{"product_id":"mtl5011b-mtl5000-series-namur-input-relay-control-module","title":"MTL5011B MTL5000 Series NAMUR Input Relay Control Module","description":"\u003ch3\u003e\u003cb\u003eProduct Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #008000;\"\u003eMTL5011B\u003c\/strong\u003e is an intrinsically safe switch amplifier from the MTL5000 series. It monitors a hazardous-area switch or NAMUR proximity detector. Its relay output controls a load in the safe area. The module supports selectable phase reversal and line fault detection (LFD). Engineers can configure the output response to match the sensor's switching logic. The LFD function identifies open and short circuits in the field wiring. A detected line fault de-energizes the relay. The \u003cstrong style=\"color: #008000;\"\u003eMTL5011B\u003c\/strong\u003e suits industrial systems that require reliable switching, electrical isolation, and clear fault indication.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eMTL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #008000;\"\u003eMTL5011B\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSeries\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eMTL5000 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eIntrinsically Safe Switch Amplifier \/ Relay Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eNumber of Channels\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eInput Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eNAMUR proximity detector or compatible switch input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eInput Standard\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eNAMUR \/ DIN 19234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSensor Supply\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e7–9 V through a 1 kΩ ±10% source resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSafe-Area Output\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eOne single-pole changeover relay (SPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePhase Reversal\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eUser-selectable through switches on the top of the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eLine Fault Detection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eUser-selectable; detects open and short field circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Response Time\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRelay Contact Rating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V AC, 2 A, cos φ \u0026gt; 0.7; 40 V DC, 2 A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Current Consumption\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e40 mA at 20 V; 35 mA at 24 V; 25 mA at 35 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Power Dissipation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.75 W at 24 V; 0.8 W at 35 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V AC or DC between supply, hazardous-area circuits, and relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eGreen LED\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePower indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eYellow LED\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel status; illuminates when outputs energize\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRed LED\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eLine fault indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOperating Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eConfirm the permitted ambient range in the applicable manufacturer's common specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProtection Parameters\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5 V, 800 Ω, 14 mA; Um = 250 V RMS or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eEngineering note:\u003c\/b\u003e The supplied specifications do not state measurement range, frequency response, sensitivity, linearity, resolution, or environmental ratings. These parameters do not define this switching interface's primary function. Confirm installation limits against the applicable manufacturer's documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eInput Switching Characteristics\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #008000;\"\u003eMTL5011B\u003c\/strong\u003e evaluates the sensor current or resistance. The selected phase determines the relay's response.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eNormal phase:\u003c\/b\u003e The output energizes when input current exceeds 2.1 mA or input resistance falls below 2 kΩ.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNormal phase:\u003c\/b\u003e The output de-energizes when input current falls below 1.2 mA or input resistance exceeds 10 kΩ.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eReverse phase:\u003c\/b\u003e The relay response reverses for the corresponding input states.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTypical hysteresis:\u003c\/b\u003e 200 μA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eLine Fault Detection and Diagnostics\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe LFD function helps technicians distinguish wiring faults from normal sensor switching.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDiagnostic Condition\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eDetection Threshold\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit alarm activates\u003c\/td\u003e\n\u003ctd\u003eInput current below 100 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit alarm clears\u003c\/td\u003e\n\u003ctd\u003eInput current above 250 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit alarm activates\u003c\/td\u003e\n\u003ctd\u003eInput resistance below 100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit alarm clears\u003c\/td\u003e\n\u003ctd\u003eInput resistance above 360 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay response to detected fault\u003c\/td\u003e\n\u003ctd\u003eRelay de-energizes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault indication\u003c\/td\u003e\n\u003ctd\u003eRed LED illuminates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eContact input requirement:\u003c\/b\u003e Fit a 500 Ω to 1 kΩ resistor in series with the switch. Fit a 20 kΩ to 25 kΩ resistor in parallel with the switch. These resistors support line fault monitoring for contact inputs.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTerminal Configuration\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTerminal\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eInput negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eInput positive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eEarth leakage detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eRelay normally closed (NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003eRelay common (COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eRelay normally open (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003ePower supply negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003ePower supply positive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eHazardous-Area Compatibility and Safety\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #008000;\"\u003eMTL5011B\u003c\/strong\u003e supports specified hazardous-area switching applications when the complete installation meets applicable certification requirements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eSwitch location:\u003c\/b\u003e Zone 0, IIC, T6; Class I, Division 1, Group A, as specified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProximity detector location:\u003c\/b\u003e Zone 0, IIC, T4–T6, when the detector has suitable certification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInput compatibility:\u003c\/b\u003e NAMUR-compatible proximity detectors conforming to DIN 19234.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRelay interface:\u003c\/b\u003e Provides changeover contacts for safe-area control circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eElectrical isolation:\u003c\/b\u003e Separates the supply, hazardous-area input, and relay output circuits to the stated rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eImportant:\u003c\/b\u003e Verify the exact certification markings, control drawing, entity parameters, installation method, and local hazardous-area requirements before commissioning. The listed protection parameters alone do not establish approval for every installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eInstallation Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the model number and inspect the unit before installation.\u003c\/li\u003e\n\u003cli\u003eCheck the supply voltage against the manufacturer's common specification.\u003c\/li\u003e\n\u003cli\u003eConnect the sensor to terminals 1 and 2 with correct polarity.\u003c\/li\u003e\n\u003cli\u003eConnect the relay circuit to terminals 10, 11, and 12 as required.\u003c\/li\u003e\n\u003cli\u003eConnect the supply to terminals 13 and 14 with correct polarity.\u003c\/li\u003e\n\u003cli\u003eConfigure phase reversal and LFD using the top-mounted switches.\u003c\/li\u003e\n\u003cli\u003eInstall the required resistors when using LFD with a contact input.\u003c\/li\u003e\n\u003cli\u003eVerify wiring, earthing, isolation, and hazardous-area compliance before energizing.\u003c\/li\u003e\n\u003cli\u003eTest normal switching and fault responses before returning the system to service.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eSuppress reactive relay loads adequately. Follow the manufacturer's wiring diagrams and approved installation instructions.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eCommissioning and Maintenance\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003ePower check:\u003c\/b\u003e Confirm that the green LED illuminates after energizing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInput check:\u003c\/b\u003e Operate the field sensor and observe the yellow channel LED.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRelay check:\u003c\/b\u003e Verify the NO and NC contact states with a suitable test instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLFD check:\u003c\/b\u003e Use an approved test procedure to verify open- and short-circuit detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConfiguration check:\u003c\/b\u003e Confirm the selected phase matches the required alarm logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRoutine inspection:\u003c\/b\u003e Check terminals, wiring condition, and relay operation during scheduled maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eField troubleshooting example:\u003c\/b\u003e A proximity detector changes state, but the control system receives no signal. First, check the green power LED. Then inspect the yellow status LED and red LFD indicator. If the red LED illuminates, isolate the circuit safely and inspect the field wiring for an open circuit or short circuit. Confirm the phase selection before replacing components.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTypical Industrial Applications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eProcess plants:\u003c\/b\u003e Transfer switch states from hazardous process areas to safe-area control systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOil and gas:\u003c\/b\u003e Interface compatible proximity detectors with relay-based monitoring circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eChemical processing:\u003c\/b\u003e Monitor equipment positions and discrete process conditions in classified areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRotating machinery:\u003c\/b\u003e Relay compatible position or proximity signals to alarms and interlocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTank farms:\u003c\/b\u003e Transfer discrete switch signals from suitable hazardous-area equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIndustrial alarm systems:\u003c\/b\u003e Use selectable phase reversal to match required alarm logic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eCompatibility and Selection Guidance\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #008000;\"\u003eMTL5011B\u003c\/strong\u003e is suitable for compatible NAMUR sensors and supported contact inputs. Confirm the following points before ordering:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSensor output type and NAMUR compatibility.\u003c\/li\u003e\n\u003cli\u003eHazardous-area classification and sensor certification.\u003c\/li\u003e\n\u003cli\u003eRequired relay contact configuration and load rating.\u003c\/li\u003e\n\u003cli\u003ePower supply voltage and available control panel space.\u003c\/li\u003e\n\u003cli\u003eWhether line fault detection is necessary.\u003c\/li\u003e\n\u003cli\u003eWhether contact-input resistors are required for LFD operation.\u003c\/li\u003e\n\u003cli\u003eRequired switching logic and alarm state during a fault.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not assume compatibility with analog transmitters or high-speed pulse measurement. The \u003cstrong style=\"color: #008000;\"\u003eMTL5011B\u003c\/strong\u003e is a discrete switching interface, not a general-purpose analog signal conditioner.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003ePackaging, Shipping, and Warranty\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eProduct:\u003c\/b\u003e MTL5011B switch amplifier relay interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePackaging:\u003c\/b\u003e Protective packaging suitable for transport.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIncluded items:\u003c\/b\u003e One module. Accessories and documentation depend on the confirmed supply package.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWarranty:\u003c\/b\u003e 12-month warranty, subject to the seller's applicable terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eShipping carriers:\u003c\/b\u003e FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDispatch:\u003c\/b\u003e Shipping within 24–48 hours, subject to stock confirmation and order processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOrder support:\u003c\/b\u003e Contact Global PLC Spare HUB to confirm availability, condition, packaging, and delivery options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eIn field applications, a relay interface must do more than transfer a sensor state. It must also provide predictable switching logic and useful fault information. Consider a hazardous-area proximity detector that monitors a valve position. If the field cable breaks, the receiving control system may otherwise interpret the signal incorrectly. The \u003cstrong style=\"color: #008000;\"\u003eMTL5011B\u003c\/strong\u003e can identify supported open- and short-circuit conditions when LFD is configured correctly. Its relay then de-energizes, while the red LED indicates the detected fault. During commissioning, engineers should test both sensor states and simulate approved wiring faults. They should also confirm the selected phase and the control system's response to relay de-energization. This process helps identify wiring and configuration errors before normal operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ1: What does the MTL5011B do?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #008000;\"\u003eMTL5011B\u003c\/strong\u003e interfaces a compatible hazardous-area switch or proximity detector with a safe-area relay circuit. It also provides selectable phase reversal and line fault detection.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ2: Can the MTL5011B detect a broken sensor cable?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Its selectable LFD function detects specified open-circuit and short-circuit conditions. Correct configuration and suitable field wiring are essential. Contact inputs also require the specified series and parallel resistors.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ3: Why does the relay de-energize during a line fault?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe module de-energizes the relay when it detects a supported line fault. This response can help the control system identify an abnormal field circuit. Engineers must verify the resulting alarm logic during commissioning.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ4: What should engineers check before replacing a faulty MTL5011B?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the supply voltage, sensor wiring, terminal polarity, LED indications, phase selection, and relay contacts. Test for open or short circuits when LFD is enabled. Replace the module only after external wiring and configuration checks.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ5: How should buyers select the correct replacement or spare module?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eMatch the complete \u003cstrong style=\"color: #008000;\"\u003eMTL5011B\u003c\/strong\u003e model number and verify the input type, hazardous-area requirements, relay rating, supply voltage, and LFD needs. Confirm terminal compatibility and certification requirements with the existing system. Contact Global PLC Spare HUB with the nameplate details and application requirements before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eContact Global PLC Spare HUB\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eNeed the \u003cstrong style=\"color: #008000;\"\u003eMTL5011B\u003c\/strong\u003e for maintenance, replacement, or project inventory? Contact Global PLC Spare HUB for pricing, availability, warranty terms, and shipping options. Our team can help verify the model against your application requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/MTL5011B_5e1a51fa-74a7-4d62-b54c-cbf82493a682.png?v=1792983136\" alt=\"\"\u003e\u003c\/p\u003e","brand":"MTL","offers":[{"title":"Default Title","offer_id":45014020686006,"sku":"MTL5011B","price":149.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/MTL5011B_1.jpg?v=1792983112","url":"https:\/\/www.plcsparehub.com\/products\/mtl5011b-mtl5000-series-namur-input-relay-control-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}