{"product_id":"pr9268-202-000-epro-pr9268-series-vertical-velocity-transducer","title":"PR9268\/202-000 EPRO PR9268 Series Vertical Velocity Transducer","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003ePR9268\/202-000\u003c\/span\u003e Electrodynamic Vertical Velocity Module\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003eEPRO PR9268\/202-000\u003c\/span\u003e\u003c\/strong\u003e is a precision vibration transducer for continuous machinery condition monitoring.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor combines rugged mechanical construction with stable electrodynamic measurement technology.\u003c\/p\u003e\n\n\u003cp\u003eIts splash-proof housing supports operation inside harsh industrial process environments.\u003c\/p\u003e\n\n\u003cp\u003eThe module performs reliably in elevated temperatures up to 100°C.\u003c\/p\u003e\n\n\u003cp\u003eThe armored cable structure improves durability during long-term field installation.\u003c\/p\u003e\n\n\u003cp\u003eThis vibration sensor suits turbine systems, compressors, pumps, and rotating machinery diagnostics.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCore Monitoring Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eElectrodynamic vibration velocity measurement\u003c\/li\u003e\n\u003cli\u003eVertical installation configuration\u003c\/li\u003e\n\u003cli\u003eStable low-frequency response characteristics\u003c\/li\u003e\n\u003cli\u003eHigh resistance to industrial vibration stress\u003c\/li\u003e\n\u003cli\u003eOptimized sensitivity for machinery diagnostics\u003c\/li\u003e\n\u003cli\u003eRugged housing for demanding environments\u003c\/li\u003e\n\u003cli\u003eIP55 environmental protection capability\u003c\/li\u003e\n\u003cli\u003eSuitable for elevated operating temperatures\u003c\/li\u003e\n\u003cli\u003eLow linearity deviation performance\u003c\/li\u003e\n\u003cli\u003eReliable operation under EMC-compliant installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eConfiguration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth align=\"left\"\u003eConfiguration Segment\u003c\/th\u003e\n\u003cth align=\"left\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003ePR9268\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrodynamic vibration sensor series\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical measurement version\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eArmored 8-meter cable configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e000\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6-pole HARTING connector termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSuffix Structure Reference\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePR9268\/20x\u003c\/strong\u003e = Vertical measuring direction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA=2\u003c\/strong\u003e = Armored 8 m cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB00=000\u003c\/strong\u003e = HARTING connector version\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100\u003c\/strong\u003e = Open cable end option\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOPR\u003c\/strong\u003e = Oil-proof PTFE protective hose\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRAD\u003c\/strong\u003e = Radioactive environment version\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Performance Data\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e EPRO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003ePR9268\/202-000\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e PR9268 Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Electrodynamic Vertical Velocity Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e 4 Hz to 1000 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNatural Frequency:\u003c\/strong\u003e 4.5 Hz ±0.75 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e 28.5 mV\/(mm\/s) ±5%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity Error:\u003c\/strong\u003e Less than 2%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDamping Factor:\u003c\/strong\u003e 0.56 at 20°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransverse Sensitivity:\u003c\/strong\u003e 0.13 at 110 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Vibration Amplitude:\u003c\/strong\u003e 3000 µm peak-peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLimit Stops:\u003c\/strong\u003e 4000 µm peak-peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Acceleration:\u003c\/strong\u003e 10 g peak-peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Term Acceleration:\u003c\/strong\u003e 20 g peak-peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransverse Acceleration:\u003c\/strong\u003e 2 g peak-peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 1875 Ω ±10%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Greater than 1 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductance:\u003c\/strong\u003e Less than 90 mH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Less than 1.2 nF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP55\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +100°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Term Temperature:\u003c\/strong\u003e Up to 120°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +100°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e Al Mg Si Pb F28\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Type:\u003c\/strong\u003e 6-pole HARTING plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Weight:\u003c\/strong\u003e Approximately 260 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Weight:\u003c\/strong\u003e Approximately 930 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation Engineering Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eUse rigid and vibration-free mounting structures\u003c\/li\u003e\n\u003cli\u003eMaintain EMC-compliant cable routing practices\u003c\/li\u003e\n\u003cli\u003eSelect the smallest suitable measuring range\u003c\/li\u003e\n\u003cli\u003eConsider temperature and humidity during installation planning\u003c\/li\u003e\n\u003cli\u003eVerify trip limits with plant operating conditions\u003c\/li\u003e\n\u003cli\u003eInspect signal integrity before commissioning\u003c\/li\u003e\n\u003cli\u003eAvoid aggressive chemical contamination near the sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eContinuous vibration velocity monitoring\u003c\/li\u003e\n\u003cli\u003eEarly rotating equipment fault detection\u003c\/li\u003e\n\u003cli\u003eBearing degradation analysis support\u003c\/li\u003e\n\u003cli\u003eRotor imbalance identification\u003c\/li\u003e\n\u003cli\u003eMechanical looseness trend monitoring\u003c\/li\u003e\n\u003cli\u003ePredictive maintenance data acquisition\u003c\/li\u003e\n\u003cli\u003eAbnormal machinery resonance indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSuitable Equipment and Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eSteam turbine monitoring systems\u003c\/li\u003e\n\u003cli\u003eGas turbine protection systems\u003c\/li\u003e\n\u003cli\u003eCentrifugal compressor vibration analysis\u003c\/li\u003e\n\u003cli\u003eIndustrial blower monitoring\u003c\/li\u003e\n\u003cli\u003eRotating pump condition diagnostics\u003c\/li\u003e\n\u003cli\u003ePower generation equipment monitoring\u003c\/li\u003e\n\u003cli\u003ePetrochemical rotating machinery protection\u003c\/li\u003e\n\u003cli\u003eHeavy industrial vibration supervision systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003ePR9268\/202-000\u003c\/span\u003e\u003c\/strong\u003e delivers stable low-frequency vibration monitoring for critical rotating assets.\u003c\/p\u003e\n\n\u003cp\u003eThe electrodynamic sensing principle provides consistent long-term measurement reliability.\u003c\/p\u003e\n\n\u003cp\u003eIts armored cable structure improves mechanical protection in industrial installations.\u003c\/p\u003e\n\n\u003cp\u003eThe vertical sensing configuration supports accurate machinery vibration trend analysis.\u003c\/p\u003e\n\n\u003cp\u003eEngineering teams frequently deploy this sensor in turbine and compressor protection systems.\u003c\/p\u003e\n\n\u003cp\u003eThe robust enclosure design improves survivability in high-temperature process areas.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePackaging Information\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003ePR9268\/202-000\u003c\/span\u003e\u003c\/strong\u003e vibration transducer\u003c\/li\u003e\n\u003cli\u003e1 × Factory protective packaging\u003c\/li\u003e\n\u003cli\u003e1 × Product inspection documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal Shipping Service\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eFedEx international delivery available\u003c\/li\u003e\n\u003cli\u003eUPS industrial logistics supported\u003c\/li\u003e\n\u003cli\u003eDHL express shipping supported\u003c\/li\u003e\n\u003cli\u003eSecure export packaging included\u003c\/li\u003e\n\u003cli\u003eOrders commonly dispatch within 24-48 hours\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003e12-Month Warranty Policy\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e12-month warranty coverage included\u003c\/li\u003e\n\u003cli\u003eTechnical support during warranty period\u003c\/li\u003e\n\u003cli\u003eQuality verification before shipment\u003c\/li\u003e\n\u003cli\u003eProfessional industrial service assistance available\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProfessional FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy does this sensor use electrodynamic measurement technology?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eElectrodynamic sensing provides stable velocity measurement for rotating machinery diagnostics.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat installation mistake commonly affects measurement accuracy?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eFlexible or weak mounting brackets often introduce false vibration readings.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy should engineers avoid oversized measuring ranges?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eOversized ranges may reduce diagnostic sensitivity during low-amplitude vibration analysis.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow does the armored cable improve field reliability?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe armored structure protects signal wiring from mechanical damage and industrial wear.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhich application should prioritize this sensor selection?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eSelect this module for turbine, compressor, or pump systems requiring continuous vibration monitoring.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45142847750326,"sku":"PR9268\/202-000","price":214.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/PR9268-201-000_1_ad15b5ad-baee-48e2-8f59-dbea6716386f.jpg?v=1779783874","url":"https:\/\/www.plcsparehub.com\/products\/pr9268-202-000-epro-pr9268-series-vertical-velocity-transducer","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}