{"product_id":"p-lb-2-a-1346-pepperl-fuchs-p-lb-series-2-channel-surge-protection-barrier","title":"P-LB-2.A.1346 Pepperl+Fuchs P-LB Series 2-Channel Surge Protection Barrier","description":"\u003ch3\u003e\u003cstrong\u003eEngineering Architecture \u0026amp; System Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInstrumentation engineers deploy the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eP-LB-2.A.1346\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003ePepperl+Fuchs\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eP-LB Series\u003c\/strong\u003e\u003c\/span\u003e 2-channel surge protection barrier to safeguard sensitive control system inputs against transient lightning strikes and heavy inductive switching surges. Designed for seamless plug-in mounting directly onto the field side of \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eKF modules\u003c\/strong\u003e\u003c\/span\u003e, this compact barrier intercepts surges up to 10 kA per conductor on leads 1, 3, 4, and 6 without introducing signal degradation. Its automatic reset mechanism guarantees uninterruptible loop operation across critical process automation loops.\u003c\/p\u003e\n\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" width=\"100%\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth align=\"left\"\u003eFunctional Domain\u003c\/th\u003e\n      \u003cth align=\"left\"\u003eEngineering Parameter\u003c\/th\u003e\n      \u003cth align=\"left\"\u003eTechnical Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIdentification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBrand, Model \u0026amp; Part Number\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003ePepperl+Fuchs P-LB-2.A.1346\u003c\/strong\u003e\u003c\/span\u003e (P-LB-2.A1346 \/ 103638)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArchitecture\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eProduct Series \u0026amp; Type\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eP-LB Series\u003c\/strong\u003e\u003c\/span\u003e 2-Channel Surge Protection Barrier\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVoltage \u0026amp; Current Ratings\u003c\/td\u003e\n      \u003ctd\u003eMax 30 V DC rated voltage; Max 250 mA operating current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSurge Capacity \u0026amp; Leakage\u003c\/td\u003e\n      \u003ctd\u003e10 kA per conductor peak pulse; Max 5 µA leakage current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePhysical Dimensions \u0026amp; Mass\u003c\/td\u003e\n      \u003ctd\u003e20 × 104 × 127 mm modular housing; Approx. 70 g net weight\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eThermal Range \u0026amp; Ingress\u003c\/td\u003e\n      \u003ctd\u003e-20 °C to +60 °C ambient operating span; IP20 enclosure rating\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFunctional \u0026amp; Hazardous Approvals\u003c\/td\u003e\n      \u003ctd\u003eSIL 3 per IEC\/EN 61508; ATEX \/ IECEx certified (Ex ia\/nA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Implementation \u0026amp; Operational Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Plug-in Topology:\u003c\/strong\u003e Eliminates external DIN-rail terminal blocks by mounting directly onto standard K-System (KF) barrier housings, preserving precious control cabinet footprint.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUninterrupted Signal Loop:\u003c\/strong\u003e Features automatic self-resetting surge diversion networks that recover instantly after transient suppression without requiring manual fuse replacement.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Channel Versatility:\u003c\/strong\u003e Handles both analog 4-20 mA control loops and digital discrete input\/output signals with ultra-low series resistance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExplosion Protection Compliance:\u003c\/strong\u003e Certified for intrinsic safety (Ex ia) and non-sparking (Ex nA) installations within Zone 2 hazardous process environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eAdvanced Field Engineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How does plugging the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eP-LB-2.A.1346\u003c\/strong\u003e\u003c\/span\u003e barrier onto a KF module affect loop resistance and transmitter calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The internal protective components add minimal series resistance to the circuit. For standard 4-20 mA loops, this voltage drop is negligible and does not require recalibrating field transmitters or DCS analog input cards.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can I use this barrier in safety-instrumented functions requiring SIL certification?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes, the unit is independently certified to SIL 3 per IEC\/EN 61508, making it fully compatible with safety instrumented systems (SIS) in emergency shutdown (ESD) applications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What maintenance checks should instrument technicians perform on these barriers after a severe electrical storm?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Measure the leakage current across the terminals. If leakage exceeds the 5 µA threshold or if the internal diagnostic monitoring indicates a degraded suppression stage, replace the plug-in module immediately.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: Why does the unit have an IP20 rating if it is installed in harsh industrial cabinets?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: An IP20 rating assumes the module resides inside a sealed, weather-proof control panel or cabinet. The cabinet protects against dust and moisture, while the IP20 housing prevents accidental finger contact with live terminals.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: How do I verify that the grounding path for the surge barrier is properly established?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA5: Ensure the base K-System mounting rail is bonded to a low-impedance copper ground busbar. The surge current collected by the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eP-LB-2.A.1346\u003c\/strong\u003e\u003c\/span\u003e discharges directly through the DIN rail mounting foot into the cabinet ground.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":68083438321846,"sku":"P-LB-2.A.1346","price":113.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/P.LB.2.A1346-1.jpg?v=1794901922","url":"https:\/\/www.plcsparehub.com\/products\/p-lb-2-a-1346-pepperl-fuchs-p-lb-series-2-channel-surge-protection-barrier","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}