{"product_id":"mtl4014-mtl-intrinsically-safe-switch-interface-module","title":"MTL4014 MTL Intrinsically Safe Switch Interface Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Introduction\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0070c0;\"\u003e\u003cstrong\u003eMTL4014\u003c\/strong\u003e\u003c\/span\u003e is an intrinsically safe switch and proximity detector interface manufactured by \u003cstrong\u003eMTL\u003c\/strong\u003e. It connects hazardous-area sensors to safe-area control circuits through reed relay outputs.\u003c\/p\u003e\n\u003cp\u003eThe module transfers switching signals from proximity detectors or mechanical switches. It also provides independent line fault indication through a separate reed relay.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eMTL4014\u003c\/strong\u003e supports NAMUR and DIN 19234 proximity detector standards. Its line fault detection (LFD) function identifies broken and shorted sensor wiring. Engineers can also connect an \u003cstrong\u003eMTL4220\u003c\/strong\u003e earth leakage detector for additional earth fault monitoring.\u003c\/p\u003e\n\u003cp\u003eThis interface suits industrial control systems that require reliable signal transfer between hazardous and safe areas. Typical applications include process instrumentation, plant safety systems, and industrial equipment monitoring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eMTL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMTL4014\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIntrinsically Safe Switch \/ Proximity Detector Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eReed Relay, Single-Pole On\/Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Compatibility\u003c\/td\u003e\n\u003ctd\u003eNAMUR Proximity Detectors and Mechanical Switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e7.0–9.0 V DC from 1 kΩ nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Closed Threshold\u003c\/td\u003e\n\u003ctd\u003eInput above 2.1 mA; resistance below 2 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Open Threshold\u003c\/td\u003e\n\u003ctd\u003eInput below 1.2 mA; resistance above 10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Hysteresis\u003c\/td\u003e\n\u003ctd\u003e200 µA; 650 Ω nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Fault Detection\u003c\/td\u003e\n\u003ctd\u003eBroken line below 50 µA; short circuit below 100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Response Time\u003c\/td\u003e\n\u003ctd\u003e2 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Rating\u003c\/td\u003e\n\u003ctd\u003e10 W, 0.5 A, 35 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Life\u003c\/td\u003e\n\u003ctd\u003e10⁷ operations at maximum load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e20–35 V DC operating conditions specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e45 mA at 24 V DC; 50 mA at 20 V DC; 36 mA at 35 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e1.1 W at 24 V; 1.3 W at 35 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003e250 V AC between safe and hazardous-area circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Description\u003c\/td\u003e\n\u003ctd\u003e10.5 V, 800 Ω, 14 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFM Entity Parameters\u003c\/td\u003e\n\u003ctd\u003eVoc: 10.5 V DC; Isc: 14 mA; Ca: 2.4 µF; La: 165 mH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous-Area Switch Location\u003c\/td\u003e\n\u003ctd\u003eZone 0, IIC, T6; Division 1, Group A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximity Detector Location\u003c\/td\u003e\n\u003ctd\u003eZone 0, IIC, T4–T6 with suitable certification; Division 1, Group A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Functional Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous-Area Signal Interface:\u003c\/strong\u003e Transfers sensor switching signals to safe-area equipment through reed relay contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Line Fault Detection:\u003c\/strong\u003e Detects open-circuit and short-circuit conditions in the sensor wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndependent Fault Indication:\u003c\/strong\u003e Provides a separate reed relay for line fault reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Earth Fault Monitoring:\u003c\/strong\u003e Supports connection to an MTL4220 earth leakage detector through terminal 6.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Switching:\u003c\/strong\u003e Provides a maximum relay response time of 2 ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e Maintains 250 V AC isolation between safe-area and hazardous-area circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eLED Status Indication\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLED Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIndication\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmber\u003c\/td\u003e\n\u003ctd\u003eInput Status\u003c\/td\u003e\n\u003ctd\u003eON when the output circuit closes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003eLine Fault\u003c\/td\u003e\n\u003ctd\u003eON when the module detects a line fault.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003ctd\u003ePower Status\u003c\/td\u003e\n\u003ctd\u003eIndicates module power.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTerminal Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eInput Negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eInput Positive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eOptional connection to MTL4220 earth leakage detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7, 8\u003c\/td\u003e\n\u003ctd\u003eChannel Relay Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10, 11\u003c\/td\u003e\n\u003ctd\u003eLine Fault Relay Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003ePower Supply Negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003ePower Supply Positive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eMTL4014\u003c\/strong\u003e performs two important functions in hazardous-area signal interfaces. It transfers sensor states and independently reports wiring faults.\u003c\/p\u003e\n\u003cp\u003eEngineers should pay particular attention to the LFD thresholds during commissioning. The module identifies broken wiring below 50 µA and short circuits below 100 Ω.\u003c\/p\u003e\n\u003cp\u003eThese thresholds help maintenance teams distinguish wiring failures from normal sensor switching conditions. However, the module does not replace field cable inspection or sensor diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSwitch Sensor Configuration:\u003c\/strong\u003e Mechanical switches require additional resistors. Engineers must install these resistors according to the manufacturer's circuit diagram. Incorrect resistor selection can affect switching thresholds and line fault detection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProximity Detector Configuration:\u003c\/strong\u003e Select a NAMUR-compatible detector that meets the module's electrical requirements. Verify hazardous-area certification and temperature classification before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEarth Fault Monitoring:\u003c\/strong\u003e Engineers can connect an MTL4220 to terminal 6. This arrangement provides earth fault detection on either sensor line. The interface continues operating when it reports an earth fault.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Load Management:\u003c\/strong\u003e The relay contacts support a maximum rating of 10 W, 0.5 A, and 35 V DC. Suppress reactive loads adequately to protect the contacts and maintain switching reliability.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the Model:\u003c\/strong\u003e Confirm the MTL4014 model and application requirements before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the Sensor:\u003c\/strong\u003e Verify NAMUR compatibility or the required switch resistor arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the Wiring:\u003c\/strong\u003e Check cable polarity, terminal assignments, and insulation condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect the Sensor:\u003c\/strong\u003e Connect the sensor negative and positive conductors to terminals 1 and 2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect the Relay:\u003c\/strong\u003e Wire the channel output through terminals 7 and 8.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect Fault Signalling:\u003c\/strong\u003e Use terminals 10 and 11 for independent line fault monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect the Power:\u003c\/strong\u003e Apply the specified DC supply to terminals 13 and 14.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigure Earth Monitoring:\u003c\/strong\u003e Connect an MTL4220 to terminal 6 when the application requires earth fault detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify Operation:\u003c\/strong\u003e Check the LEDs and test normal switching and fault indications.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eAlways isolate the power supply before changing field wiring. Follow the approved installation drawings and hazardous-area procedures. Confirm entity compatibility before connecting equipment in an intrinsically safe circuit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eProper commissioning helps engineers identify wiring and configuration problems before system operation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Verification:\u003c\/strong\u003e Measure the sensor loop current and confirm the expected switching thresholds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLFD Testing:\u003c\/strong\u003e Simulate approved open-circuit and short-circuit conditions to verify fault reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Testing:\u003c\/strong\u003e Check channel relay and line fault relay contact operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Inspection:\u003c\/strong\u003e Confirm amber, red, and green indicators respond correctly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Inspection:\u003c\/strong\u003e Verify supply voltage and compare current consumption with specified values.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeriodic Maintenance:\u003c\/strong\u003e Inspect terminal tightness, cable insulation, and field connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not bypass line fault detection during routine troubleshooting. The MTL4014 specification states that LFD cannot be disabled.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility and Selection Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBefore selecting the \u003cstrong\u003eMTL4014\u003c\/strong\u003e, engineers should evaluate the following conditions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type:\u003c\/strong\u003e Choose a compatible NAMUR proximity detector or a mechanical switch with the specified resistors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous-Area Classification:\u003c\/strong\u003e Match the sensor certification with the installation zone, gas group, and temperature class.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Parameters:\u003c\/strong\u003e Check sensor current, loop resistance, supply voltage, and intrinsically safe entity parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Requirements:\u003c\/strong\u003e Ensure the connected load stays within the contact voltage, current, and power ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Monitoring:\u003c\/strong\u003e Confirm the control system can receive the separate line fault relay signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Fault Protection:\u003c\/strong\u003e Consider the optional MTL4220 when the application requires additional earth leakage monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e The MTL4014 is a single-channel interface. Applications requiring multiple independent sensor channels need additional compatible interfaces.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCertification and Safety Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe available technical specification identifies the following hazardous-area application parameters:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSwitch installation: Zone 0, IIC, T6.\u003c\/li\u003e\n\u003cli\u003eProximity detector installation: Zone 0, IIC, T4–T6, subject to suitable certification.\u003c\/li\u003e\n\u003cli\u003eNorth American hazardous location classification: Division 1, Group A.\u003c\/li\u003e\n\u003cli\u003eFM entity parameters: Voc 10.5 V DC, Isc 14 mA, Ca 2.4 µF, and La 165 mH.\u003c\/li\u003e\n\u003cli\u003eSafety description: 10.5 V, 800 Ω, and 14 mA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese values describe the supplied technical data. They do not independently establish every regional product approval. Confirm the applicable certificates and installation conditions before deployment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging and Delivery Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e MTL4014 Switch \/ Proximity Detector Interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e MTL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e According to the purchase order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessories:\u003c\/strong\u003e Confirm separately according to the ordered configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocumentation:\u003c\/strong\u003e Request applicable technical documentation and wiring information when ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePackage contents may vary with the order. Please confirm the included accessories and documentation with our sales team before purchasing.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the primary function of the MTL4014?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MTL4014 transfers switching signals from hazardous-area proximity detectors or switches to safe-area circuits. It also provides separate line fault indication through a reed relay.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can the MTL4014 work with mechanical switches?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Mechanical switches require additional resistors to support line fault detection. Follow the manufacturer's circuit diagram when selecting and installing these resistors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What should engineers check when the red LED illuminates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirst, inspect the sensor cable for open circuits and short circuits. Check terminal connections and measure loop conditions. The module reports broken lines below 50 µA and shorted lines below 100 Ω.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can engineers disable the line fault detection function?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The MTL4014 specification states that line fault detection cannot be disabled. Engineers should account for this function when designing sensor wiring and troubleshooting procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: When should engineers select the MTL4220?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSelect the MTL4220 when the application requires additional earth leakage monitoring. Connect it to terminal 6 according to the manufacturer's wiring instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: What should engineers verify before replacing an existing interface?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck channel count, sensor compatibility, input thresholds, hazardous-area parameters, and relay contact ratings. Also verify terminal assignments and the existing control system wiring. Matching physical dimensions alone does not establish electrical compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ7: How should engineers select the correct MTL4014 configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart with the field sensor type and hazardous-area classification. Then verify the required relay outputs, line fault monitoring, supply voltage, and connected load. Request technical confirmation when the installation uses unusual sensor or cable arrangements.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/MTL4014_2.png?v=1793846756\" alt=\"\"\u003e\u003c\/p\u003e","brand":"MTL","offers":[{"title":"Default Title","offer_id":45013997781174,"sku":"MTL4014","price":151.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/MTL4014.jpg?v=1793846622","url":"https:\/\/www.plcsparehub.com\/products\/mtl4014-mtl-intrinsically-safe-switch-interface-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}