{"product_id":"renishaw-rgh22b30l00a-rg2-1vpp-incremental-encoder-read-head","title":"Renishaw RGH22B30L00A RG2 1Vpp Incremental Encoder Read Head","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eRenishaw RGH22B30L00A\u003c\/span\u003e\u003c\/strong\u003e is a non-contact incremental optical readhead from the \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eRG2 series\u003c\/span\u003e\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt reads position information from a compatible linear scale without mechanical contact. Its optical sensing system supports accurate motion feedback in precision positioning applications.\u003c\/p\u003e\n\u003cp\u003eThis configuration provides \u003cstrong\u003e1 Vpp differential analog output\u003c\/strong\u003e, single-limit sensing, and a 3-meter cable. It connects to compatible motion controllers and encoder interface systems through a 15-pin D-type connector.\u003c\/p\u003e\n\u003cp\u003eThe readhead typically operates with the \u003cstrong\u003eRenishaw RGS20-S gold-plated steel scale\u003c\/strong\u003e, which features a 20 µm scale pitch. Engineers can use this combination in semiconductor equipment, precision machine tools, electronic assembly systems, and automated inspection equipment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRenishaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRGH22B30L00A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRG2\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIncremental Optical Linear Encoder Readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensing Technology\u003c\/td\u003e\n\u003ctd\u003eNon-contact optical measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e1 Vpp differential analog signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLimit Detection\u003c\/td\u003e\n\u003ctd\u003eSingle-limit sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Compatibility\u003c\/td\u003e\n\u003ctd\u003eRGS20-S gold-plated steel scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Pitch\u003c\/td\u003e\n\u003ctd\u003e20 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Speed\u003c\/td\u003e\n\u003ctd\u003eUp to 10 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e15-pin D-type analog connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Configuration\u003c\/td\u003e\n\u003ctd\u003eStandard alarm-line configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Bracket\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × L × W)\u003c\/td\u003e\n\u003ctd\u003e14.8 × 36.0 × 13.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ordering code identifies the readhead configuration and electrical connection.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRGH22:\u003c\/strong\u003e RG2 optical readhead with integrated signal processing and reference functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB:\u003c\/strong\u003e 1 Vpp differential analog output with single-limit sensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30:\u003c\/strong\u003e 3.0-meter cable configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eL:\u003c\/strong\u003e 15-pin D-type connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00:\u003c\/strong\u003e Standard alarm-line configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA:\u003c\/strong\u003e Readhead supplied without a mounting bracket.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Note:\u003c\/strong\u003e Verify the complete suffix before ordering. Connector, cable, limit sensing, and mounting arrangements affect system compatibility.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMeasurement Performance and Signal Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Principle:\u003c\/strong\u003e Optical incremental position detection provides non-contact motion feedback.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Output:\u003c\/strong\u003e Differential 1 Vpp analog signals support compatible encoder interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotion Capability:\u003c\/strong\u003e Maximum operating speed reaches 10 m\/s under suitable system conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePosition Resolution:\u003c\/strong\u003e The final resolution depends on the receiving controller's interpolation electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScale Pitch:\u003c\/strong\u003e The recommended RGS20-S scale uses a 20 µm graduation pitch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReference Function:\u003c\/strong\u003e Integrated reference sensing supports repeatable machine-axis referencing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLimit Function:\u003c\/strong\u003e Single-limit sensing provides an additional axis-position detection function.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Note:\u003c\/strong\u003e The 20 µm scale pitch does not represent the final machine positioning resolution. Controller interpolation determines the effective digital resolution.\u003c\/p\u003e\n\u003cp\u003eSpecific linearity, signal frequency limits, interpolation accuracy, and electrical noise immunity require confirmation against the applicable Renishaw technical documentation. Do not treat the maximum speed as a guaranteed operating speed under every controller configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the scale:\u003c\/strong\u003e Check the RGS20-S surface for contamination, scratches, and installation damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrepare the mounting surface:\u003c\/strong\u003e Ensure the machine mounting face remains clean and stable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall the readhead:\u003c\/strong\u003e Secure the RGH22B30L00A using a compatible mounting arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet the alignment:\u003c\/strong\u003e Follow Renishaw installation specifications for readhead height, pitch, roll, and yaw.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoute the cable:\u003c\/strong\u003e Keep the 3-meter cable away from motor power lines and high-current switching circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect the interface:\u003c\/strong\u003e Match the 15-pin D-type connector and signal assignments with the controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the supply:\u003c\/strong\u003e Confirm a stable 5 V ±5% power supply before commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e This model does not include a mounting bracket. Confirm the required mounting hardware before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe integrated alignment LED simplifies initial setup and optical signal adjustment.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the LED indication during initial readhead alignment.\u003c\/li\u003e\n\u003cli\u003eVerify the 1 Vpp differential output with compatible measurement equipment.\u003c\/li\u003e\n\u003cli\u003eConfirm reference and single-limit signals during axis commissioning.\u003c\/li\u003e\n\u003cli\u003eMove the axis slowly and inspect signal stability across the travel range.\u003c\/li\u003e\n\u003cli\u003eCheck connector engagement and cable routing during scheduled maintenance.\u003c\/li\u003e\n\u003cli\u003eClean the optical area using an approved method when contamination affects signal quality.\u003c\/li\u003e\n\u003cli\u003eInvestigate intermittent feedback before adjusting controller interpolation settings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eStable optical alignment helps prevent position feedback errors. Proper cable separation also reduces electrical interference risks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility and Application Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Component\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility Considerations\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Scale\u003c\/td\u003e\n\u003ctd\u003eRGS20-S gold-plated steel scale with 20 µm pitch.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotion Controller\u003c\/td\u003e\n\u003ctd\u003eRequires a compatible 1 Vpp differential encoder input.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eProvides regulated 5 V ±5% power.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Interface\u003c\/td\u003e\n\u003ctd\u003eRequires a matching 15-pin D-type connection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLimit Input\u003c\/td\u003e\n\u003ctd\u003eController must support the specified single-limit sensing arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hardware\u003c\/td\u003e\n\u003ctd\u003eRequires a suitable mounting bracket or approved mounting solution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemiconductor wafer positioning and precision handling equipment.\u003c\/li\u003e\n\u003cli\u003eCNC machine tools and high-accuracy linear positioning axes.\u003c\/li\u003e\n\u003cli\u003eElectronic component placement and assembly machinery.\u003c\/li\u003e\n\u003cli\u003eAutomated optical inspection and measurement systems.\u003c\/li\u003e\n\u003cli\u003eIndustrial motion stages requiring incremental position feedback.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Conditions and Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 °C to +55 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP50 under the specified protection classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Environment:\u003c\/strong\u003e Use in clean, controlled industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContamination Control:\u003c\/strong\u003e Protect the optical sensing area from dust, oil, and machining debris.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Protection:\u003c\/strong\u003e Use appropriate cable routing and grounding practices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIP50 does not provide protection against water ingress. Avoid direct exposure to coolant, washdown, and conductive contamination.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCertification and Compliance Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe available configuration information does not establish specific certifications for \u003cstrong\u003eRGH22B30L00A\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eContact us for applicable manufacturer documentation, product identification details, and compliance information. Verify installation requirements against the complete machine-system standards.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Renishaw RGH22B30L00A RG2 optical linear encoder readhead.\u003c\/li\u003e\n\u003cli\u003eIntegrated 3.0-meter cable.\u003c\/li\u003e\n\u003cli\u003e15-pin D-type connector configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The mounting bracket and RGS20-S scale are not included unless the order explicitly specifies them.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the RGH22B30L00A connect directly to a PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot to every standard PLC input. This readhead provides 1 Vpp differential analog signals. The PLC or motion controller needs a compatible encoder interface or signal conversion module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does a 20 µm scale pitch mean the positioning resolution is 20 µm?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The scale pitch defines the optical graduation spacing. The receiving interpolation electronics determine the final digital resolution. Check the controller's interpolation ratio before calculating axis positioning accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What should engineers check when the position signal becomes unstable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart with optical alignment and scale cleanliness. Then inspect the 5 V supply, connector contacts, cable routing, and differential signal quality. Check motor drive interference if the fault appears during acceleration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can this readhead operate without the RGS20-S scale?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt requires a compatible optical scale. The RGS20-S is the specified matching scale in this configuration. Confirm scale compatibility before replacing an existing encoder assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How should buyers distinguish this model from other RG2 readheads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the complete ordering code rather than the RGH22 family designation alone. This model specifies 1 Vpp output, single-limit sensing, a 3-meter cable, and a 15-pin D-type connector. It also excludes the mounting bracket.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/RGH22.png?v=1795576438\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Renishaw","offers":[{"title":"Default Title","offer_id":68155192508598,"sku":"RGH22B30L00A","price":106.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/RGH22B30L00A-3.jpg?v=1795576415","url":"https:\/\/www.plcsparehub.com\/products\/renishaw-rgh22b30l00a-rg2-1vpp-incremental-encoder-read-head","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}