{"product_id":"pm861ak02-abb-redundant-ac-800m-controller-and-baseplate","title":"PM861AK02 ABB Redundant AC 800M Controller and Baseplate","description":"\u003ch3\u003e\u003cstrong\u003e\u003cmark\u003eABB PM861AK02\u003c\/mark\u003e | System 800xA AC 800M Controller Kit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cmark\u003eABB PM861AK02\u003c\/mark\u003e\u003c\/strong\u003e is a redundant CPU controller kit for ABB System 800xA automation systems. It belongs to the AC 800M controller family. The kit combines two PM861A CPU units with dedicated baseplates and communication accessories.\u003c\/p\u003e\n\u003cp\u003eEach CPU board contains a microprocessor, RAM, real-time clock, LED indicators, and a CompactFlash interface. The controller provides Ethernet and serial communication interfaces. Its architecture supports redundant CPU operation for higher system availability.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003ePM861AK02\u003c\/strong\u003e supports control applications through ABB Control Builder. Its modular architecture also supports distributed I\/O expansion and CEX-Bus communication.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Identification and Core Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cmark\u003ePM861AK02\u003c\/mark\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3BSE018160R1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eAC 800M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation Platform\u003c\/td\u003e\n\u003ctd\u003eSystem 800xA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRedundant CPU Controller Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003eMPC860\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock Frequency\u003c\/td\u003e\n\u003ctd\u003e48 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e16 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication RAM\u003c\/td\u003e\n\u003ctd\u003e7.155 MB available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware Storage\u003c\/td\u003e\n\u003ctd\u003e2 MB Flash PROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory Interface\u003c\/td\u003e\n\u003ctd\u003eCompactFlash interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoolean Operation Performance\u003c\/td\u003e\n\u003ctd\u003e1,000 operations in 0.23 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Cycle Time\u003c\/td\u003e\n\u003ctd\u003eDown to 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPU Redundancy\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Redundancy Switchover Time\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19.2–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical \/ Maximum Current\u003c\/td\u003e\n\u003ctd\u003e250 mA \/ 430 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical \/ Maximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e6.0 W \/ 10.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e196 × 119 × 135 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1,200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eCPU Architecture and Processing Capacity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePM861A\u003c\/strong\u003e CPU board handles controller processing and application execution. Its MPC860 processor operates at 48 MHz. The controller provides 16 MB of memory and 7.155 MB of application RAM.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessing Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eMPC860\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock Frequency\u003c\/td\u003e\n\u003ctd\u003e48 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e16 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication RAM\u003c\/td\u003e\n\u003ctd\u003e7.155 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware Flash PROM\u003c\/td\u003e\n\u003ctd\u003e2 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoolean Performance\u003c\/td\u003e\n\u003ctd\u003e0.23 ms per 1,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplications per Controller\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrograms per Application\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagrams per Application\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTasks per Controller\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDifferent Cycle Times\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Application Cycle Time\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese specifications help engineers evaluate processing capacity and application structure. Actual performance depends on application complexity and configured control tasks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Interfaces and Network Connectivity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe controller provides two RJ45 Ethernet ports and two RJ45 serial ports. These interfaces support Control Network communication and service-tool connections.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN1 \/ CN2\u003c\/td\u003e\n\u003ctd\u003eTwo Ethernet ports, RJ45, 10 Mbit\/s\u003c\/td\u003e\n\u003ctd\u003eControl Network connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Standard\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3\u003c\/td\u003e\n\u003ctd\u003eIndustrial Ethernet communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Network Protocols\u003c\/td\u003e\n\u003ctd\u003eMMS and IAC\u003c\/td\u003e\n\u003ctd\u003eController communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM3\u003c\/td\u003e\n\u003ctd\u003eRS-232C, 75–19,200 baud\u003c\/td\u003e\n\u003ctd\u003eGeneral serial communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM3 Isolation\u003c\/td\u003e\n\u003ctd\u003eNot optically isolated\u003c\/td\u003e\n\u003ctd\u003eIncludes modem control signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM4\u003c\/td\u003e\n\u003ctd\u003eRS-232C, 9,600 baud\u003c\/td\u003e\n\u003ctd\u003eConfiguration tool connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM4 Isolation\u003c\/td\u003e\n\u003ctd\u003eOptically isolated\u003c\/td\u003e\n\u003ctd\u003eService and configuration access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork integration considerations:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnect CN1 and CN2 to the designated Control Network infrastructure.\u003c\/li\u003e\n\u003cli\u003eUse switched Ethernet for the recommended 100 Mbit\/s network backbone.\u003c\/li\u003e\n\u003cli\u003eCheck the configured network topology before enabling redundant communication.\u003c\/li\u003e\n\u003cli\u003eUse COM4 for the supported configuration-tool connection.\u003c\/li\u003e\n\u003cli\u003eCheck COM3 modem-control requirements before connecting external serial equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe two Ethernet ports provide built-in network connectivity. Confirm the complete redundancy configuration before treating both network paths as independent redundant channels.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCPU Redundancy and System Availability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePM861AK02\u003c\/strong\u003e supports CPU redundancy in compatible AC 800M configurations. The redundant architecture covers CPU operation, CEX-Bus, communication interfaces, and S800 I\/O.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPU redundancy:\u003c\/strong\u003e Supports controller-level availability through a redundant CPU arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitchover performance:\u003c\/strong\u003e Maximum specified switchover time is 10 ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCEX-Bus:\u003c\/strong\u003e Supports up to 12 communication modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCEX-Bus current:\u003c\/strong\u003e Maximum supply current is 2.4 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower monitoring:\u003c\/strong\u003e Includes a redundant power supply status input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory backup:\u003c\/strong\u003e Uses a built-in 3.6 V lithium battery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRedundant configurations require compatible hardware and correct system engineering. Check the applicable ABB redundancy guidelines before installation or expansion.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eS800 I\/O and ModuleBus Expansion\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe controller connects to S800 I\/O through the ModuleBus architecture. Supported cluster capacity depends on the CPU configuration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSingle CPU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundant CPU\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical I\/O Clusters\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical I\/O Clusters\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum I\/O Modules\u003c\/td\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003ctd\u003e84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAdditional ModuleBus specifications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModuleBus scan rate:\u003c\/strong\u003e 0–100 ms, depending on I\/O module quantity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 V supply current:\u003c\/strong\u003e Maximum 1.0 A on the electrical ModuleBus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5 V supply current:\u003c\/strong\u003e Maximum 1.5 A on the electrical ModuleBus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModuleBus termination:\u003c\/strong\u003e The package includes two TB807 terminators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck I\/O module quantity, cluster type, and power loading during system expansion. Redundant configurations have a different maximum I\/O capacity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply and Electrical Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e19.2–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Current\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current\u003c\/td\u003e\n\u003ctd\u003e430 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e6.0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e10.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant Supply Status Input\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Isolation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V, as listed in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eVerify supply polarity and voltage before energizing the controller. Use the approved system power arrangement. The listed dielectric test value requires confirmation against the applicable ABB datasheet before test planning.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Conditions and EMC Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e+5 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Change\u003c\/td\u003e\n\u003ctd\u003e3 °C\/min, IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Installation Altitude\u003c\/td\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003eDegree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eG3, ISA 71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5–95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcoustic Noise\u003c\/td\u003e\n\u003ctd\u003eBelow 55 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20, EN 60529 \/ IEC 529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmission Standard\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmunity Standard\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eVibration data supplied for the controller:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e10–50 Hz: 0.0375 mm amplitude.\u003c\/li\u003e\n\u003cli\u003e50–150 Hz: 0.5 g acceleration.\u003c\/li\u003e\n\u003cli\u003e5–500 Hz: 0.2 g acceleration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe supplied vibration ranges overlap and require verification against the original ABB documentation. Confirm the correct test profile before applying vibration qualification criteria.\u003c\/p\u003e\n\u003cp\u003eThe controller supports industrial environmental conditions. Its EMC specifications address both emissions and immunity. Maintain proper grounding, cable separation, and cabinet installation practices.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification or Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSupplied Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Marking\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Emission\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Immunity\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eEN 50178, IEC 61131-2, UL 508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location\u003c\/td\u003e\n\u003ctd\u003eUL 60079-15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certificates\u003c\/td\u003e\n\u003ctd\u003eABS, BV, DNV-GL, LR, RS, CCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Classification\u003c\/td\u003e\n\u003ctd\u003eIndustrial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTÜV Approval\u003c\/td\u003e\n\u003ctd\u003eNot listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE\u003c\/td\u003e\n\u003ctd\u003eDirective 2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe supplied marine certification information covers PM861AK01 and PM861AK02. Confirm the exact certificate scope and hardware revision for the intended installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e196 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e119 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e135 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1,200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseplate Model\u003c\/td\u003e\n\u003ctd\u003eTP830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTP830 Baseplate Width\u003c\/td\u003e\n\u003ctd\u003e115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eDIN rail, slide-and-lock mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCheck the cabinet layout before installation. Allow sufficient space for connectors, cables, and maintenance access.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents | PM861AK02 Controller Kit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003ePM861A\u003c\/td\u003e\n\u003ctd\u003eCPU controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eTP830\u003c\/td\u003e\n\u003ctd\u003eBaseplate, 115 mm width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eTB807\u003c\/td\u003e\n\u003ctd\u003eModuleBus terminator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eTK850\u003c\/td\u003e\n\u003ctd\u003eCEX-Bus expansion cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eTB851\u003c\/td\u003e\n\u003ctd\u003eRCU-Link cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e4943013-6\u003c\/td\u003e\n\u003ctd\u003e3.6 V lithium backup battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe listed package provides hardware for a redundant controller arrangement. Confirm the supplied accessories and quantities against the purchase quotation.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68105130508470,"sku":"PM861AK02","price":369.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/PM861AK02-1.jpg?v=1795074451","url":"https:\/\/www.plcsparehub.com\/products\/pm861ak02-abb-redundant-ac-800m-controller-and-baseplate","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}