{"product_id":"nfpw442-50-yokogawa-centum-series-power-supply","title":"NFPW442-50 Yokogawa CENTUM Series Power Supply","description":"\u003ch3\u003e\u003cb\u003eYokogawa NFPW442-50 Power Supply Module\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa NFPW442-50\u003c\/strong\u003e is an AC-input power supply module designed for compatible Yokogawa control system installations. It accepts a nominal 220–240 V AC supply and provides a regulated +5.1 V DC output for system electronics.\u003c\/p\u003e\n\u003cp\u003eThe module also provides a separate 24 V DC analog field power supply path. Its electrical protection functions include overvoltage protection, overcurrent protection and input-side protection. A duplex configuration is possible when the module is installed on the specified \u003cstrong\u003eNFBU200 base module\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWith a rated output of 40 W and a peak output capability of 60 W, the NFPW442-50 is intended for applications requiring stable DC power within a Yokogawa system architecture.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e01 | Model Identification and Configuration Breakdown\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCode Section\u003c\/th\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNFPW442\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Code\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e442\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220–240 V AC input model designation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix Code\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard type without explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption Code\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eComplete model:\u003c\/strong\u003e NFPW442-50\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Breakdown\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNFPW442\u003c\/strong\u003e – Yokogawa power supply module for 220–240 V AC input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-5\u003c\/strong\u003e – Standard type without explosion protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0\u003c\/strong\u003e – Basic type.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSelection note:\u003c\/strong\u003e When ordering a replacement, compare the complete model designation, including suffix and option codes. Do not select the module based only on the NFPW442 base model.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e02 | AC Input Performance\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e170–264 V AC (rms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47–66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e0.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Rating\u003c\/td\u003e\n\u003ctd\u003e3.15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n\u003ctd\u003e90 A for 5 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Leakage Current\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e3,000 V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e50 MΩ at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMomentary Power-Failure Immunity\u003c\/td\u003e\n\u003ctd\u003e10 ms at 80% condition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003e03 | Main DC Output – +5.1 V Rail\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe primary output supplies the DC power required by compatible system electronics. Its rated output current is 7.8 A, with a specified peak current of 11.8 A.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Parameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e+5.1 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e0–7.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Output Current\u003c\/td\u003e\n\u003ctd\u003e11.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Rated Output Power\u003c\/td\u003e\n\u003ctd\u003e40 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Output Power\u003c\/td\u003e\n\u003ctd\u003e60 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003eMaximum 7 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercurrent Protection\u003c\/td\u003e\n\u003ctd\u003eMinimum 105%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercurrent Response\u003c\/td\u003e\n\u003ctd\u003eShutdown after 4–14 seconds of sustained overcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Time\u003c\/td\u003e\n\u003ctd\u003eMaximum 300 ms after power-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRestart Time After 200 ms Power Failure\u003c\/td\u003e\n\u003ctd\u003eMaximum 100 ms under rated input conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003e04 | Analog Field Power Supply\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eIn addition to the primary DC output, the NFPW442-50 provides an analog field power supply input and output path. This supports compatible field-power requirements within the control system configuration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Fuse Rating\u003c\/td\u003e\n\u003ctd\u003e6.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003eInput voltage minus matching-diode voltage drop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Overvoltage Protection\u003c\/td\u003e\n\u003ctd\u003e35 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering consideration:\u003c\/strong\u003e The analog field power output is not a fixed 24 V DC output under all conditions. Its voltage depends on the applied input voltage and the matching-diode voltage drop.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e05 | Redundancy and System Integration\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration Item\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuplex Configuration\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired Base Module\u003c\/td\u003e\n\u003ctd\u003eNFBU200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Condition\u003c\/td\u003e\n\u003ctd\u003eDuplex arrangement when installed on the specified base module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe NFPW442-50 can be used in a duplex power supply arrangement when installed on an NFBU200 base module. Engineers should verify the complete base configuration, wiring arrangement and system power requirements before commissioning.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e06 | Mechanical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFPW442-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e146.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.7 × 130 × 146.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003e07 | Commissioning and Maintenance Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the model code:\u003c\/strong\u003e Verify NFPW442-50 and check the suffix and option configuration against the existing installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure AC input:\u003c\/strong\u003e Confirm that the supply remains within 170–264 V AC rms and that the input frequency is within 47–66 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck input protection:\u003c\/strong\u003e Inspect the specified fuse rating and verify that the upstream protection is suitable for the installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview DC load demand:\u003c\/strong\u003e Calculate the total +5.1 V load current. Check both steady-state demand and any temporary startup peaks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect analog field power:\u003c\/strong\u003e Confirm the external 24 V DC input and check the connected load against the 4 A output rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify duplex installation:\u003c\/strong\u003e If redundancy is required, confirm that the module is installed on the NFBU200 base and that the system wiring supports the intended arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitor restart behavior:\u003c\/strong\u003e During controlled testing, check output recovery after power interruption against the specified startup characteristics.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":68113122984118,"sku":"NFPW442-50","price":296.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/NFPW442-50-1.jpg?v=1795161381","url":"https:\/\/www.plcsparehub.com\/products\/nfpw442-50-yokogawa-centum-series-power-supply","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}