{"product_id":"mtl5024-mtl5000-series-solenoid-driver-is-alarm-control","title":"MTL5024 MTL5000 Series Solenoid Driver IS Alarm Control","description":"\u003ch3\u003e\u003cstrong\u003eMTL5024 Solenoid and Alarm Driver – Hazardous-Area Switching Interface\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1a73e8;\"\u003eMTL5024\u003c\/span\u003e\u003c\/strong\u003e is a single-channel, powered switching interface within the MTL5000 series. It controls hazardous-area on\/off devices using a volt-free contact or logic signal from a safe-area controller. Unlike an analog output interface, this module operates as a discrete load driver. It supplies a current-limited output for compatible solenoids, alarms, LEDs, and other low-power field devices. A base-mounted phase reversal switch changes the relationship between the safe-area input and hazardous-area output. Engineers can select the required switching behavior without changing the controller's basic logic signal. The module supports suitable intrinsically safe loads and non-energy-storing simple apparatus. Its application requires verification of the field device's certification, electrical characteristics, and installation conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAt a Glance: Switching and Load Control\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMTL5024 Solenoid\/Alarm Driver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMTL5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne switching channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVolt-free contact, open-collector transistor, or compatible logic signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent-limited hazardous-area switching output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 25 V; minimum 12.85 V at 45 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–35 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable normal or reversed phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen power LED and yellow status LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMTL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #1a73e8;\"\u003eMTL5024\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid and alarm driver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe-Area Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch contact, open-collector transistor, or logic drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ON Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBelow 1.4 V, or closed contact, with normal phase selected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput OFF Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbove 4.5 V, or open contact, with normal phase selected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReversed Phase Behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInverts the stated input-to-output switching relationship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.85 V at 45 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–35 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Supply Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA at 24 V; 120 mA at 20 V; 75 mA at 35 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Power Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 W with a typical solenoid, output ON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorst-Case Power Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Parameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUo = 25 V; equivalent resistance = 170 Ω; Io = 147 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Working Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUm = 250 V RMS or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecified Hazardous-Area Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZone 0, IIC, T4–T6, subject to suitable certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNorth American Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDivision 1, Group A, subject to applicable approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe source specifications do not provide a full temperature range, switching frequency, response time, or ingress protection rating. Confirm these details against the applicable manufacturer's documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Logic and Phase Selection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eMTL5024\u003c\/strong\u003e accepts several safe-area control methods. Its phase switch determines whether the output follows or reverses the input state.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal phase:\u003c\/strong\u003e A closed contact or input below 1.4 V turns the output ON.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal phase:\u003c\/strong\u003e An open contact or input above 4.5 V turns the output OFF.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReverse phase:\u003c\/strong\u003e The output responds with the opposite state for the corresponding input condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic interface:\u003c\/strong\u003e Compatible open-collector and logic signals can control the channel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe supplied thresholds define clear ON and OFF conditions. Do not assume every voltage between 1.4 V and 4.5 V represents a guaranteed state. Check the manufacturer's complete input specification when designing the control circuit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTerminal Layout and Wiring Reference\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUse the following terminal assignments as a preliminary wiring reference. Confirm the physical terminal markings and manufacturer's wiring diagram before connecting equipment.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eHazardous-area output negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eHazardous-area output positive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eEarth leakage detection connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003eSafe-area control negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eSafe-area control positive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003eDC supply negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003eDC supply positive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEquipment and Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module suits low-power discrete devices that meet its output and hazardous-area requirements. \u003clist\u003e\n\u003clist-item\u003e\u003cstrong\u003ePneumatic solenoid valves\u003c\/strong\u003e\n\nControls compatible valve coils for pneumatic actuators, process isolation, and instrument air switching.\u003c\/list-item\u003e\n\u003clist-item\u003e\u003cstrong\u003eHazardous-area alarms\u003c\/strong\u003e\n\nDrives approved low-power annunciators or alarm devices when their electrical demands fit the interface.\u003c\/list-item\u003e\n\u003clist-item\u003e\u003cstrong\u003eIndicator LEDs\u003c\/strong\u003e\n\nSwitches suitable field indicators for equipment status, permissive conditions, or local signaling.\u003c\/list-item\u003e\n\u003clist-item\u003e\u003cstrong\u003eProcess shutdown interfaces\u003c\/strong\u003e\n\nSupports discrete commands to suitable field loads within a properly engineered safety system.\u003c\/list-item\u003e\n\u003clist-item\u003e\u003cstrong\u003eOil and gas instrumentation\u003c\/strong\u003e\n\nInterfaces safe-area control logic with compatible field devices in classified process areas.\u003c\/list-item\u003e\n\u003clist-item\u003e\u003cstrong\u003eChemical and petrochemical plants\u003c\/strong\u003e\n\nProvides switching for approved low-power devices near classified process equipment.\u003c\/list-item\u003e\n\u003c\/list\u003e \u003cstrong\u003eApplication boundary:\u003c\/strong\u003e The MTL5024 is a low-power driver. Do not assume it can directly operate high-current actuators, general-purpose lamps, or unverified inductive loads.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Commissioning Workflow\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the field load.\u003c\/strong\u003e Check its operating current, voltage, coil characteristics, and hazardous-area certification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the supply.\u003c\/strong\u003e Maintain the specified 20–35 V DC supply range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the control signal.\u003c\/strong\u003e Confirm the controller provides a compatible contact or logic output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelect the phase.\u003c\/strong\u003e Set the base switch to match the intended control sequence.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview terminal wiring.\u003c\/strong\u003e Verify supply, input, output, and earth leakage detection connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest both states.\u003c\/strong\u003e Confirm that the field load switches ON and OFF as the controller commands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the indicators.\u003c\/strong\u003e Observe the green power LED and yellow status LED during functional tests.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecord the results.\u003c\/strong\u003e Document the phase setting, field-device response, and measured operating values.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eIsolate power before wiring or servicing. Follow site hazardous-area procedures and the manufacturer's installation instructions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eField Diagnostics and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe MTL5024 provides useful diagnostic checkpoints through its input logic, output behavior, current limit, and indicators. These checks help engineers narrow down field faults.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eObserved Condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Investigation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGreen power LED remains off\u003c\/td\u003e\n\u003ctd\u003eMeasure the DC supply and inspect supply polarity and terminal connections.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController changes state, but the load does not\u003c\/td\u003e\n\u003ctd\u003eVerify the phase switch, input thresholds, field wiring, and load compatibility.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput activates with the opposite command\u003c\/td\u003e\n\u003ctd\u003eCheck whether reverse phase is selected and compare it with the control logic.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolenoid operates intermittently\u003c\/td\u003e\n\u003ctd\u003eMeasure supply stability and check the load's current demand against the 45 mA limit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput remains inactive despite valid input\u003c\/td\u003e\n\u003ctd\u003eCheck the field circuit, terminal connections, load condition, and module status indication.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField device behaves unexpectedly after replacement\u003c\/td\u003e\n\u003ctd\u003eReconfirm coil specifications, certification, polarity, and the required switching phase.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal PLC Spare HUB Review\u003c\/strong\u003e A common commissioning issue occurs when a replacement driver uses a different phase setting from the original installation. The controller may issue the correct command, yet the field valve responds in reverse. For example, a normally de-energized process valve may energize when the controller output drops. Before changing PLC logic, check the MTL5024 phase switch and verify the intended safe state. Engineers should also distinguish a control fault from a load mismatch. A coil requiring more than the driver's current limit may fail to operate reliably. Confirm the device's actual electrical demand before replacing the interface.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility and Safe Selection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eChoose the MTL5024 only after checking the complete control and field circuit.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl-system output:\u003c\/strong\u003e Verify contact, open-collector, or logic compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-device demand:\u003c\/strong\u003e Confirm the required operating current does not exceed the 45 mA limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput voltage:\u003c\/strong\u003e Ensure the field load operates within the specified voltage capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching logic:\u003c\/strong\u003e Confirm normal or reverse phase matches the intended sequence.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous-area approval:\u003c\/strong\u003e Check the field device certification and installation conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem replacement:\u003c\/strong\u003e Compare terminal assignments, supply requirements, mounting arrangements, and applicable safety parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe safety parameters listed here do not replace the full certification documents. Verify the approved entity parameters and conditions for the complete intrinsically safe circuit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty, Packaging, and Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months, subject to the seller's written warranty terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e One MTL5024 module, subject to the confirmed order configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping carriers:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder verification:\u003c\/strong\u003e Confirm model, quantity, stock status, and shipping arrangements before payment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Global PLC Spare HUB for a quotation, product availability, and assistance verifying application compatibility.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How can engineers determine whether a solenoid is suitable for this driver?\u003c\/strong\u003e Check the coil's rated voltage, steady-state current, and operating requirements. Confirm that its demand fits the driver's current limit and output voltage. Also verify the coil's hazardous-area approval.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What should the phase switch setting represent in a shutdown application?\u003c\/strong\u003e It should match the required control sequence and defined safe state. Engineers must assess the entire shutdown circuit rather than choosing a phase based only on normal operating behavior.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can a standard PLC transistor output control the MTL5024?\u003c\/strong\u003e The specification supports compatible open-collector and logic signals. Verify the PLC output voltage, polarity, and switching characteristics against the interface input requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Why should engineers test the actual field load instead of relying only on an unloaded output measurement?\u003c\/strong\u003e A load can draw more current than the interface supports or require a different operating voltage. Testing under the intended load reveals problems that an unloaded voltage check may miss.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What information should buyers provide when choosing an equivalent driver?\u003c\/strong\u003e Provide the original part number, control-output type, field-load specifications, required phase behavior, supply voltage, terminal arrangement, and hazardous-area classification. These details support a safer compatibility assessment.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/MTL5024.png?v=1792723296\" alt=\"\"\u003e\u003c\/p\u003e","brand":"MTL","offers":[{"title":"Default Title","offer_id":45014020587702,"sku":"MTL5024","price":144.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/MTL5024_1.jpg?v=1792723296","url":"https:\/\/www.plcsparehub.com\/products\/mtl5024-mtl5000-series-solenoid-driver-is-alarm-control","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}