{"product_id":"pcl45usb-mtl-configurator-atex-usb-interface-for-mtl4000-mtl5500","title":"PCL45USB MTL Configurator – ATEX USB Interface for MTL4000 \u0026 MTL5500","description":"\u003ch3\u003e\u003cstrong\u003eMTL PCL45USB – USB Configuration Interface for Industrial Signal Converters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #1677cc;\"\u003ePCL45USB\u003c\/span\u003e\u003c\/strong\u003e is an ATEX-certified configuration interface developed for MTL industrial signal converters. It connects compatible converters to a standard Windows-based PC through USB.\u003c\/p\u003e\n\u003cp\u003eThe configuration package combines the \u003cstrong\u003ePCS45 software\u003c\/strong\u003e with the \u003cstrong\u003ePCL45USB hardware interface\u003c\/strong\u003e. Engineers can configure supported converters from the safe area while equipment remains online.\u003c\/p\u003e\n\u003cp\u003eThe system supports four major product families: \u003cstrong\u003eMTL4000, MTL4500, MTL5000, and MTL5500\u003c\/strong\u003e. Users can save configuration files to disk and print configuration records for maintenance documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Configuration Architecture and Operating Principle\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Component\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS45 Software\u003c\/td\u003e\n\u003ctd\u003eProvides the PC-based configuration environment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCL45USB Interface\u003c\/td\u003e\n\u003ctd\u003eConnects the computer to compatible MTL converters.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Connection\u003c\/td\u003e\n\u003ctd\u003eProvides the communication link between the PC and interface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3.5 mm Jack Connection\u003c\/td\u003e\n\u003ctd\u003eConnects the interface to supported MTL4500 and MTL5500 converters.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter Cable\u003c\/td\u003e\n\u003ctd\u003eSupports earlier MTL converter connection arrangements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Storage\u003c\/td\u003e\n\u003ctd\u003eAllows engineers to save settings to disk.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrint Function\u003c\/td\u003e\n\u003ctd\u003eProduces configuration records for maintenance documentation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Advantage:\u003c\/strong\u003e Engineers can access converter settings without relocating field equipment to a workshop. Online configuration also supports maintenance activities during normal equipment operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMTL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #1677cc;\"\u003ePCL45USB\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Configuration Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoftware Package\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePCS45 Configuration Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATEX certified interfacing link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafe area\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePC Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Type-B female socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConverter Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-pole, 3.5 mm jackplug for MTL4500 and MTL5500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLegacy Converter Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdapter cable supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFitted Converter Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupplied USB Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 m, USB Type-A male to Type-B male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−10°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Converter Families\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMTL4000, MTL4500, MTL5000, MTL5500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | PCS45 Software and PC Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe PCS45 software provides the configuration environment for supported MTL converters. The original package supplies the software on CD.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoftware Item\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRequirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating System\u003c\/td\u003e\n\u003ctd\u003eMicrosoft Windows 2000, Windows XP, or Windows 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHard Disk Space\u003c\/td\u003e\n\u003ctd\u003eMinimum 20 MB available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Drive\u003c\/td\u003e\n\u003ctd\u003eCD-ROM drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Interface\u003c\/td\u003e\n\u003ctd\u003eOne available USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinting\u003c\/td\u003e\n\u003ctd\u003eLocal or network printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Medium\u003c\/td\u003e\n\u003ctd\u003ePCS45 installation CD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Updates\u003c\/td\u003e\n\u003ctd\u003eManufacturer update resources at www.mtl-inst.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eOperating System Note:\u003c\/strong\u003e The listed compatibility covers Windows 2000, XP, and Windows 7. Consult MTL before using other operating systems, including Windows Vista.\u003c\/p\u003e\n\u003cp\u003eFor newer Windows computers, verify USB driver recognition and software compatibility before scheduling field configuration work.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Converter Compatibility and Connection Details\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe interface supports four MTL converter families. Connector arrangements vary between product generations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTL4000 Series:\u003c\/strong\u003e Supported through the supplied adapter cable for earlier converter designs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTL4500 Series:\u003c\/strong\u003e Uses the fitted three-pole, 3.5 mm jackplug connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTL5000 Series:\u003c\/strong\u003e Included in the supported converter family range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTL5500 Series:\u003c\/strong\u003e Uses the fitted three-pole, 3.5 mm jackplug connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility Warning:\u003c\/strong\u003e Series compatibility does not guarantee identical connector arrangements across every model. Verify the converter part number and required adapter before connection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Installation and Configuration Procedure\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFollow a controlled connection sequence to reduce configuration errors and unnecessary equipment handling.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrepare the PC:\u003c\/strong\u003e Confirm the Windows version and available USB port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall PCS45:\u003c\/strong\u003e Use the supplied CD and follow the software installation instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect USB:\u003c\/strong\u003e Attach the USB Type-A to Type-B cable to the PC and interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelect the Converter Cable:\u003c\/strong\u003e Use the fitted jackplug or supplied adapter cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect the Converter:\u003c\/strong\u003e Verify the correct connection for the selected MTL family.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart Configuration:\u003c\/strong\u003e Open PCS45 and establish communication with the converter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify Parameters:\u003c\/strong\u003e Review existing settings before making changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSave Records:\u003c\/strong\u003e Store the configuration file and print a maintenance copy when required.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Recommendation:\u003c\/strong\u003e Save the original configuration before modifying operating parameters. Compare the revised settings against approved process documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Maintenance and Troubleshooting Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eObserved Condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Inspection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC does not recognize the interface\u003c\/td\u003e\n\u003ctd\u003eCheck USB connections, port availability, and driver recognition.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS45 cannot communicate\u003c\/td\u003e\n\u003ctd\u003eVerify converter selection and cable compatibility.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection fails on older converters\u003c\/td\u003e\n\u003ctd\u003eCheck the supplied adapter cable and connector arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware installation fails\u003c\/td\u003e\n\u003ctd\u003eReview operating system compatibility and installation requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration records are unavailable\u003c\/td\u003e\n\u003ctd\u003eCheck disk permissions and available storage space.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinted records are incomplete\u003c\/td\u003e\n\u003ctd\u003eVerify printer connectivity and output settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003eInspect connector contacts for contamination and mechanical damage.\u003c\/li\u003e\n\u003cli\u003eKeep the USB and converter cables free from excessive bending.\u003c\/li\u003e\n\u003cli\u003eStore the interface within its specified temperature limits.\u003c\/li\u003e\n\u003cli\u003eMaintain backup copies of verified converter configurations.\u003c\/li\u003e\n\u003cli\u003eUse approved configuration procedures when modifying live equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Certification and Application Boundaries\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1677cc;\"\u003ePCL45USB\u003c\/span\u003e\u003c\/strong\u003e interfacing link carries ATEX certification. Its specified installation location is the safe area.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e ATEX-certified interface hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Boundary:\u003c\/strong\u003e Safe-area use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Platform:\u003c\/strong\u003e Windows-based PC configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Configuration and maintenance of compatible MTL converters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not interpret interface certification as approval for unrestricted hazardous-area PC installation. Follow the applicable certification documentation and site safety procedures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Package Contents and Supply Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ePCL45USB ATEX-certified interfacing link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003ePCS45 configuration software CD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e2 m USB Type-A male to Type-B male cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e1.5 m fitted converter connection cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eAdapter cable for earlier MTL converter models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Note:\u003c\/strong\u003e Confirm the complete accessory configuration when requesting a quotation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1. Can engineers change converter settings without disconnecting the converter from the operating system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The interface supports configuration from the safe area while converters remain online. Engineers should still follow site-approved change management procedures. Verify process stability before modifying critical parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2. Why does the PCL45USB use different converter-side connectors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMTL converter generations use different configuration connection arrangements. The fitted three-pole jackplug supports MTL4500 and MTL5500 connections. The supplied adapter accommodates earlier converter designs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3. What should engineers check when replacing an older configuration interface?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the original interface model, converter family, connector type, cable arrangement, and software version. Also verify the replacement PC supports the required PCS45 environment. Matching the USB connection alone does not establish complete compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4. Why should engineers save configuration files before field adjustments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBackup files provide a reference for troubleshooting and parameter recovery. They also help maintenance teams compare approved settings against current operating values. Use clear filenames containing converter identification and revision information.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5. Is the PCL45USB suitable for modern Windows computers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe documented PCS45 compatibility lists Windows 2000, XP, and Windows 7. Newer operating systems require compatibility verification. Check software installation, USB driver recognition, and communication operation before purchasing for modern maintenance work.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Purchasing and Model Selection Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBefore ordering, confirm the following technical details with your maintenance or instrumentation team.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface Model:\u003c\/strong\u003e PCL45USB.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Requirement:\u003c\/strong\u003e PCS45 configuration software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConverter Family:\u003c\/strong\u003e MTL4000, MTL4500, MTL5000, or MTL5500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Three-pole jackplug or required adapter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComputer Platform:\u003c\/strong\u003e Compatible Windows PC with an available USB port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessory Requirement:\u003c\/strong\u003e Confirm USB cable, fitted cable, adapter, and software CD.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRequest a Quote:\u003c\/strong\u003e Contact our sales team for \u003cstrong\u003ePCL45USB\u003c\/strong\u003e pricing, availability, and configuration accessory confirmation.\u003c\/p\u003e\n\u003cp\u003eWe support industrial automation spare-part sourcing and international delivery. Contact us with your converter model to help verify the required configuration interface.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/PCL45USB.png?v=1794453293\" alt=\"\"\u003e\u003c\/p\u003e","brand":"MTL","offers":[{"title":"Default Title","offer_id":68045629391030,"sku":"PCL45USB","price":113.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/PCL45USB-1_0097fdbf-7dca-4b70-9a29-caa3602d7b0a.jpg?v=1794453314","url":"https:\/\/www.plcsparehub.com\/products\/pcl45usb-mtl-configurator-atex-usb-interface-for-mtl4000-mtl5500","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}