{"product_id":"provibtech-tr4101-a02-e01-g00-s01-shaft-vibration-loop-transmitter","title":"ProvibTech TR4101-A02-E01-G00-S01 Shaft Vibration Loop Transmitter","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eProvibTech TR4101-A02-E01-G00-S01\u003c\/strong\u003e acts as an integrated proximity probe driver and signal conditioner.\u003c\/p\u003e\n\u003cp\u003eThis unit provides a cost-effective solution for monitoring radial shaft vibration on critical industrial machinery.\u003c\/p\u003e\n\u003cp\u003eThe loop-powered design eliminates the need for external drivers.\u003c\/p\u003e\n\u003cp\u003eIt delivers a direct 4-20mA output for your control systems.\u003c\/p\u003e\n\u003cp\u003eThe copper-free aluminum casted case features robust epoxy potting.\u003c\/p\u003e\n\u003cp\u003eThis construction ensures high reliability in harsh plant environments.\u003c\/p\u003e\n\u003cp\u003eEngineers get continuous asset protection and simplified field wiring in a compact footprint.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eProvibTech TR4101 Series\u003c\/strong\u003e excels at simplifying turbomachinery protection architectures.\u003c\/p\u003e\n\u003cp\u003eTraditional proximity systems require separate drivers and transmitters.\u003c\/p\u003e\n\u003cp\u003eThis specific hardware integrates both elements into a single enclosure.\u003c\/p\u003e\n\u003cp\u003eThis integration reduces cabinet space requirements and cuts installation labor costs significantly.\u003c\/p\u003e\n\u003cp\u003eThe buffered output allows raw vibration data collection without interrupting the primary control loop.\u003c\/p\u003e\n\u003cp\u003eMaintenance teams can easily connect portable diagnostic analyzers for detailed dynamic analysis.\u003c\/p\u003e\n\u003cp\u003eIt serves as a highly reliable interface for balance-of-plant machinery protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ProvibTech\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003eTR4101-A02-E01-G00-S01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 to 100um (4.0mil) peak-to-peak full scale shaft vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e 2.0Hz to 3,000Hz within a 3dB variance window.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Output:\u003c\/strong\u003e 2-wire 4-20mA loop-powered analog current output proportional to overall vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e 8.0mV\/um (200mV\/mil) nominal sensitivity rating for precise measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuffered Output:\u003c\/strong\u003e Un-filtered original vibration signal output with 2-18VDC nominal GAP voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Impedance:\u003c\/strong\u003e 20 kΩ output impedance on the buffered diagnostic channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Cable Distance:\u003c\/strong\u003e 3.0 meters (10 feet) maximum distance for the buffered signal cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Accepts a wide 16 to 30VDC input voltage range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40 degrees Celsius to +70 degrees Celsius operational range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 degrees Celsius to +100 degrees Celsius maximum storage limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e 90% non-condensing relative humidity resistance during operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e Epoxy-potted copper-free aluminum casted housing protects internal circuits from humidity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProximity Probes:\u003c\/strong\u003e Fully compatible with standard 5mm, 8mm, and 11mm proximity probes from major industrial brands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Match:\u003c\/strong\u003e Designed specifically for seamless integration with the TM0180 8mm probe and 9m extension cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Systems:\u003c\/strong\u003e Integrates directly with Distributed Control Systems (DCS), Programmable Logic Controllers (PLC), and standard supervisory monitors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Configuration:\u003c\/strong\u003e Install the transmitter firmly onto a standard 35mm DIN rail inside a protective field enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Sequence:\u003c\/strong\u003e Connect the 2-wire loop power cables directly to the designated positive and negative terminal blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Connection:\u003c\/strong\u003e Attach the extension cable from the 8mm probe to the specialized proximity input terminal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistance Constraint:\u003c\/strong\u003e Keep the buffered output cable length under 3.0 meters to prevent dynamic signal degradation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCalibration and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGAP Voltage Verification:\u003c\/strong\u003e Measure the DC voltage across the buffered output to verify correct physical probe clearance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Testing:\u003c\/strong\u003e Inject a known current signal to verify loop integrity and control room display scaling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoutine Inspection:\u003c\/strong\u003e Check terminal connections annually for tightness and inspect the enclosure for signs of physical damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTarget Equipment Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Tower Fans:\u003c\/strong\u003e Monitors shaft vibration to detect blade unbalance and mechanical looseness early.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCentrifugal Pumps:\u003c\/strong\u003e Tracks radial shaft displacement to prevent mechanical seal failures and bearing damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Compressors:\u003c\/strong\u003e Provides continuous monitoring of high-speed shafts to prevent catastrophic internal contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Motors:\u003c\/strong\u003e Safeguards large induction motors against rotor dynamic instability and structural misalignment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRaw Vibration Access:\u003c\/strong\u003e The buffered output provides un-filtered dynamic signals for detailed fast Fourier transform analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrbit Analysis:\u003c\/strong\u003e Allows machinery specialists to map shaft centerline motion using orthogonal proximity probe setups.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC GAP Tracking:\u003c\/strong\u003e Measures physical distance changes to monitor steady-state shaft position and bearing wear trends.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCertification Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Rating:\u003c\/strong\u003e Multiple international hazardous area certifications for explosive atmosphere installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Compliance:\u003c\/strong\u003e Rated II 1 G EEx ia IIC T4 intrinsic safety verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Spec:\u003c\/strong\u003e Intrinsic safety certified for ambient temperatures from -40 degrees Celsius to +70 degrees Celsius.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Commercial Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging List:\u003c\/strong\u003e Includes one factory-sealed transmitter module and an official product installation sheet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Coverage:\u003c\/strong\u003e Includes a comprehensive 12-month factory warranty against manufacturing and material defects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Time:\u003c\/strong\u003e Ready for shipment within 24 to 48 hours from order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCourier Delivery:\u003c\/strong\u003e Ships globally via premium express couriers including FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eBuying Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdentify Full Scale:\u003c\/strong\u003e Verify if the A02 0-100um range matches your machine manufacturer asset protection specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck Probe Match:\u003c\/strong\u003e Confirm your existing field probe matches the E01 option code before final installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify Area Classification:\u003c\/strong\u003e Ensure the S01 ATEX rating matches the hazardous zone classification of your plant floor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the A02 code represent on this device?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe A02 code specifies a factory measurement range of 0 to 100 micrometers peak-to-peak vibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this transmitter require a separate proximity probe driver?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the internal circuit combines the driver and transmitter functions into one single housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I connect this module directly to a standard PLC analog card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 2-wire 4-20mA output connects directly to standard analog input cards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I check the position of the probe using this device?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMeasure the DC voltage at the buffered output to determine the real-time sensor GAP value.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if my extension cable exceeds 9 meters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe E01 configuration requires a 9-meter system length to maintain calibrated measurement accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/TR4101.png?v=1783931605\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45258376839350,"sku":"TR4101-A02-E01-G00-S01","price":152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/TR4101-A02-E01-G00-S01.jpg?v=1783928436","url":"https:\/\/www.plcsparehub.com\/products\/provibtech-tr4101-a02-e01-g00-s01-shaft-vibration-loop-transmitter","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}