{"product_id":"pfea111-65-abb-pressductor-load-cell-signal-controller","title":"PFEA111-65 ABB Pressductor Load Cell Signal Controller","description":"\u003ch3\u003e\u003cstrong\u003e\u003cmark\u003eABB PFEA111-65\u003c\/mark\u003e | Pressductor Compact Tension Measurement Unit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cmark\u003eABB PFEA111-65\u003c\/mark\u003e\u003c\/strong\u003e is a compact tension measurement unit for ABB Pressductor load cells. It processes load cell signals and provides analog outputs for tension control systems. Its dual-channel input architecture supports two load cell signal channels.\u003c\/p\u003e\n\u003cp\u003eThe unit provides voltage and current output options. Engineers can adjust the signal filter to match process response requirements. The \u003cstrong\u003ePFEA111\u003c\/strong\u003e is the basic analog version in the Pressductor tension electronics range. It does not include PROFIBUS-DP communication.\u003c\/p\u003e\n\u003cp\u003eOrder code: \u003cstrong\u003e3BSE050090R65\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Identification and Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePFEA111-65\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Code\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3BSE050090R65\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eABB Pressductor Tension Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCompact Tension Measurement Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Cell Inputs\u003c\/td\u003e\n\u003ctd\u003e2 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Cell Excitation\u003c\/td\u003e\n\u003ctd\u003e330 Hz, 0.5 A RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Voltage Output\u003c\/td\u003e\n\u003ctd\u003e±0 to +10 V, adjustable filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Current Output\u003c\/td\u003e\n\u003ctd\u003e4–20 mA, maximum load 550 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Cut-off\u003c\/td\u003e\n\u003ctd\u003eAdjustable from 0.25 Hz to 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e≤10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% full scale + 0.1% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003eLess than 1 least significant bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon-Mode Suppression\u003c\/td\u003e\n\u003ctd\u003eGreater than 70 dB at DC and 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCross-Channel Suppression\u003c\/td\u003e\n\u003ctd\u003eGreater than 80 dB from DC to 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC nominal, 18–36 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e+5 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail, EN 50022-35×7.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.3 kg, distributor-reported net weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eLoad Cell Input and Signal Processing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePFEA111-65\u003c\/strong\u003e accepts signals from two Pressductor load cell channels. Its excitation circuit operates at 330 Hz and 0.5 A RMS. This arrangement supports the connected load cell measurement system.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput channels:\u003c\/strong\u003e Two load cell signal inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExcitation frequency:\u003c\/strong\u003e 330 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExcitation current:\u003c\/strong\u003e 0.5 A RMS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal processing:\u003c\/strong\u003e Adjustable filtering for process signal conditioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e 10 ms maximum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe supplied specifications do not define a numerical tension measurement range. Confirm the connected load cell rating and system scaling before commissioning. Do not interpret the output voltage range as the load cell's mechanical measurement range.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAnalog Outputs and Filter Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe unit provides voltage and current signal output options. These outputs support connection to compatible control and monitoring equipment.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegration Notes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output\u003c\/td\u003e\n\u003ctd\u003e±0 to +10 V\u003c\/td\u003e\n\u003ctd\u003eAdjustable filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Output\u003c\/td\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003ctd\u003eMaximum load 550 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Cut-off\u003c\/td\u003e\n\u003ctd\u003e0.25 Hz to 1 kHz\u003c\/td\u003e\n\u003ctd\u003eAdjust according to process dynamics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e≤10 ms\u003c\/td\u003e\n\u003ctd\u003eConsider during control-loop tuning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eChoose the output type according to the receiving controller's input specification. Check the current-loop load before connecting the 4–20 mA output. Set the filter cut-off to balance signal stability and response speed.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMeasurement Accuracy and Signal Immunity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB PFEA111-65\u003c\/strong\u003e provides defined accuracy and signal rejection specifications. These characteristics support stable tension feedback in industrial applications.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% full scale + 0.1% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003eLess than 1 least significant bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon-Mode Suppression at DC\u003c\/td\u003e\n\u003ctd\u003eGreater than 70 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon-Mode Suppression at 60 Hz\u003c\/td\u003e\n\u003ctd\u003eGreater than 70 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCross-Channel Suppression\u003c\/td\u003e\n\u003ctd\u003eGreater than 80 dB from DC to 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe supplied datasheet does not specify a separate sensitivity or measurement resolution value. Linearity is expressed in least significant bits. Do not convert this figure into an absolute resolution without the applicable conversion details.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Supply and Environmental Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermitted Supply Range\u003c\/td\u003e\n\u003ctd\u003e18–36 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e+5 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eInstall the unit in a suitable industrial control cabinet. IP20 protection does not provide protection against water ingress. Maintain suitable cabinet ventilation and environmental control.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68105240740022,"sku":"PFEA111-65","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/PFEA111-65-1.jpg?v=1795075360","url":"https:\/\/www.plcsparehub.com\/products\/pfea111-65-abb-pressductor-load-cell-signal-controller","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}