{"product_id":"nfcp502-w05-yokogawa-cpu-module-fcn-ethernet-control-solution","title":"NFCP502-W05 Yokogawa CPU Module | FCN Ethernet Control Solution","description":"\u003ch3\u003e\u003cstrong\u003eNFCP502-W05 | Yokogawa FCN CPU Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1673b9;\"\u003eNFCP502-W05\u003c\/span\u003e\u003c\/strong\u003e is a Yokogawa CPU module designed for the Field Control Node (FCN) platform. It combines an Intel Atom E3815 processor, ECC-protected memory, onboard flash storage, and four Ethernet interfaces in one controller module.\u003c\/p\u003e\n\u003cp\u003eThe module supports FCN control processing and SB bus communication with a duplex I\/O interface. Its communication hardware also includes an RS-232-C serial port, an SDHC card slot, and built-in RAS diagnostic functions.\u003c\/p\u003e\n\u003cp\u003eFor control system engineers, the key selection factors include FCN platform compatibility, Ethernet network architecture, memory configuration, serial communication requirements, and the module's extended-function option.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Configuration Breakdown – Decode NFCP502-W05\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe model number identifies the CPU module family and its hardware configuration. The available product information supports the following breakdown:\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCode segment\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003cth\u003eConfiguration details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNFCP502\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct model\u003c\/td\u003e\n\u003ctd\u003eFCN CPU module with four Ethernet ports.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction option\u003c\/td\u003e\n\u003ctd\u003eWith extended functions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware type\u003c\/td\u003e\n\u003ctd\u003eStandard type.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProtection category\u003c\/td\u003e\n\u003ctd\u003eBasic type without explosion protection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration summary:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCPU platform: NFCP502.\u003c\/li\u003e\n\u003cli\u003eFunction configuration: Extended functions.\u003c\/li\u003e\n\u003cli\u003eHardware classification: Standard type.\u003c\/li\u003e\n\u003cli\u003eProtection classification: Basic type without explosion protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhen replacing an existing module, compare the complete suffix rather than selecting by the NFCP502 family name alone. The W, 0, and 5 configuration details are important for confirming the required hardware variant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Processing and Memory Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe NFCP502-W05 uses an Intel Atom E3815 processor operating at 1.46 GHz. Its memory architecture combines ECC-protected main memory, battery-backed static RAM, and onboard flash storage.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eEngineering function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eIntel Atom E3815, 1.46 GHz\u003c\/td\u003e\n\u003ctd\u003eExecutes controller processing tasks.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain memory\u003c\/td\u003e\n\u003ctd\u003e256 MB with ECC\u003c\/td\u003e\n\u003ctd\u003eProvides working memory with error-checking capability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic RAM\u003c\/td\u003e\n\u003ctd\u003e2 MB with ECC, battery-backed\u003c\/td\u003e\n\u003ctd\u003eProvides backed-up static memory.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary memory\u003c\/td\u003e\n\u003ctd\u003e1 GB onboard flash\u003c\/td\u003e\n\u003ctd\u003eProvides onboard non-volatile storage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal media\u003c\/td\u003e\n\u003ctd\u003e1 SD card slot, SDHC 4–32 GB, Class 10\u003c\/td\u003e\n\u003ctd\u003eSupports compatible removable storage media.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eECC memory supports detection and correction of certain memory errors. This feature is important in industrial control environments where stable controller operation matters.\u003c\/p\u003e\n\u003cp\u003eThe battery-backed SRAM and onboard flash serve different storage roles. Engineers should follow the applicable Yokogawa maintenance procedures when handling battery replacement, storage media, or controller data.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Communication Interfaces – Four Ethernet Ports and Serial Connectivity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides four Ethernet interfaces through RJ45 modular jacks. It supports three Ethernet transmission rates, allowing network design to match the connected infrastructure.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet ports\u003c\/td\u003e\n\u003ctd\u003e4 × RJ45 modular jacks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet standards\u003c\/td\u003e\n\u003ctd\u003e1000BASE-T, 100BASE-TX, 10BASE-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet speeds\u003c\/td\u003e\n\u003ctd\u003e1000 Mbps, 100 Mbps, 10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial interface\u003c\/td\u003e\n\u003ctd\u003e1 × RS-232-C, 9-pin male D-sub connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial communication\u003c\/td\u003e\n\u003ctd\u003eFull-duplex or half-duplex, software selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronization\u003c\/td\u003e\n\u003ctd\u003eAsynchronous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud rates\u003c\/td\u003e\n\u003ctd\u003e0.3, 1.2, 2.4, 4.8, 9.6, 14.4, 19.2, 28.8, 38.4, 57.6, and 115.2 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFour Ethernet ports provide multiple physical network connections. However, port count alone does not establish network redundancy or define the communication topology. Confirm the FCN network design, port assignments, and supported protocols in the system documentation.\u003c\/p\u003e\n\u003cp\u003eThe RS-232-C interface supports serial communication with compatible equipment. Before connecting external devices, verify connector wiring, baud rate, duplex mode, and communication settings at both ends.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | FCN I\/O Interface and System Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe NFCP502-W05 connects to the FCN I\/O architecture through an SB bus duplex interface.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O interface:\u003c\/strong\u003e SB bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus configuration:\u003c\/strong\u003e Duplex.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem role:\u003c\/strong\u003e FCN CPU module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegration point:\u003c\/strong\u003e Compatible FCN control and I\/O hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDuring system engineering, verify the applicable FCN node configuration and connected I\/O hardware. Do not assume that the SB bus interface makes this module interchangeable with CPU modules from other Yokogawa controller families.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | RAS Functions and Front-Panel Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates Reliability, Availability, and Serviceability (RAS) functions. Its diagnostic features include a watchdog timer and temperature monitoring.\u003c\/p\u003e\n\u003cp\u003eThe front panel provides seven LED indicators for checking controller and interface status.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eIndicator\u003c\/th\u003e\n\u003cth\u003eQuantity\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPU status LEDs\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eIndicate CPU operating status.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet status LEDs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eIndicate Ethernet interface status.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD LED\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eIndicates SD media activity or status.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEXEC LED\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eIndicates execution-related status.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe module also includes four physical switches:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRESET switch:\u003c\/strong\u003e Controller reset operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSHUT DOWN switch:\u003c\/strong\u003e Shutdown operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFUNC switch:\u003c\/strong\u003e Function selection or operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEXEC switch:\u003c\/strong\u003e Execution-related operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUse the applicable Yokogawa operating manual to interpret LED patterns and switch procedures. Avoid operating RESET or SHUT DOWN during production without an approved maintenance plan.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Power Supply and Physical Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e5 V DC ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current consumption\u003c\/td\u003e\n\u003ctd\u003e1700 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e1000 mAh graphite fluoride lithium battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPU protection\u003c\/td\u003e\n\u003ctd\u003eCPU cover with wire-lock hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe module requires a regulated 5 V DC supply within the specified tolerance. The maximum current consumption is 1.7 A, so the system power budget should account for this load.\u003c\/p\u003e\n\u003cp\u003eThe CPU cover includes a hole for wire locking. This feature supports physical securing arrangements where required by the cabinet maintenance or equipment protection procedure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Selection and Replacement Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBefore ordering a replacement NFCP502-W05, review the following engineering points:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the FCN platform:\u003c\/strong\u003e Check that the installed system supports the NFCP502 CPU module family.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatch the complete model:\u003c\/strong\u003e Verify the W05 suffix configuration against the installed hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck network requirements:\u003c\/strong\u003e Confirm the four Ethernet connections and required communication speeds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview serial settings:\u003c\/strong\u003e Match RS-232-C wiring, baud rate, and duplex configuration with connected equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck memory and battery requirements:\u003c\/strong\u003e Follow the system backup and battery maintenance procedure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify power capacity:\u003c\/strong\u003e Confirm the 5 V DC supply can support the module's maximum current demand.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor replacement projects, record the existing module model, FCN node configuration, network connections, and relevant system settings before removing hardware. This reduces configuration errors during restoration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Product Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNFCP502-W05\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct family\u003c\/td\u003e\n\u003ctd\u003eNFCP502 FCN CPU module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eCPU module with four Ethernet ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eAtom E3815, 1.46 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain memory\u003c\/td\u003e\n\u003ctd\u003e256 MB ECC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic RAM\u003c\/td\u003e\n\u003ctd\u003e2 MB ECC, battery-backed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard flash\u003c\/td\u003e\n\u003ctd\u003e1 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal storage\u003c\/td\u003e\n\u003ctd\u003e1 × SDHC slot, 4–32 GB, Class 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003ctd\u003e4 × RJ45, 10\/100\/1000 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial port\u003c\/td\u003e\n\u003ctd\u003e1 × RS-232-C, 9-pin male D-sub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O interface\u003c\/td\u003e\n\u003ctd\u003eSB bus, duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e5 V DC ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current\u003c\/td\u003e\n\u003ctd\u003e1700 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e1000 mAh graphite fluoride lithium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAS functions\u003c\/td\u003e\n\u003ctd\u003eWatchdog timer, temperature monitor, and related functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eCPU cover with wire-lock hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How should the four Ethernet ports be evaluated when planning an FCN network?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart with the network topology and the communication requirements of the connected equipment. Identify the intended use of each port, required transmission speed, switch connections, and cable routing. Do not assume that four ports automatically provide four independent networks or automatic failover. Confirm the supported configuration in the FCN engineering documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What should be checked if an RS-232-C device cannot communicate with the CPU module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the D-sub connector pin assignment first, followed by baud rate, duplex mode, and the communication settings of the connected device. Also verify whether the application expects asynchronous serial communication. A mismatch in wiring or serial parameters can prevent communication even when the CPU module operates normally.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What precautions are important when replacing the battery-backed memory support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDo not remove or replace the battery based only on a visual inspection. Follow Yokogawa's approved battery replacement procedure and check the system's backup requirements first. Confirm the battery specification and replacement method for the exact hardware revision. Incorrect handling may affect backed-up data or controller maintenance status.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is an SDHC card suitable for every maintenance or data-transfer task?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot automatically. The specified external media interface supports SDHC cards from 4 GB to 32 GB, Class 10. Before using a card, confirm its compatibility, formatting requirements, and intended function in the FCN system manual. Do not assume that any SD card or file system will be accepted.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What information should buyers provide when sourcing an NFCP502-W05 replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the complete model number, existing module nameplate information, FCN system configuration, and photographs of the front panel and connectors where possible. Also confirm whether the application requires the extended-function W configuration and the basic type without explosion protection. These checks help reduce ordering errors caused by similar-looking CPU module variants.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":68158608900278,"sku":"NFCP502-W05","price":152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/NFCP502-W05-1.jpg?v=1795594809","url":"https:\/\/www.plcsparehub.com\/products\/nfcp502-w05-yokogawa-cpu-module-fcn-ethernet-control-solution","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}