{"product_id":"pepperl-fuchs-kfa6-sr2-ex1-w-lb-namur-switch-amplifier","title":"Pepperl+Fuchs KFA6-SR2-Ex1.W.LB NAMUR Switch Amplifier","description":"\u003ch3\u003e\u003cstrong\u003eProduct Introduction\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0084cc;\"\u003ePepperl+Fuchs KFA6-SR2-Ex1.W.LB\u003c\/span\u003e\u003c\/strong\u003e (Part No. \u003cstrong\u003e103375\u003c\/strong\u003e) is a single-channel switch amplifier and isolated barrier. It interfaces NAMUR sensors or mechanical dry contacts with control systems. The module provides relay switching, electrical isolation, and field wiring diagnostics.\u003c\/p\u003e\n\u003cp\u003eDesigned for industrial applications, this unit monitors digital input signals from hazardous areas. Its integrated Line Fault Detection (LFD) identifies field wiring breaks and short circuits. Two relay outputs support process switching and fault signaling. Engineers can configure the operating mode through onboard switches.\u003c\/p\u003e\n\u003cp\u003eThe module operates from a \u003cstrong\u003e230 V AC supply\u003c\/strong\u003e and supports safety applications up to \u003cstrong\u003eSIL 2\u003c\/strong\u003e according to IEC 61508. Its compact housing supports DIN rail installation inside industrial control cabinets.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eKFA6-SR2-Ex1.W.LB\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e103375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK-System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-channel Switch Amplifier \/ Isolated Barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNAMUR Sensors \/ Mechanical Dry Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSignal or Fault Indication Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e207–253 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45–65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Integrity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to SIL 2, IEC 61508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Fault Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen-Circuit and Short-Circuit Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 × 119 × 115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Signal Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe input circuit accepts NAMUR proximity sensors according to EN 60947-5-6. It also supports compatible mechanical dry contacts.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1+, 2+, 3-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAMUR Open-Circuit Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2–2.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Hysteresis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen-Circuit Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Current ≤ 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Current \u0026gt; 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Pulse Duration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Pause Duration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eRelay Output Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides two independent relay contact groups. Output I handles the switching signal. Output II provides a switching signal or fault indication.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput I Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7, 8, 9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput II Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, 11, 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Contact Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e253 V AC \/ 2 A, cos φ \u0026gt; 0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlternative AC Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e126.5 V AC \/ 4 A, cos φ \u0026gt; 0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Contact Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 V DC \/ 2 A, Resistive Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperate Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelease Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Switching Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Service Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10⁷ Switching Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Isolation and Ex Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eKFA6-SR2-Ex1.W.LB\u003c\/strong\u003e provides galvanic isolation between field circuits and control-side connections.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput-to-Output:\u003c\/strong\u003e Safe electrical isolation according to IEC\/EN 60079-11.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput-to-Supply:\u003c\/strong\u003e Safe electrical isolation according to IEC\/EN 60079-11.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput-to-Supply:\u003c\/strong\u003e Reinforced insulation according to IEC 61140.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput-to-Output:\u003c\/strong\u003e Basic insulation according to IEC 61140.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage:\u003c\/strong\u003e 300 V RMS for the specified output isolation ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEx Input Voltage Uo:\u003c\/strong\u003e 10.6 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEx Input Current Io:\u003c\/strong\u003e 19.1 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEx Input Power Po:\u003c\/strong\u003e 51 mW, linear characteristic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Safe Supply Voltage Um:\u003c\/strong\u003e 253 V AC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe input circuit supports intrinsically safe field connections. Its protection parameters must match the connected field device and installation requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Functional Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNAMUR Signal Conditioning:\u003c\/strong\u003e Converts field sensor signals into relay switching outputs for control applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated LFD:\u003c\/strong\u003e Detects open circuits and short circuits in monitored field wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Relay Outputs:\u003c\/strong\u003e Separates process switching from additional signal or fault indication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReversible Operating Mode:\u003c\/strong\u003e Allows engineers to select the required switching behavior through onboard configuration switches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Fault Monitoring:\u003c\/strong\u003e Supports adjustment of operating and monitoring functions through designated switches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIL 2 Capability:\u003c\/strong\u003e Supports safety-related applications when the complete system meets applicable requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Installation:\u003c\/strong\u003e Its 20 mm housing width helps conserve cabinet space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the Model:\u003c\/strong\u003e Confirm the KFA6-SR2-Ex1.W.LB designation and part number 103375.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the Supply:\u003c\/strong\u003e Confirm a 207–253 V AC supply at 45–65 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMount the Module:\u003c\/strong\u003e Secure the housing onto a compatible DIN rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect the Input:\u003c\/strong\u003e Wire the NAMUR sensor or dry contact to terminals 1+, 2+, and 3-.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect the Supply:\u003c\/strong\u003e Use terminals 14 and 15 for the AC power connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Output I:\u003c\/strong\u003e Connect the process relay circuit to terminals 7, 8, and 9.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Output II:\u003c\/strong\u003e Connect the signal or fault relay circuit to terminals 10, 11, and 12.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify Configuration:\u003c\/strong\u003e Check the S1 and S3 switch settings against the application requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect Wiring:\u003c\/strong\u003e Verify terminal tightness, polarity, and circuit separation before energizing.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Note:\u003c\/strong\u003e Qualified personnel must perform installation and commissioning. Follow applicable hazardous-area regulations and intrinsically safe circuit requirements. Disconnect power before changing wiring or configuration switches.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":68111180333238,"sku":"KFA6-SR2-Ex1.W.LB","price":106.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/KFA6-SR2-EX1.W.LB-1.jpg?v=1795145036","url":"https:\/\/www.plcsparehub.com\/products\/pepperl-fuchs-kfa6-sr2-ex1-w-lb-namur-switch-amplifier","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}