{"product_id":"rdio-01-abb-acs800-digital-i-o-extension-module","title":"RDIO-01 ABB ACS800 Digital I\/O Extension Module","description":"\u003ch2\u003e\u003cstrong\u003eABB RDIO-01 Digital I\/O Extension Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB RDIO-01\u003c\/strong\u003e expands the digital signal interface of compatible ABB drives. It provides \u003cstrong\u003ethree digital inputs and two relay outputs\u003c\/strong\u003e for drive status monitoring, external control signals, and relay-based interlocking.\u003c\/p\u003e\n\u003cp\u003eThe module accepts both DC and AC input signals. Its inputs support \u003cstrong\u003e24–250 V DC or 110–230 V AC\u003c\/strong\u003e, allowing integration with different industrial control circuits. Two relay outputs handle switching duties for external devices and control systems.\u003c\/p\u003e\n\u003cp\u003eDesigned for compatible ABB drive platforms, the \u003cstrong\u003eRDIO-01 digital I\/O extension module\u003c\/strong\u003e installs into an RMIO board option slot or an external AIMA-01 I\/O Module Adapter. A 38-pin connector establishes the module's signal and power connection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | I\/O Architecture at a Glance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003cth\u003eQuantity\u003c\/th\u003e\n\u003cth\u003eElectrical Capability\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital inputs\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e24–250 V DC or 110–230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay outputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eUp to 250 V AC or 120 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC input logic\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eON above 12 V; OFF below 8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC input logic\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eON above 40 V; OFF below 20 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput filtering\u003c\/td\u003e\n\u003ctd\u003eSelectable\u003c\/td\u003e\n\u003ctd\u003eON: 5–10 ms; OFF: 2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput update interval\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eMinimum 12 ms in ACS800 Standard Application Program\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation voltage\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e2.5 kV AC; 1.5 kV AC between DI2 and DI3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Digital Input Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThree input channels\u003c\/strong\u003e accept industrial AC or DC signals. Their electrical thresholds support reliable state recognition within the specified input range.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC input voltage\u003c\/td\u003e\n\u003ctd\u003e24–250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC input voltage\u003c\/td\u003e\n\u003ctd\u003e110–230 V AC ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC input current\u003c\/td\u003e\n\u003ctd\u003e4–10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC input current\u003c\/td\u003e\n\u003ctd\u003eMaximum 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC logic 0\u003c\/td\u003e\n\u003ctd\u003eBelow 8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC logic 1\u003c\/td\u003e\n\u003ctd\u003eAbove 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC logic 0\u003c\/td\u003e\n\u003ctd\u003eBelow 20 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC logic 1\u003c\/td\u003e\n\u003ctd\u003eAbove 40 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter time\u003c\/td\u003e\n\u003ctd\u003eON: 5–10 ms; OFF: 2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach input has a selectable hardware-filter setting. Three green LEDs indicate the individual input states.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation arrangement:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDI1 has galvanic isolation from DI2, DI3, relay outputs, and the power supply.\u003c\/li\u003e\n\u003cli\u003eDI2 and DI3 form a separate isolation group.\u003c\/li\u003e\n\u003cli\u003eDI2 and DI3 also have galvanic isolation from each other.\u003c\/li\u003e\n\u003cli\u003eIsolation test voltage: 2.5 kV AC for DI1 and the DI2\/DI3 group.\u003c\/li\u003e\n\u003cli\u003eIsolation test voltage between DI2 and DI3: 1.5 kV AC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Relay Output and Contact Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe two relay channels, RO1 and RO2, provide isolated switching interfaces for external control circuits. Their contact ratings must match the connected load.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum contact voltage\u003c\/td\u003e\n\u003ctd\u003e250 V AC \/ 120 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous current\u003c\/td\u003e\n\u003ctd\u003e2 A RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e5 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC switching capability\u003c\/td\u003e\n\u003ctd\u003e8 A at 24 V DC, resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC switching capability\u003c\/td\u003e\n\u003ctd\u003e0.4 A at 120 V DC, resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC switching capability\u003c\/td\u003e\n\u003ctd\u003e2000 VA at 250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact material\u003c\/td\u003e\n\u003ctd\u003eSilver cadmium oxide (AgCdO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact protection\u003c\/td\u003e\n\u003ctd\u003e250 V varistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation test voltage\u003c\/td\u003e\n\u003ctd\u003e2.5 kV RMS, 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eApplication note:\u003c\/strong\u003e Do not select relay contacts solely by their maximum resistive rating. Motor starting current and inductive energy may require an appropriately rated interposing relay or contactor.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Power Supply, Construction and Environmental Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power consumption\u003c\/td\u003e\n\u003ctd\u003e150 mA at 5 V + 30 mA at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower source\u003c\/td\u003e\n\u003ctd\u003eRMIO board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEstimated minimum lifetime\u003c\/td\u003e\n\u003ctd\u003e100,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet dimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e22.5 × 5.2 × 15.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRMIO option slot or AIMA-01 adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain bus connection\u003c\/td\u003e\n\u003ctd\u003e38-pin parallel bus connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField wiring terminals\u003c\/td\u003e\n\u003ctd\u003eFour non-detachable screw-type terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum wire cross-section\u003c\/td\u003e\n\u003ctd\u003e2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial compliance\u003c\/td\u003e\n\u003ctd\u003eUL\/CSA-approved materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC standards\u003c\/td\u003e\n\u003ctd\u003eEN 50081-2 and EN 50082-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe module receives both operating voltages from the RMIO board. Check the drive's available power capacity before adding the option.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Hardware Configuration and Drive Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe RDIO-01 supports two installation arrangements:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect drive installation:\u003c\/strong\u003e Insert the module into SLOT 1 or SLOT 2 on the RMIO board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal I\/O installation:\u003c\/strong\u003e Mount the module through an AIMA-01 I\/O Module Adapter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration Item\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRotary switch\u003c\/td\u003e\n\u003ctd\u003eNode ID selection, range 1–15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput DIP switches\u003c\/td\u003e\n\u003ctd\u003eEnable or disable hardware filtering for each digital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e38-pin connector\u003c\/td\u003e\n\u003ctd\u003eSignal and power connection to the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRetaining clips\u003c\/td\u003e\n\u003ctd\u003eSecure the module in the RMIO option slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting screws\u003c\/td\u003e\n\u003ctd\u003eSecure the module and provide I\/O cable shield earthing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe two mounting screws also connect the module GND signals with the RMIO board. Tighten both screws correctly to maintain the intended grounding arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Installation and Commissioning Procedure\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eIsolate the drive from its power source before installation.\u003c\/li\u003e\n\u003cli\u003eIdentify the designated SLOT 1 or SLOT 2 position on the RMIO board.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the 38-pin connector and insert it carefully.\u003c\/li\u003e\n\u003cli\u003ePress until the retaining clips engage securely.\u003c\/li\u003e\n\u003cli\u003eFasten both screws to the mounting stand-offs.\u003c\/li\u003e\n\u003cli\u003eRemove the module enclosure cover.\u003c\/li\u003e\n\u003cli\u003eSet the node ID and input-filter DIP switches as required.\u003c\/li\u003e\n\u003cli\u003eRefit the enclosure cover and inspect the field wiring.\u003c\/li\u003e\n\u003cli\u003eRestore drive power and observe the diagnostic LEDs.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eCheck the drive hardware manual for the applicable installation and safety requirements. Confirm terminal assignments before connecting field signals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Diagnostic LEDs and Fault Isolation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe RDIO-01 uses four diagnostic LEDs to help engineers assess module operation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLED\u003c\/th\u003e\n\u003cth\u003eIndication\u003c\/th\u003e\n\u003cth\u003eEngineering Interpretation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDI1–DI3\u003c\/td\u003e\n\u003ctd\u003eGreen, ON\u003c\/td\u003e\n\u003ctd\u003eCorresponding input is at logical 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus\u003c\/td\u003e\n\u003ctd\u003eYellow, ON during startup\u003c\/td\u003e\n\u003ctd\u003eDrive is configuring the module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus remains ON beyond one second\u003c\/td\u003e\n\u003ctd\u003eConfiguration does not complete\u003c\/td\u003e\n\u003ctd\u003eCheck installation and communication conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eFor direct RMIO slot installation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCycle the drive power supply and observe the startup sequence again.\u003c\/li\u003e\n\u003cli\u003eCheck that the 38-pin connector is fully seated.\u003c\/li\u003e\n\u003cli\u003eIf the fault persists, investigate a possible module hardware failure.\u003c\/li\u003e\n\u003cli\u003eContact an ABB service representative when necessary.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor AIMA-01 adapter installation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm that the drive has power.\u003c\/li\u003e\n\u003cli\u003eVerify the selected node ID.\u003c\/li\u003e\n\u003cli\u003eCheck fibre-optic transmitter-to-receiver connections.\u003c\/li\u003e\n\u003cli\u003eInspect fibre connectors for contamination or incomplete insertion.\u003c\/li\u003e\n\u003cli\u003eExamine fibre cables for visible damage.\u003c\/li\u003e\n\u003cli\u003eReseat the 38-pin connector.\u003c\/li\u003e\n\u003cli\u003eSubstitute known-good fibre cables if communication remains unavailable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/RDIO-01.png?v=1795162497\" alt=\"\"\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68112842260662,"sku":"RDIO-01","price":106.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/RDIO-01-1.jpg?v=1795162497","url":"https:\/\/www.plcsparehub.com\/products\/rdio-01-abb-acs800-digital-i-o-extension-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}