's optical system. A 40 µm scale requires the corresponding RGS40-compatible readhead configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | RGS40-S vs. RGS40-PC: Material Selection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComparison\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRGS40-S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRGS40-PC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Pitch\u003c\/td\u003e\n\u003ctd\u003e40 µm\u003c\/td\u003e\n\u003ctd\u003e40 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Material\u003c\/td\u003e\n\u003ctd\u003eGold-plated steel\u003c\/td\u003e\n\u003ctd\u003eGold-plated steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurface Protection\u003c\/td\u003e\n\u003ctd\u003eProtective lacquer\u003c\/td\u003e\n\u003ctd\u003eProtective polyester coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e±3 µm\/m\u003c\/td\u003e\n\u003ctd\u003e±5 µm\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Linearity\u003c\/td\u003e\n\u003ctd\u003e±1 µm\/60 mm\u003c\/td\u003e\n\u003ctd\u003e±1.5 µm\/60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadhead Compatibility\u003c\/td\u003e\n\u003ctd\u003eRGH34, RGH41\u003c\/td\u003e\n\u003ctd\u003eRGH41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Selection\u003c\/td\u003e\n\u003ctd\u003eStandard precision applications\u003c\/td\u003e\n\u003ctd\u003eApplications requiring improved chemical resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eChoose \u003cstrong\u003eRGS40-S\u003c\/strong\u003e when scale linearity is the primary selection requirement. Consider \u003cstrong\u003eRGS40-PC\u003c\/strong\u003e when exposure to harsh solvents requires additional surface protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Environmental and Maintenance Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -10 °C to +120 °C for the scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Temperature:\u003c\/strong\u003e Minimum +10 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubstrate:\u003c\/strong\u003e Compatible metals, granite, ceramics, and composites.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface Condition:\u003c\/strong\u003e Clean, stable, and suitable for adhesive bonding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChemical Exposure:\u003c\/strong\u003e Avoid aggressive solvents on the lacquered surface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspection:\u003c\/strong\u003e Check for adhesive lifting, surface damage, and contamination.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUse compatible cleaning materials and follow the manufacturer's installation instructions. Avoid acetone, chlorinated solvents, and methylated spirits on the scale.\u003c\/p\u003e\n\u003cp\u003eFor applications involving aggressive solvents or lubricants, evaluate the RGS40-PC polyester-coated alternative.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Certification and Documentation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe supplied specifications identify the material, dimensions, measurement pitch, and operating limits. They do not establish a separate product-specific certification declaration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRequest the applicable Renishaw technical datasheet.\u003c\/li\u003e\n\u003cli\u003eConfirm installation requirements against the official scale guide.\u003c\/li\u003e\n\u003cli\u003eVerify machine-level compliance with the relevant industrial standards.\u003c\/li\u003e\n\u003cli\u003eRequest product identification and traceability documentation when required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Package Contents and Supply Options\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003eRenishaw RGS40-S\u003c\/strong\u003e reflective steel tape scale.\u003c\/li\u003e\n\u003cli\u003eSpecified cut length according to the purchase order.\u003c\/li\u003e\n\u003cli\u003eSelf-adhesive backing supplied with the scale.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCut-to-length supply from 100 mm to 50 m.\u003c\/li\u003e\n\u003cli\u003eLengths above 50 m require special-order confirmation.\u003c\/li\u003e\n\u003cli\u003eReference actuators and limit actuators require separate selection.\u003c\/li\u003e\n\u003cli\u003eEnd clamps and epoxy adhesive should be specified separately.\u003c\/li\u003e\n\u003cli\u003eReadheads are not included unless the order explicitly states otherwise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e11 | Engineering FAQ and Purchasing Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How should engineers calculate the required RGS40-S scale length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart with the machine's measuring travel, then check the readhead's installation geometry and end-fixing allowance. The complete scale length must accommodate the measuring range and required installation margins. Do not order using the nominal axis travel alone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What happens if the mounting surface has poor flatness?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLocal surface irregularities can affect tape adhesion and readhead alignment. They may also introduce unwanted ride-height variation. Inspect and prepare the substrate before applying the scale. Follow the readhead installation drawing for surface and alignment tolerances.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can the RGS40-S be installed on an aluminum machine bed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, provided the substrate meets the specified expansion-coefficient range and installation requirements. The thin tape follows the substrate's thermal behavior after correct bonding and end fixing. Always verify the actual machine material and mounting conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: When should a machine builder select RGS40-PC instead?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChoose RGS40-PC when the scale faces greater exposure to aggressive cleaning chemicals or lubricants. Its polyester coating improves chemical resistance. However, its specified linearity differs from RGS40-S. Compare measurement requirements before changing the material configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What information should buyers provide when requesting a replacement scale?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the existing scale model, required measuring length, readhead model, substrate material, and operating temperature. Also identify the required reference and limit functions. These details help prevent pitch mismatches and incorrect accessory selection.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Renishaw","offers":[{"title":"Default Title","offer_id":68155460157622,"sku":"RGS40-S","price":186.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/RGS20-S2-3.jpg?v=1795578128","url":"https:\/\/www.plcsparehub.com\/products\/rgs40-s-renishaw-40%c2%b5m-gold-steel-encoder-tape","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}