{"product_id":"oid200-ifm-oid-photoelectric-distance-sensor-laser-tof-with-io-link","title":"OID200 ifm OID Photoelectric Distance Sensor Laser ToF with IO-Link","description":"\u003ch3\u003e\u003cstrong\u003eOID200 | ifm OID Photoelectric Distance Sensor with IO-Link\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0070c0;\"\u003eifm OID200\u003c\/span\u003e\u003c\/strong\u003e is a laser-based photoelectric distance sensor designed for industrial object detection and distance measurement. It uses time-of-flight (ToF) technology and background suppression to evaluate targets within its specified measuring range.\u003c\/p\u003e\n\u003cp\u003eWith a measuring range of 0.03 to 2 m, an M30 threaded housing, and integrated IO-Link communication, the \u003cstrong\u003eOID200\u003c\/strong\u003e supports machine automation tasks that require non-contact distance feedback. Its two PNP switching outputs provide discrete control signals, while IO-Link transfers process data and supports parameter access.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering reference:\u003c\/strong\u003e OIDLCPKG\/US. Confirm the exact order code, model designation, and regional version against the manufacturer's documentation before placing an order.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Measurement Capability at a Glance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement Feature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eEngineering Significance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring principle\u003c\/td\u003e\n\u003ctd\u003eLaser time-of-flight (ToF)\u003c\/td\u003e\n\u003ctd\u003eMeasures distance without physical contact with the target.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.03–2 m\u003c\/td\u003e\n\u003ctd\u003eSupports distance monitoring within the specified operating range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackground suppression\u003c\/td\u003e\n\u003ctd\u003eSpecified in supplied data as \u0026lt; 20 m\u003c\/td\u003e\n\u003ctd\u003eVerify the exact background-suppression definition and limit in the manufacturer's datasheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source\u003c\/td\u003e\n\u003ctd\u003eRed laser, 650 nm\u003c\/td\u003e\n\u003ctd\u003eProvides a visible aiming point for installation and alignment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser classification\u003c\/td\u003e\n\u003ctd\u003eClass 2, maximum output ≤ 4.0 mW as supplied\u003c\/td\u003e\n\u003ctd\u003eFollow the manufacturer's laser safety instructions and applicable standards.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling rate\u003c\/td\u003e\n\u003ctd\u003e33 Hz\u003c\/td\u003e\n\u003ctd\u003eDefines the stated measurement sampling rate.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching frequency\u003c\/td\u003e\n\u003ctd\u003e11 Hz\u003c\/td\u003e\n\u003ctd\u003eConsider this limit when evaluating response requirements for moving targets.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection hysteresis\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2%; black target at 6% remission background noted\u003c\/td\u003e\n\u003ctd\u003eTarget reflectivity can influence switching behavior and repeatability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum light spot diameter\u003c\/td\u003e\n\u003ctd\u003e5 mm at 2 m\u003c\/td\u003e\n\u003ctd\u003eCheck target size and alignment at the maximum measurement distance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient light immunity\u003c\/td\u003e\n\u003ctd\u003eUp to 10 klx on the object\u003c\/td\u003e\n\u003ctd\u003eEvaluate performance under the actual lighting conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical light source lifetime\u003c\/td\u003e\n\u003ctd\u003e50,000 hours\u003c\/td\u003e\n\u003ctd\u003eUse this figure as a typical source-life specification, not a guaranteed sensor service life.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Mechanical Design and Installation Envelope\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe cylindrical M30 housing simplifies integration into compatible machine brackets and threaded mounting points. The supplied package includes two stainless steel M30 lock nuts for mounting.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing format:\u003c\/strong\u003e M30 × 1.5 threaded cylinder.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall length:\u003c\/strong\u003e 100 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 207 g.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Stainless steel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront pane:\u003c\/strong\u003e PMMA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED window:\u003c\/strong\u003e PC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOther listed materials:\u003c\/strong\u003e PBT and FKM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical connection:\u003c\/strong\u003e One M12 A-coded, four-pin connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress protection:\u003c\/strong\u003e IP65 and IP67, as specified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBefore installation, check the available mounting depth, connector clearance, target alignment, and cable bend space. Confirm chemical compatibility for exposed materials when the sensor operates near cleaning agents, oils, or process fluids.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Electrical Interface and Switching Logic\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical Parameter\u003c\/th\u003e\n\u003cth\u003eRated Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e10–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd\u003e75 mA at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput configuration\u003c\/td\u003e\n\u003ctd\u003e2 × PNP, complementary NO\/NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output load\u003c\/td\u003e\n\u003ctd\u003e100 mA per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching frequency\u003c\/td\u003e\n\u003ctd\u003e11 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit protection\u003c\/td\u003e\n\u003ctd\u003eYes, pulsed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse-polarity protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC reference\u003c\/td\u003e\n\u003ctd\u003eEN 60947-5-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTTF\u003c\/td\u003e\n\u003ctd\u003e239 years, as specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe complementary PNP outputs can support PLC input logic and object-state monitoring. Verify the required NO\/NC behavior, input voltage compatibility, and channel current limits before wiring the sensor.\u003c\/p\u003e\n\u003cp\u003eDo not treat the 33 Hz sampling rate as the switching frequency. The supplied specifications list these as separate parameters, and application response must meet the actual switching requirement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | IO-Link Communication and Process Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe OID200 integrates an IO-Link interface through its M12 A-coded four-pin connector. It supports IO-Link communication and standard SIO operation, allowing integration into systems that use either IO-Link process data or conventional switching signals.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIO-Link revision\u003c\/td\u003e\n\u003ctd\u003e1.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission rate\u003c\/td\u003e\n\u003ctd\u003eCOM2, 38.4 kBaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSIO mode\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor profile\u003c\/td\u003e\n\u003ctd\u003eSSP 0, generic profiled sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault DeviceID\u003c\/td\u003e\n\u003ctd\u003e373\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum process cycle\u003c\/td\u003e\n\u003ctd\u003e6.4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess data\u003c\/td\u003e\n\u003ctd\u003eOne analogue value and one binary value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication expansion\u003c\/td\u003e\n\u003ctd\u003eNo separate expansion interface listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor IO-Link integration, confirm the master port configuration, sensor DeviceID, process-data mapping, and PLC variable assignment. Use the manufacturer's IODD and device documentation when available to configure parameters correctly.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Suitable Equipment and Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyor systems:\u003c\/strong\u003e Monitor object distance or presence at transfer points and inspection stations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging machinery:\u003c\/strong\u003e Check product position and support non-contact detection where the target falls within the rated range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly automation:\u003c\/strong\u003e Provide distance feedback for workpiece positioning and sequence checks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial handling:\u003c\/strong\u003e Detect objects at defined distances on automated handling equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine tending:\u003c\/strong\u003e Support presence or position checks around fixtures and loading stations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLC-controlled inspection stations:\u003c\/strong\u003e Deliver switching signals and IO-Link process data for control logic and monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplication suitability depends on target dimensions, surface reflectivity, installation angle, ambient light, and required response time. Validate performance with the actual workpiece rather than relying only on nominal range.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Field Diagnostics and Commissioning Workflow\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen the sensor reports an incorrect distance or produces unstable switching, check the optical setup before changing PLC logic. Surface properties, alignment, supply voltage, and communication configuration can all affect system behavior.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved Symptom\u003c\/th\u003e\n\u003cth\u003eChecks to Perform\u003c\/th\u003e\n\u003cth\u003eDiagnostic Purpose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo detection at the target\u003c\/td\u003e\n\u003ctd\u003eCheck the 10–30 V DC supply, target position, and measurement range.\u003c\/td\u003e\n\u003ctd\u003eSeparate power and alignment issues from range limitations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent switching\u003c\/td\u003e\n\u003ctd\u003eInspect target reflectivity, vibration, alignment, and ambient light.\u003c\/td\u003e\n\u003ctd\u003eIdentify optical conditions that may destabilize detection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncorrect PLC input state\u003c\/td\u003e\n\u003ctd\u003eVerify PNP input compatibility, NO\/NC logic, and wiring.\u003c\/td\u003e\n\u003ctd\u003eDistinguish output-logic errors from measurement problems.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMissing IO-Link process data\u003c\/td\u003e\n\u003ctd\u003eCheck the master port mode, M12 connection, DeviceID, and process-data mapping.\u003c\/td\u003e\n\u003ctd\u003eIdentify configuration or communication faults.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnexpected response on fast-moving targets\u003c\/td\u003e\n\u003ctd\u003eCompare the application cycle with the specified 11 Hz switching frequency.\u003c\/td\u003e\n\u003ctd\u003eDetermine whether the sensor meets the required response rate.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor inactive during cold startup\u003c\/td\u003e\n\u003ctd\u003eCheck ambient temperature and the warm-up requirement below −10 °C.\u003c\/td\u003e\n\u003ctd\u003eConfirm whether the sensor is operating within its startup conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe yellow LED indicates the switching output associated with pin 4, while the green LED indicates operation. The display supports centimetre or inch units, and the setting ring provides local adjustment.\u003c\/p\u003e\n\u003cp\u003eAt ambient temperatures below −10 °C, the supplied specification states that warm-up is required and the laser remains off during this period. Follow the manufacturer's startup instructions before diagnosing a suspected failure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Global PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIn practical machine integration, the most common selection mistake is choosing a distance sensor by range alone. The OID200's 2 m maximum range does not guarantee stable detection on every surface or at every angle.\u003c\/p\u003e\n\u003cp\u003eFor conveyor applications, test the smallest and least reflective workpieces at the actual installation distance. Check the 5 mm maximum light spot diameter at 2 m against the target's usable surface area.\u003c\/p\u003e\n\u003cp\u003eFor PLC projects, assess the switching frequency separately from the IO-Link process cycle. A communication cycle of 6.4 ms does not automatically mean the physical output can switch at the same rate.\u003c\/p\u003e\n\u003cp\u003eFor replacement projects, compare the model, order code, connector, mounting dimensions, output type, and IO-Link settings. Confirm the device identity before downloading parameters or changing a master-port configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Environmental Limits and Selection Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironmental Item\u003c\/th\u003e\n\u003cth\u003eSpecification or Limitation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−25 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold-start condition\u003c\/td\u003e\n\u003ctd\u003eWarm-up required below −10 °C; laser off during warm-up, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003eNot listed in the supplied technical data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003eNot listed in the supplied technical data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP65 and IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser safety\u003c\/td\u003e\n\u003ctd\u003eClass 2; observe manufacturer safety instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eDo not infer a storage-temperature or relative-humidity rating from the operating-temperature range. Consult the manufacturer's documentation when the installation requires defined storage or humidity limits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Product Identification, Warranty and Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ifm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e OID200\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e OID photoelectric distance sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Laser time-of-flight distance sensor with background suppression and IO-Link\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrdering reference supplied:\u003c\/strong\u003e OIDLCPKG\/US; verify against the exact model and regional order code before purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months, subject to the seller's written warranty terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping methods:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and shipping arrangements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage contents:\u003c\/strong\u003e Confirm the exact supplied accessories and mounting hardware with the seller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How should I select the measuring range for a real machine installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Measure the minimum and maximum target distances, then allow for mechanical tolerances and target movement. Test representative workpieces under actual lighting conditions before approving the installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Will the OID200 detect dark or low-reflectivity objects reliably?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Performance depends on surface reflectivity, target geometry, and installation conditions. Validate the least reflective target during commissioning rather than assuming every object performs identically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can I connect the sensor directly to a standard PLC digital input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The sensor provides PNP switching outputs, but the PLC input must support the required voltage and current. Confirm the wiring diagram and NO\/NC logic before connecting the device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What should I check before replacing an existing IO-Link sensor with this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Compare the measuring range, housing dimensions, connector, output logic, process-data format, and master compatibility. Also verify the exact order code and device identity before reusing stored parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What information helps diagnose a sensor that works locally but fails through IO-Link?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Record the master model, port mode, device identification, connection status, and process-data mapping. Check the M12 cable and master diagnostics before replacing the sensor.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRequest a Quote from Global PLC Spare HUB\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eContact Global PLC Spare HUB for pricing, order-code verification, and compatibility guidance for the ifm OID200. Include your application distance, target material, PLC or IO-Link master model, and required quantity to support a more accurate selection.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/OID200.png?v=1792647950\" alt=\"\"\u003e\u003c\/p\u003e","brand":"IFM","offers":[{"title":"Default Title","offer_id":67717509349558,"sku":"OID200","price":105.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/OID200-3.jpg?v=1792647936","url":"https:\/\/www.plcsparehub.com\/products\/oid200-ifm-oid-photoelectric-distance-sensor-laser-tof-with-io-link","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}