{"product_id":"pfea111-20-abb-pfea111-series-tension-measurement-electronics","title":"PFEA111-20 ABB PFEA111 Series Tension Measurement Electronics","description":"\u003ch3\u003e\u003cstrong\u003eABB PFEA111-20 Tension Electronics – Dual-Channel Measurement and Signal Processing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB PFEA111-20\u003c\/strong\u003e is tension electronics designed for industrial web tension measurement systems. It processes signals from two load cells and provides voltage and current outputs for downstream control equipment.\u003c\/p\u003e\n\u003cp\u003eThe unit supports separate channel readings and calculated values. Operators can view \u003cstrong\u003eA, B, A+B, and A-B\u003c\/strong\u003e on the display. This allows the control system to monitor individual load cell signals and combined tension values.\u003c\/p\u003e\n\u003cp\u003eAdjustable output filtering helps reduce signal fluctuations caused by mechanical vibration or process disturbances. The voltage and current outputs can be configured for different tension ranges and response requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Measurement Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe PFEA111-20 operates as a signal-processing interface between load cells and the plant control system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSignal processing path:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput A:\u003c\/strong\u003e Receives the signal from the first load cell.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput B:\u003c\/strong\u003e Receives the signal from the second load cell.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal calculation:\u003c\/strong\u003e Provides A, B, A+B, and A-B display values.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput stage:\u003c\/strong\u003e Delivers voltage and current signals to external control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiltering:\u003c\/strong\u003e Provides adjustable filtering for both analog output channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis arrangement is useful when two load cells monitor tension across a roll or web-handling process. The separate readings also help technicians identify differences between the two measurement points.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Electrical and Measurement Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct model\u003c\/td\u003e\n\u003ctd\u003ePFEA111-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eABB Product ID\u003c\/td\u003e\n\u003ctd\u003e3BSE050090R20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eTension Electronics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of load cell inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd\u003e10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad cell excitation\u003c\/td\u003e\n\u003ctd\u003e0.5 A RMS, 330 Hz, regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay values\u003c\/td\u003e\n\u003ctd\u003eA, B, A+B, A-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage output\u003c\/td\u003e\n\u003ctd\u003e0–10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage output range\u003c\/td\u003e\n\u003ctd\u003e-5 to +11 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage output load\u003c\/td\u003e\n\u003ctd\u003e5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage output ripple\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 mV p-p at wrap gain = 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent output\u003c\/td\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent output range\u003c\/td\u003e\n\u003ctd\u003e0–21 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current output load\u003c\/td\u003e\n\u003ctd\u003e550 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault output response time\u003c\/td\u003e\n\u003ctd\u003e15 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard output bandwidth\u003c\/td\u003e\n\u003ctd\u003e35 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWrap gain adjustment\u003c\/td\u003e\n\u003ctd\u003e0.5–20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Adjustable Filtering and Dynamic Response\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe PFEA111-20 provides additional filtering for voltage and current outputs. The filter setting affects how quickly the output follows changes in measured tension.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilter Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCut-off Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30 ms\u003c\/td\u003e\n\u003ctd\u003e15 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e75 ms\u003c\/td\u003e\n\u003ctd\u003e5 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 ms\u003c\/td\u003e\n\u003ctd\u003e1.5 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e750 ms\u003c\/td\u003e\n\u003ctd\u003e0.5 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1500 ms\u003c\/td\u003e\n\u003ctd\u003e0.25 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePractical commissioning considerations:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse a faster filter when the process requires rapid tension response.\u003c\/li\u003e\n\u003cli\u003eUse a slower filter when mechanical vibration causes unstable analog readings.\u003c\/li\u003e\n\u003cli\u003eCheck the response at both outputs after changing the filter setting.\u003c\/li\u003e\n\u003cli\u003eVerify that the selected filter does not delay important tension corrections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA longer filtering time can stabilize the displayed and transmitted values. However, excessive filtering may delay the control system's response to sudden tension changes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Load Cell Excitation and Measurement Range\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe electronics provide regulated excitation for two compatible load cells. The specified maximum load includes two load cells, cable resistance up to 5 Ω, and cable capacitance up to 1 μF.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible load cell types listed in the technical information:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePFCL 301E\u003c\/li\u003e\n\u003cli\u003ePFTL 301E\u003c\/li\u003e\n\u003cli\u003ePFRL 101\u003c\/li\u003e\n\u003cli\u003ePFTL 101\u003c\/li\u003e\n\u003cli\u003ePFCL 201\u003c\/li\u003e\n\u003cli\u003ePFTL 201\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement range reference:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero setting range\u003c\/td\u003e\n\u003ctd\u003e±2.0 × F_nom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic measurement range, including zero setting\u003c\/td\u003e\n\u003ctd\u003e-2.5 × F_nom to +3.5 × F_nom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eF_nom\u003c\/strong\u003e represents the nominal load of the connected load cell. The actual measurement range depends on the selected load cell rating and system configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Power Supply and Installation Versions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe supplied technical information describes two enclosure configurations. Their power requirements and protection ratings differ.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20 Version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP65 Version\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003ctd\u003eWall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 V DC supply\u003c\/td\u003e\n\u003ctd\u003e18–36 V DC\u003c\/td\u003e\n\u003ctd\u003e18–36 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC supply\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003ctd\u003e85–264 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse protection\u003c\/td\u003e\n\u003ctd\u003eAutomatic reset\u003c\/td\u003e\n\u003ctd\u003eSlow-blow, 2 A, 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e86 × 136 × 58 mm\u003c\/td\u003e\n\u003ctd\u003e120 × 180 × 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed version weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003ctd\u003e1.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor the AC supply version, the specified mains frequency is 45–65 Hz. The listed input current is 0.2–0.1 A across the 100–240 V AC range.\u003c\/p\u003e\n\u003cp\u003eThe stated power consumption is 8 W at 24 V DC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation note:\u003c\/strong\u003e Confirm the enclosure version before selecting the power supply, mounting location, and cabinet cut-out. Do not assume that every PFEA111-20 order uses the same enclosure configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Configuration Parameters and Output Scaling\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe supplied PFEA111 default configuration provides a useful reference for commissioning. Actual settings must match the installed load cells and mechanical arrangement.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSetting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefault Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay language\u003c\/td\u003e\n\u003ctd\u003eEnglish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay unit\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDecimal places\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad cells per roll\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eObject type\u003c\/td\u003e\n\u003ctd\u003eStandard roll\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad cell nominal load\u003c\/td\u003e\n\u003ctd\u003e1.0 kN \/ 225 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWrap gain\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent output filter\u003c\/td\u003e\n\u003ctd\u003e250 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent output low tension\u003c\/td\u003e\n\u003ctd\u003e0 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent output high tension\u003c\/td\u003e\n\u003ctd\u003e2000 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent output low value\u003c\/td\u003e\n\u003ctd\u003e4.00 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent output high value\u003c\/td\u003e\n\u003ctd\u003e20.00 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent output limits\u003c\/td\u003e\n\u003ctd\u003e0–21 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage output filter\u003c\/td\u003e\n\u003ctd\u003e250 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage output low tension\u003c\/td\u003e\n\u003ctd\u003e0 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage output high tension\u003c\/td\u003e\n\u003ctd\u003e2000 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage output low value\u003c\/td\u003e\n\u003ctd\u003e0.00 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage output high value\u003c\/td\u003e\n\u003ctd\u003e+10.00 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage output limits\u003c\/td\u003e\n\u003ctd\u003e-5 to +11 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWhen integrating the unit with a PLC or DCS, verify the configured tension span and output scaling at both ends of the measurement range. A mismatch between the electronics and controller scaling can produce incorrect engineering values even when the analog signal is electrically stable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Environmental and Mechanical Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e+5 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage \/ non-operating temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero point temperature drift\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;50 ppm\/K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity temperature drift\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;75 ppm\/K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP20 version protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP65 version protection\u003c\/td\u003e\n\u003ctd\u003eIP65, NEMA 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe operating temperature specification applies to the outside of the IP20 and IP65 units. Check the actual cabinet environment and ventilation conditions before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Field Commissioning Checks\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the hardware version.\u003c\/strong\u003e Confirm the product identification, enclosure type, and supply voltage before wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck load cell compatibility.\u003c\/strong\u003e Confirm the sensor model, nominal load, excitation requirements, and cable characteristics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect both input channels.\u003c\/strong\u003e Compare A and B readings under a known mechanical load. Investigate unexpected differences before calibrating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm output scaling.\u003c\/strong\u003e Check the configured low and high tension values against the PLC or DCS engineering range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest filtering behavior.\u003c\/strong\u003e Apply a controlled tension change and observe the output response. Select a filter setting that balances stability and response time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify zero and span.\u003c\/strong\u003e Perform zero adjustment and calibration using the approved procedure for the installed system.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor an unstable tension reading, compare the individual A and B values before changing the filter. If both channels fluctuate together, inspect mechanical vibration, excitation, grounding, and cable routing. If only one channel fluctuates, investigate its load cell and wiring first.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Product Identification and Ordering Details\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInformation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePFEA111-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSE050090R20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct family\u003c\/td\u003e\n\u003ctd\u003ePFEA111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct description\u003c\/td\u003e\n\u003ctd\u003eTension Electronics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms tariff number\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum order quantity\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder multiple\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed gross weight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed net weight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrevious product ID\u003c\/td\u003e\n\u003ctd\u003e3BSE028140R20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering note:\u003c\/strong\u003e The listed 0.2 kg weight is the commercial product record value. It should not be confused with the separately specified IP20 and IP65 enclosure weights.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Professional FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What should technicians check if the A and B readings differ significantly under the same mechanical condition?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirst, check load cell mounting, roller alignment, cable connections, and mechanical load distribution. Then compare the two channels under a controlled load. Do not correct the difference through output scaling before confirming the mechanical installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can the PFEA111-20 directly replace another PFEA111 unit without recalibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot automatically. Confirm the complete product ID, hardware version, enclosure, load cell rating, and stored configuration. Even when the replacement has matching hardware, verify zero, span, output scaling, and filter settings during commissioning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Why might the PLC display a different tension value from the PFEA111-20 front panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCommon causes include different engineering ranges, incorrect analog input scaling, signal wiring errors, and mismatched output assignments. Measure the actual voltage or current at the controller input. Compare that value with the PFEA111-20 output configuration before changing calibration settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What is the practical difference between using A+B and A-B during troubleshooting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA+B represents the combined channel reading, while A-B shows the difference between the two channels. The combined value helps assess overall tension. The difference value can help identify uneven loading, sensor imbalance, or mechanical alignment problems. Interpret both values according to the configured measurement arrangement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What information should be checked before ordering a replacement for an installed unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecord the complete ABB product ID, enclosure protection rating, supply voltage, terminal arrangement, load cell models, and application settings. Also confirm whether the existing system uses separate analog outputs for voltage and current. These checks reduce the risk of ordering a unit with an incompatible installation configuration.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68158594547894,"sku":"PFEA111-20","price":203.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/PFEA111-20-3.jpg?v=1795595405","url":"https:\/\/www.plcsparehub.com\/products\/pfea111-20-abb-pfea111-series-tension-measurement-electronics","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}