{"product_id":"pm856k01-abb-ac-800m-processor-kit-pm856-tp830-fast-shipping","title":"PM856K01 ABB AC 800M Processor Kit PM856 TP830 | Fast Shipping","description":"\u003ch3\u003e\u003cstrong\u003eABB PM856K01 AC 800M Processor Module Kit Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB PM856K01\u003c\/strong\u003e package delivers reliable processing power for demanding industrial automation applications.\u003c\/p\u003e\n\u003cp\u003eThis processor kit belongs to the world-renowned \u003cstrong\u003eABB AC 800M\u003c\/strong\u003e control family.\u003c\/p\u003e\n\u003cp\u003eIt integrates a high-performance \u003cstrong\u003eMPC860\u003c\/strong\u003e microprocessor running at a clock frequency of 48 MHz.\u003c\/p\u003e\n\u003cp\u003eEngineers utilize the \u003cstrong\u003ePM856K01\u003c\/strong\u003e to execute complex control loops and manage local S800 I\/O clusters efficiently.\u003c\/p\u003e\n\u003cp\u003eThe kit features the core \u003cstrong\u003ePM856\u003c\/strong\u003e processor unit paired with the matching \u003cstrong\u003eTP830\u003c\/strong\u003e baseplate assembly.\u003c\/p\u003e\n\u003cp\u003eIntegrated dual Ethernet ports enable smooth plant-wide networking within the ABB System 800xA architecture.\u003c\/p\u003e\n\u003cp\u003eOnboard serial ports provide direct connections for field modems and diagnostics service tools.\u003c\/p\u003e\n\u003cp\u003eThe rugged housing ensures stable processing under continuous industrial operating conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eABB\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePM856K01\u003c\/strong\u003e (Kit includes \u003cstrong\u003ePM856\u003c\/strong\u003e CPU \u0026amp; \u003cstrong\u003eTP830\u003c\/strong\u003e Baseplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ac-800m\"\u003e\u003cstrong\u003eABB AC 800M\u003c\/strong\u003e\u003c\/a\u003e Controller Hardware Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor \u0026amp; Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eMPC860\u003c\/strong\u003e @ 48 MHz, 8 MB SDRAM, 2 MB Flash PROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Input \u0026amp; Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (19.2 to 30 VDC), 180 mA typical current (300 mA max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 W typical base CPU (10 W typical with full ModuleBus and CEX-Bus load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Reservoir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 ms internal power hold-up for controlled processor shut down\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModuleBus Expansion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect electrical connection for 12 x S800 I\/O units; optical extension up to 7 clusters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCEX-Bus Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports up to 12 communication interface modules (24V, 2.4A supply output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Ports (CN1\/CN2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual RJ45 10Base-T (10 Mbit\/s half duplex), IEEE 802.3 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Ports (COM3\/COM4)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOM3 (RS-232C modem support, up to 19200 baud); COM4 (RS-232C service tool, 9600 baud)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to +55°C (32°F to 131°F) standard operating envelope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C (-40°F to 158°F) transport and storage limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity \u0026amp; Environmental Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing relative humidity, G3 harsh environment rating compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise Suppression \u0026amp; Interference Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-2 immunity standards for heavy industrial electromagnetic environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution \u0026amp; Scan Rate Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSub-millisecond task execution latency; high-precision process variable scanning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Protection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 protection classification according to EN60529 \/ IEC 529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions \u0026amp; Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eW 119 x H 186 x D 135 mm (4.7 x 7.3 x 5.3 in.), Weight: 1100 g (2.4 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Backup\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.6V 950mAh 1\/2 AA Lithium internal (48 hours min); optional SB821\/SB822 external units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Architecture \u0026amp; Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eProcessor Core Architecture\u003c\/strong\u003e\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eMotorola \u003cstrong\u003eMPC860\u003c\/strong\u003e 32-bit RISC processor operating at 48 MHz clock speed.\u003c\/li\u003e\n\u003cli\u003eDedicated 2 MB Flash PROM reserved strictly for system firmware execution.\u003c\/li\u003e\n\u003cli\u003eHigh-speed 8 MB SDRAM handling dynamic application program memory storage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\u003cstrong\u003eNetworking and Serial Communication Protocols\u003c\/strong\u003e\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eDual RJ45 10Base-T Ethernet ports \u003cstrong\u003eCN1\u003c\/strong\u003e and \u003cstrong\u003eCN2\u003c\/strong\u003e for redundant control network loops.\u003c\/li\u003e\n\u003cli\u003eRS-232C serial channel \u003cstrong\u003eCOM3\u003c\/strong\u003e with modem controls and configurable baud rates up to 19,200 bps.\u003c\/li\u003e\n\u003cli\u003eDedicated RS-232C serial interface \u003cstrong\u003eCOM4\u003c\/strong\u003e fixed at 9,600 baud for local engineering software tools.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\u003cstrong\u003eI\/O and Peripheral Bus Expansion\u003c\/strong\u003e\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical ModuleBus drives 1 x local cluster housing up to 12 x S800 I\/O modules directly.\u003c\/li\u003e\n\u003cli\u003eOptional Optical ModuleBus expansion extends control to 7 remote clusters with 84 total I\/O units.\u003c\/li\u003e\n\u003cli\u003eSide-mounted CEX-Bus interface accommodates up to 12 specialized fieldbus interface cards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Setup Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eMount the \u003cstrong\u003eTP830\u003c\/strong\u003e baseplate securely onto a standard 35 mm DIN-rail prior to inserting the processor.\u003c\/p\u003e\n\u003cp\u003eConnect the 24 VDC primary power supply leads to terminals \u003cstrong\u003eL+\u003c\/strong\u003e and \u003cstrong\u003eL-\u003c\/strong\u003e on the four-pin screw connector.\u003c\/p\u003e\n\u003cp\u003eWire dual power monitoring signals to terminals \u003cstrong\u003eSA\u003c\/strong\u003e and \u003cstrong\u003eSB\u003c\/strong\u003e for real-time power supply status tracking.\u003c\/p\u003e\n\u003cp\u003eEnsure the DIN-rail grounding clip makes solid physical contact with an earthed cabinet mounting panel.\u003c\/p\u003e\n\u003cp\u003eSnap the \u003cstrong\u003ePM856\u003c\/strong\u003e module firmly onto the \u003cstrong\u003eTP830\u003c\/strong\u003e baseplate until locking mechanisms engage completely.\u003c\/p\u003e\n\u003cp\u003ePlug pre-terminated RJ45 Ethernet lines into ports \u003cstrong\u003eCN1\u003c\/strong\u003e and \u003cstrong\u003eCN2\u003c\/strong\u003e for system network integration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDebugging \u0026amp; Maintenance Best Practices\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInspect front-panel diagnostic light indicators during initial power-up sequences to verify operational status.\u003c\/p\u003e\n\u003cp\u003eMonitor status inputs \u003cstrong\u003eSA\u003c\/strong\u003e and \u003cstrong\u003eSB\u003c\/strong\u003e to isolate external power supply faults before resetting CPU parameters.\u003c\/p\u003e\n\u003cp\u003eReplace the internal 3.6 V lithium backup battery while keeping 24 VDC external power actively applied.\u003c\/p\u003e\n\u003cp\u003eMaintaining external power during battery replacement prevents RAM memory loss and software corruption.\u003c\/p\u003e\n\u003cp\u003eRecharge depleted external battery units fully within 7 hours to guarantee system data retention capability.\u003c\/p\u003e\n\u003cp\u003eClean dust accumulation from side ventilation slots using low-pressure dry air during scheduled maintenance outages.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility \u0026amp; Certifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFully compatible with \u003cstrong\u003eABB System 800xA\u003c\/strong\u003e engineering software toolsets and Compact Control Builder software.\u003c\/p\u003e\n\u003cp\u003eSeamlessly integrates with all S800 I\/O modules operating on electrical or optical ModuleBus networks.\u003c\/p\u003e\n\u003cp\u003eInteroperates with standard CEX-Bus communication cards including PROFIBUS DP, ModuleBus, and serial interfaces.\u003c\/p\u003e\n\u003cp\u003eCertified for CE mark compliance and industrial electro-magnetic compatibility standard EN 61000-6-2.\u003c\/p\u003e\n\u003cp\u003eUL listed and CSA certified for installation in standard industrial automation control enclosures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eMonitors distributed continuous control loops in chemical processing plants and oil refining facilities.\u003c\/p\u003e\n\u003cp\u003eExecutes fast machine automation sequences in automotive manufacturing lines and material handling installations.\u003c\/p\u003e\n\u003cp\u003eManages turbomachinery safety monitoring and power generation auxiliary systems inside utility stations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List, Dispatch \u0026amp; Warranty Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e1 x ABB PM856 Processor Module\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1 x ABB TP830 Baseplate Assembly\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1 x Bus Termination Set\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpress Global Logistics:\u003c\/strong\u003e Fast dispatch within 24 to 48 hours via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, or \u003cstrong\u003eDHL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Protection:\u003c\/strong\u003e Includes a comprehensive \u003cstrong\u003e12-Month Warranty\u003c\/strong\u003e coverage plan.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOur automation engineering team frequently sees the \u003cstrong\u003eABB PM856K01\u003c\/strong\u003e deployed in critical infrastructure applications.\u003c\/p\u003e\n\u003cp\u003eField experience shows that power input fluctuations cause common diagnostic alarms on older control panels.\u003c\/p\u003e\n\u003cp\u003eIn a recent plant upgrade, an operator experienced unexplained CPU shut-down warnings on an \u003cstrong\u003eAC 800M\u003c\/strong\u003e rack.\u003c\/p\u003e\n\u003cp\u003eOur technical team traced the issue to voltage drops on terminals \u003cstrong\u003eSA\u003c\/strong\u003e and \u003cstrong\u003eSB\u003c\/strong\u003e below the 15 V logical high threshold.\u003c\/p\u003e\n\u003cp\u003eRebalancing the 24 VDC power supply immediately restored full stability without replacing the \u003cstrong\u003ePM856\u003c\/strong\u003e processor module.\u003c\/p\u003e\n\u003cp\u003eWe recommend installing an external \u003cstrong\u003eSB821\u003c\/strong\u003e or \u003cstrong\u003eSB822\u003c\/strong\u003e battery module for facilities subject to extended seasonal shutdowns.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSelection \u0026amp; Purchasing Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSelect the \u003cstrong\u003ePM856K01\u003c\/strong\u003e when your automation topology requires moderate I\/O counts and direct \u003cstrong\u003eAC 800M\u003c\/strong\u003e execution.\u003c\/p\u003e\n\u003cp\u003eVerify whether your site application requires electrical ModuleBus or optical fiber connections across remote control panels.\u003c\/p\u003e\n\u003cp\u003eConfirm the quantity of additional CEX-Bus communication interfaces needed for third-party serial or fieldbus integration.\u003c\/p\u003e\n\u003cp\u003eContact our technical support specialists today to confirm exact module firmware versions for your target system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e What components make up the complete \u003cstrong\u003ePM856K01\u003c\/strong\u003e processor kit?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e The kit includes the core \u003cstrong\u003ePM856\u003c\/strong\u003e processor module, the \u003cstrong\u003eTP830\u003c\/strong\u003e baseplate, and the required bus termination units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e How long does the internal lithium battery retain program data in memory without main power?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e The internal 3.6V 1\/2 AA lithium battery maintains memory contents for a minimum of 48 hours without primary supply power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e Can I expand the battery retention time for longer plant maintenance shutdowns?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Yes, connecting an optional \u003cstrong\u003eSB821\u003c\/strong\u003e or \u003cstrong\u003eSB822\u003c\/strong\u003e external battery module extends memory backup time up to 1 month or 100 hours respectively.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e What do the power supply status inputs \u003cstrong\u003eSA\u003c\/strong\u003e and \u003cstrong\u003eSB\u003c\/strong\u003e do on the power connector?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Inputs \u003cstrong\u003eSA\u003c\/strong\u003e and \u003cstrong\u003eSB\u003c\/strong\u003e monitor dual redundant power supply status, treating signals above 15 VDC as logical high conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e How fast will my \u003cstrong\u003ePM856K01\u003c\/strong\u003e order ship after payment confirmation?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Orders are processed rapidly and dispatched within 24 to 48 hours using premium \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, or \u003cstrong\u003eDHL\u003c\/strong\u003e express delivery services.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":67607817191606,"sku":"PM856K01","price":158.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/PM858K02_3e7c29c1-8944-4027-b72c-38f813be0d87.jpg?v=1791526859","url":"https:\/\/www.plcsparehub.com\/products\/pm856k01-abb-ac-800m-processor-kit-pm856-tp830-fast-shipping","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}