{"product_id":"pepperl-fuchs-kfd2-st2-ex2-isolated-namur-input-amplifier-module","title":"Pepperl+Fuchs KFD2-ST2-EX2 Isolated NAMUR Input Amplifier Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0066cc;\"\u003ePepperl+Fuchs KFD2-ST2-EX2\u003c\/span\u003e\u003c\/strong\u003e is a \u003cstrong\u003e2-channel isolated switch amplifier\u003c\/strong\u003e for industrial signal conditioning and hazardous-area applications.\u003c\/p\u003e\n\u003cp\u003eThis interface accepts dry contact or NAMUR sensor signals from field devices. It converts input states into active transistor outputs for control systems.\u003c\/p\u003e\n\u003cp\u003eThe module provides \u003cstrong\u003eLine Fault Detection (LFD)\u003c\/strong\u003e for input circuit monitoring. Engineers can configure reversible operating modes through front-mounted DIP switches.\u003c\/p\u003e\n\u003cp\u003eIts reinforced galvanic isolation protects signal circuits from electrical interference. The module also supports \u003cstrong\u003eSIL 2 applications\u003c\/strong\u003e under IEC\/EN 61508.\u003c\/p\u003e\n\u003cp\u003eThe KFD2-ST2-EX2 supports Power Rail or direct terminal power connections. Its compact B2 housing fits standard 35 mm DIN mounting rails.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eKFD2-ST2-EX2\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e181000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK-System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-Channel Switch Amplifier \/ Isolated Barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry Contact and NAMUR Sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo Active Electronic Transistor Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Fault Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Circuit Breakage and Short-Circuit Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront-Mounted DIP Switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e1. Power Supply and Electrical Input\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Rail or Terminals 14+, 15-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Input Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1+, 2+, 3- \/ 4+, 5+, 6-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAMUR Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 60947-5-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen-Circuit Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2–2.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Hysteresis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e2. Output and Signal Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput I Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal 7+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput II Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal 9+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eActive Electronic Transistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic 1 Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(L+) - 3.5 V at 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic 0 Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff-State Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 10 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShort-Circuit Protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Switching Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCollective Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e3. Galvanic Isolation and Safety Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput \/ Output:\u003c\/strong\u003e Reinforced insulation according to IEC 62103.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput \/ Power Supply:\u003c\/strong\u003e Reinforced insulation according to IEC 62103.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage:\u003c\/strong\u003e 300 Vrms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput \/ Input:\u003c\/strong\u003e No galvanic isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput \/ Output:\u003c\/strong\u003e No galvanic isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput \/ Power Supply:\u003c\/strong\u003e No galvanic isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Pole:\u003c\/strong\u003e Terminal 14+.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Note:\u003c\/strong\u003e The input channels share a common electrical reference. Both outputs also share a common pole. Do not treat these channels as independently isolated circuits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e4. Hazardous-Area Parameters and Certifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEU-Type Examination Certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePTB 00 ATEX 2035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX Gas Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII (1) G [Ex ia] IIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX Dust Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII (1) D [Ex ia] IIIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEx ia IIC \/ Ex ia IIIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output Voltage Uo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output Current Io\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output Power Po\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Safe Supply Voltage Um\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Safe Output Voltage Um\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e The 40 V DC Um value represents a maximum safe voltage. It does not replace the 20–30 V DC rated supply requirement.\u003c\/p\u003e\n\u003cp\u003eVerify the complete intrinsically safe circuit parameters before connecting field devices. Check sensor entity parameters, cable capacitance, and cable inductance against the applicable installation requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e5. Environmental and Mechanical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 °C (-4 to +140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 × 119 × 115 mm (W × H × D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 60715:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e6. Indicators and Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e Provide visual operating status information.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIP Switches:\u003c\/strong\u003e Configure the operating mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReversible Operation:\u003c\/strong\u003e Supports selectable signal logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront Labeling Area:\u003c\/strong\u003e Allows equipment identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Rail:\u003c\/strong\u003e Supports supply distribution and collective fault signaling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eStep 1 – Verify Installation Conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the model number matches \u003cstrong\u003eKFD2-ST2-EX2\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eCheck the cabinet temperature and available DIN rail space.\u003c\/li\u003e\n\u003cli\u003eVerify the 20–30 V DC supply voltage.\u003c\/li\u003e\n\u003cli\u003eReview hazardous-area wiring requirements before installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStep 2 – Mount the Interface\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module on a standard 35 mm DIN rail.\u003c\/li\u003e\n\u003cli\u003eEnsure secure mechanical engagement.\u003c\/li\u003e\n\u003cli\u003eMaintain sufficient space for wiring and ventilation.\u003c\/li\u003e\n\u003cli\u003eProtect the IP20 enclosure from moisture and conductive contamination.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStep 3 – Connect Field Sensors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnect channel 1 using terminals 1+, 2+, and 3-.\u003c\/li\u003e\n\u003cli\u003eConnect channel 2 using terminals 4+, 5+, and 6-.\u003c\/li\u003e\n\u003cli\u003eObserve the correct polarity for NAMUR sensors.\u003c\/li\u003e\n\u003cli\u003eUse suitable resistor arrangements for compatible dry-contact LFD monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStep 4 – Connect Control-Side Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnect output I through terminal 7+.\u003c\/li\u003e\n\u003cli\u003eConnect output II through terminal 9+.\u003c\/li\u003e\n\u003cli\u003eCheck the shared electrical reference at terminal 14+.\u003c\/li\u003e\n\u003cli\u003eVerify PLC input compatibility with active transistor outputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStep 5 – Apply Power\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the supply through Power Rail or terminals 14+ and 15-.\u003c\/li\u003e\n\u003cli\u003eVerify supply polarity and voltage.\u003c\/li\u003e\n\u003cli\u003eInspect LED indications after energization.\u003c\/li\u003e\n\u003cli\u003eTest each input and its corresponding output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/KFD2-ST2-Ex2.png?v=1795145409\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":68111197962422,"sku":"KFD2-ST2-EX2","price":96.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/KFD2-ST2-Ex2-1.jpg?v=1795145409","url":"https:\/\/www.plcsparehub.com\/products\/pepperl-fuchs-kfd2-st2-ex2-isolated-namur-input-amplifier-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}