{"product_id":"provibtech-tm0180-01-05-35-10-02-8mm-proximity-probe","title":"ProvibTech TM0180-01-05-35-10-02 8mm Proximity Probe","description":"\u003ch3\u003e\u003cb\u003eProduct Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1673b8;\"\u003eProvibTech TM0180-01-05-35-10-02\u003c\/span\u003e\u003c\/strong\u003e is a standard 8mm proximity probe for industrial machinery monitoring.\u003c\/p\u003e\n\u003cp\u003eIt belongs to the \u003cstrong\u003eTM0180 8mm proximity probe series\u003c\/strong\u003e. The probe measures shaft displacement and vibration through non-contact electromagnetic sensing.\u003c\/p\u003e\n\u003cp\u003eThis configuration features an \u003cstrong\u003eM10×1 mounting thread\u003c\/strong\u003e and an unarmored probe cable. It has a 0.5-inch unthreaded length and a 1.0-meter total cable length.\u003c\/p\u003e\n\u003cp\u003eProvibTech designed the TM0180 series for demanding industrial environments. Its rugged cable jacket resists tearing, mechanical damage, and corrosive exposure. This construction helps reduce electrical isolation problems during long-term operation.\u003c\/p\u003e\n\u003cp\u003eA protective rubber boot covers the connector interface. It helps prevent oil, dirt, and other contaminants from entering the connection.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProvibTech\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #1673b8;\"\u003eTM0180-01-05-35-10-02\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eTM0180 8mm Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eStandard 8mm Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Type\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003eM10×1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor\u003c\/td\u003e\n\u003ctd\u003eWithout Armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0.5 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e3.5 mm (35 configuration code)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Configuration\u003c\/td\u003e\n\u003ctd\u003eCode 02 – Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e-23 to -30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003eLess than 12 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0.25 to 2.25 mm (10 to 90 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarting Measurement Point\u003c\/td\u003e\n\u003ctd\u003e0.25 mm (10 mils) from probe face\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e7.87 mV\/μm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003eWithin ±0.0254 mm (±1.0 mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Linearity\u003c\/td\u003e\n\u003ctd\u003e±0.038 mm (±1.5 mil), including interchangeability errors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10.0 kHz (±3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n\u003ctd\u003e15 mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Driver Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Driver Storage Temperature\u003c\/td\u003e\n\u003ctd\u003e-50°C to +100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +177°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension Cable Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +177°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e100%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDriver Mounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail or plate mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDriver Height\u003c\/td\u003e\n\u003ctd\u003e75 mm (2.95 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Note:\u003c\/strong\u003e The specified 2.0 mm linear range starts at 0.25 mm from the probe face. The measurement range and linear range describe different operating limits. The probe sensitivity supports displacement and vibration signal conversion.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eKey Features and Engineering Advantages\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8mm Non-Contact Measurement:\u003c\/strong\u003e Measures shaft displacement without direct mechanical contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Sensitivity:\u003c\/strong\u003e Provides 7.87 mV\/μm output sensitivity for machinery monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Frequency Response:\u003c\/strong\u003e Supports dynamic measurements up to 10 kHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Cable Construction:\u003c\/strong\u003e Resists cable tearing and environmental deterioration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e A rubber boot helps prevent oil and dirt penetration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation Considerations:\u003c\/strong\u003e Rugged cable protection helps reduce insulation-related installation problems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Driver Installation:\u003c\/strong\u003e Supports standard 35 mm DIN rail or plate mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Temperature Capability:\u003c\/strong\u003e The probe and extension cable support temperatures up to +177°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eMeasurement Performance and Signal Characteristics\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePerformance Item\u003c\/th\u003e\n\u003cth\u003eEngineering Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplacement Measurement\u003c\/td\u003e\n\u003ctd\u003eNon-contact shaft displacement measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffective Linear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated Sensitivity\u003c\/td\u003e\n\u003ctd\u003e7.87 mV\/μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity Deviation\u003c\/td\u003e\n\u003ctd\u003e±0.0254 mm from a straight line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Capability\u003c\/td\u003e\n\u003ctd\u003e0–10 kHz at ±3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensitivity\u003c\/td\u003e\n\u003ctd\u003eWithin ±0.3%\/°C in the middle of the linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensitivity at 2.25 mm\u003c\/td\u003e\n\u003ctd\u003eNominally ±0.5%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Reference\u003c\/td\u003e\n\u003ctd\u003eProbe and 5-meter cable system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e The temperature sensitivity figures refer to the specified probe and 5-meter cable calibration condition. Confirm the actual extension cable arrangement before applying these values to a complete measurement system.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eEnvironmental Resistance and Electrical Protection\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1673b8;\"\u003eTM0180 series\u003c\/span\u003e\u003c\/strong\u003e addresses common installation problems in industrial proximity measurement systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe rugged cable jacket helps prevent mechanical damage.\u003c\/li\u003e\n\u003cli\u003eThe cable construction resists corrosive environmental exposure.\u003c\/li\u003e\n\u003cli\u003eThe protective connector boot limits oil and dirt contamination.\u003c\/li\u003e\n\u003cli\u003eProper cable routing helps prevent grounding and insulation problems.\u003c\/li\u003e\n\u003cli\u003eStable connector protection supports reliable long-term signal transmission.\u003c\/li\u003e\n\u003cli\u003eThe probe supports 100% non-condensing humidity conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Recommendation:\u003c\/strong\u003e Avoid sharp bends, excessive pulling force, and contact with moving machinery. Inspect the cable jacket and connector boot during scheduled maintenance.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTypical Industrial Applications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteam Turbines:\u003c\/strong\u003e Shaft vibration and radial displacement monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Turbines:\u003c\/strong\u003e Non-contact shaft movement measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Compressors:\u003c\/strong\u003e Monitoring shaft vibration and operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCentrifugal Pumps:\u003c\/strong\u003e Detecting abnormal shaft displacement and vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Motors:\u003c\/strong\u003e Monitoring shaft movement and mechanical stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGearboxes:\u003c\/strong\u003e Supporting vibration analysis and machinery condition assessment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotating Machinery:\u003c\/strong\u003e Continuous shaft position and vibration measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eInstallation Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eCorrect installation directly affects measurement accuracy and long-term signal stability.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the Model:\u003c\/strong\u003e Verify the complete part number and M10×1 mounting configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the Probe:\u003c\/strong\u003e Check the sensing tip, cable jacket, and connector boot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrepare the Target:\u003c\/strong\u003e Confirm the shaft material and minimum target diameter of 15 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall the Probe:\u003c\/strong\u003e Secure the probe using the specified mounting arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet the Gap:\u003c\/strong\u003e Adjust the probe gap according to the applicable calibration requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoute the Cable:\u003c\/strong\u003e Keep the cable away from power conductors and moving equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect the Driver:\u003c\/strong\u003e Verify polarity, supply voltage, and connector compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the Signal:\u003c\/strong\u003e Check the output voltage and confirm the measurement response.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Note:\u003c\/strong\u003e Use the manufacturer's installation instructions for final gap settings and calibration procedures. Do not assume that every monitor accepts the same probe configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eCommissioning, Diagnostics and Maintenance\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eCommissioning should verify the complete measurement chain. This includes the probe, extension cable, driver, and monitoring instrument.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInspection Item\u003c\/th\u003e\n\u003cth\u003eRecommended Check\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eVerify the -23 to -30 VDC supply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003eCheck that operating current remains below 12 mA.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Gap\u003c\/td\u003e\n\u003ctd\u003eConfirm the installed gap against the calibration specification.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eVerify sensitivity and output stability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Condition\u003c\/td\u003e\n\u003ctd\u003eInspect for cuts, abrasion, crushing, and chemical damage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Condition\u003c\/td\u003e\n\u003ctd\u003eCheck for oil, dirt, moisture, and loose connections.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding\u003c\/td\u003e\n\u003ctd\u003eInspect grounding arrangements and potential ground-loop paths.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Behavior\u003c\/td\u003e\n\u003ctd\u003eCompare monitoring readings with known machine operating conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePractical Diagnostic Guidance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUnstable readings may indicate poor connections or cable insulation damage.\u003c\/li\u003e\n\u003cli\u003eUnexpected zero readings may indicate incorrect wiring or power supply problems.\u003c\/li\u003e\n\u003cli\u003eSignal drift may indicate an incorrect probe gap or calibration mismatch.\u003c\/li\u003e\n\u003cli\u003eAbnormal vibration readings require comparison with independent machine measurements.\u003c\/li\u003e\n\u003cli\u003eRepeated signal interruptions require inspection of connectors and cable routing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eCompatibility and System Integration\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1673b8;\"\u003eProvibTech TM0180-01-05-35-10-02\u003c\/span\u003e\u003c\/strong\u003e is designed for 8mm proximity measurement applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm that the proximity driver supports the TM0180 probe characteristics.\u003c\/li\u003e\n\u003cli\u003eVerify the required operating voltage and electrical interface.\u003c\/li\u003e\n\u003cli\u003eCheck the extension cable length and connector configuration.\u003c\/li\u003e\n\u003cli\u003eConfirm the monitoring instrument supports the specified sensitivity.\u003c\/li\u003e\n\u003cli\u003eVerify the target material and measurement gap requirements.\u003c\/li\u003e\n\u003cli\u003eCheck the hazardous-area approval requirements before installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility Warning:\u003c\/strong\u003e Similar 8mm probes do not always share identical electrical characteristics. Do not replace another manufacturer's probe without checking the complete measurement chain.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eCertifications and Hazardous Area Approvals\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003cth\u003eApproval Information\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX – Probe Driver\u003c\/td\u003e\n\u003ctd\u003eII 1 G, EEx ia IIC T4, Ta = -40°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Certificate – Driver\u003c\/td\u003e\n\u003ctd\u003eKEMA06ATEX0217X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSA – Intrinsically Safe\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 1, Groups A, B, C and D, T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSA – Zone Classification\u003c\/td\u003e\n\u003ctd\u003eClass I, Zone 0, Ex ia IIC T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSA – Non-Incendive\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 2, Groups A, B, C and D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCEC\u003c\/td\u003e\n\u003ctd\u003eEx ia IIC T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGOST R\u003c\/td\u003e\n\u003ctd\u003e0ExiaIIC T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX – Probe and Cable\u003c\/td\u003e\n\u003ctd\u003eII 1 G, Ex ia IIC T4, Ta = -55°C to +115°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX – Probe and Cable\u003c\/td\u003e\n\u003ctd\u003eII 2 G, Ex ia IIC T2, Ta = -55°C to +232°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Certificate – Probe and Cable\u003c\/td\u003e\n\u003ctd\u003eKEMA07ATEX0110X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSA – Probe and Cable\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 1, Groups A, B, C and D, Ex ia IIC T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Notice:\u003c\/strong\u003e Hazardous-area approval depends on the complete certified system configuration. Verify the probe, cable, driver, associated apparatus, and installation conditions before use. Confirm the applicable certificate revision with the manufacturer.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eModel Number Configuration\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode Segment\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTM0180\u003c\/td\u003e\n\u003ctd\u003eStandard 8mm proximity probe series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eProbe type 01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e0.5-inch unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e3.5 mm case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0-meter total length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eConnector configuration: Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAlways check the complete part number before ordering. Each configuration code affects the mechanical installation or connection arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003ePackaging and Supply Information\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e ProvibTech TM0180-01-05-35-10-02 Standard 8mm Probe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e M10×1, without armor, 1.0 m total length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Feature:\u003c\/strong\u003e Connector protective rubber boot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Protective industrial packaging for transportation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month factory warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e FedEx, UPS, and DHL available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch:\u003c\/strong\u003e Estimated shipping within 24–48 hours after order confirmation, subject to stock availability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact our sales team to confirm stock, packaging details, delivery options, and product documentation before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eIn rotating machinery applications, proximity probe reliability depends on more than measurement sensitivity. Cable integrity, probe gap, target material, and system calibration all affect the final signal.\u003c\/p\u003e\n\u003cp\u003eFor example, a compressor may show unstable shaft vibration readings after maintenance. An engineer should first inspect the connector boot and cable jacket. Oil contamination or mechanical damage can affect electrical isolation and signal stability.\u003c\/p\u003e\n\u003cp\u003eThe next step involves checking the probe gap and supply voltage. The engineer should also verify the extension cable and monitor compatibility. Replacing the probe immediately may not solve an installation-related problem.\u003c\/p\u003e\n\u003cp\u003eFor the \u003cstrong\u003e\u003cspan style=\"color: #1673b8;\"\u003eTM0180-01-05-35-10-02\u003c\/span\u003e\u003c\/strong\u003e, the 1.0-meter cable configuration deserves particular attention. Confirm the complete measurement-chain requirements before connecting it to an existing monitor.\u003c\/p\u003e\n\u003cp\u003eOur engineering recommendation is simple: verify the mechanical, electrical, and certification requirements before procurement. This approach reduces replacement errors and helps improve machinery monitoring reliability.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What does the ProvibTech TM0180-01-05-35-10-02 measure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt measures shaft displacement and vibration through non-contact proximity sensing. It supports rotating machinery condition monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. What is the measurement range of this 8mm probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe specified measurement range is 0.25 to 2.25 mm. Its effective linear range is 2.0 mm. The specified sensitivity is 7.87 mV\/μm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Can this probe operate in high-temperature environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe probe and extension cable support -40°C to +177°C. The probe driver supports -40°C to +80°C during operation. Always verify the temperature limits of the complete installed system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. What should engineers check when vibration readings become unstable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart by inspecting the cable jacket and connector boot. Then verify the probe gap, supply voltage, grounding, and cable connections. Compare the signal with independent measurement data before replacing components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. How do I select the correct replacement for an existing proximity probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the probe diameter, mounting thread, cable length, connector type, sensitivity, and linear range. Also verify driver compatibility and hazardous-area approvals. A matching physical size alone does not guarantee electrical compatibility.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eRequest a Quote for ProvibTech TM0180-01-05-35-10-02\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eLooking for the \u003cstrong\u003e\u003cspan style=\"color: #1673b8;\"\u003eProvibTech TM0180-01-05-35-10-02\u003c\/span\u003e\u003c\/strong\u003e proximity probe?\u003c\/p\u003e\n\u003cp\u003eContact \u003cstrong\u003eGlobal PLC Spare HUB\u003c\/strong\u003e for pricing, availability, technical specifications, and delivery arrangements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompetitive industrial automation spare parts sourcing.\u003c\/li\u003e\n\u003cli\u003e12-month factory warranty.\u003c\/li\u003e\n\u003cli\u003eFedEx, UPS, and DHL shipping options.\u003c\/li\u003e\n\u003cli\u003eEstimated 24–48-hour dispatch after order confirmation, subject to availability.\u003c\/li\u003e\n\u003cli\u003eTechnical assistance for model and configuration verification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSend us your inquiry today for a quotation and delivery details.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/TM0180.png?v=1783929557\" alt=\"\"\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"ProSoft","offers":[{"title":"Default Title","offer_id":67980300746934,"sku":"TM0180-01-05-35-10-02","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/TM0180-07-00-04-10-02_d1172f52-616e-48d4-975d-72750645f819.jpg?v=1793605218","url":"https:\/\/www.plcsparehub.com\/products\/provibtech-tm0180-01-05-35-10-02-8mm-proximity-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}