{"product_id":"midas-a-007-honeywell-midas-gas-detector-accessory-in-stock-express","title":"MIDAS-A-007 Honeywell Midas Gas Detector Accessory In-Stock Express","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eHoneywell Midas MIDAS-A-007\u003c\/span\u003e\u003c\/strong\u003e serves as an essential extractive sampling line component engineered for the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eMidas\u003c\/span\u003e\u003c\/strong\u003e gas detection platform.\u003c\/li\u003e\n\u003cli\u003eThis device supports continuous sample transport protocols from remote observation areas to the transmitter core.\u003c\/li\u003e\n\u003cli\u003eIt regulates internal pneumatics to ensure uncompromised flow monitoring across harsh industrial detection zones.\u003c\/li\u003e\n\u003cli\u003eBy stabilizing the sample delivery speed, it protects optical and electrochemical cartridges from unexpected localized pressure shocks.\u003c\/li\u003e\n\u003cli\u003eThe design enhances industrial life-safety architectures with highly uniform sampling reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eMIDAS-A-007\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eMidas\u003c\/span\u003e\u003c\/strong\u003e Gas Detection System\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eItem Type:\u003c\/strong\u003e Extractive Sample Transport Assembly \/ Accessory\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Operating Supply:\u003c\/strong\u003e 24 VDC (-15% to +10% tolerance boundary)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoE Network Input:\u003c\/strong\u003e 48 VDC Power over Ethernet (IEEE 802.3af compliant infrastructure)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Power draw:\u003c\/strong\u003e Toxic gas configurations require less than 4W power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Power Draw:\u003c\/strong\u003e Pyrolyzer-equipped configurations consume less than 12.95W maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegulated Transport Velocity:\u003c\/strong\u003e Nominally 500 mL per minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Tube Dimensions:\u003c\/strong\u003e 3.18mm ID x 6.35mm OD (0.125 x 0.25 inches)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExhaust Tube Dimensions:\u003c\/strong\u003e 4.76mm ID x 6.35mm OD (0.188 x 0.25 inches)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Line Run:\u003c\/strong\u003e Up to 30 meters (100 feet) using certified FEP tubing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Thermal Envelope:\u003c\/strong\u003e 0 to 40°C (32 to 104°F); reduced to 30°C max for pyrolyzer setups\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Rating:\u003c\/strong\u003e Classified for Indoor Pollution Degree 2 installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Area Analysis (MECE Matrix)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Draw:\u003c\/strong\u003e Maintains a stable 500 mL\/min extraction rate to eliminate transport lag over long sample runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Extension:\u003c\/strong\u003e Drives sample streams through FEP lines up to 100 feet without suffering significant transport pressure drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExhaust Handling:\u003c\/strong\u003e Directs sampled gases safely away through a wider 4.76mm ID exhaust pathway to prevent backpressure buildup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Power Pathing:\u003c\/strong\u003e Accepts traditional 24 VDC hardwired power lines or single-cable 48 VDC PoE network deployments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePyrolyzer Support:\u003c\/strong\u003e Accommodates high-temperature gas cracking power requirements up to 12.95W for specialized gas families.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit Isolation:\u003c\/strong\u003e Built to Overvoltage Category 1 standards to safeguard downstream analyzer electronics from spikes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual Telemetry:\u003c\/strong\u003e Interfaces directly with the 2.4-inch 16.7M color IPS panel for real-time monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Matrix:\u003c\/strong\u003e Bridges on-site hardware via three dry-contact relays rated up to 1.0A at 30VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Integration:\u003c\/strong\u003e Routes telemetry packets via Modbus\/TCP protocols over standard Ethernet physical layers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdvanced Subsystem Diagnostic Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Obstruction Monitoring:\u003c\/strong\u003e Detects inline kink or blockage events by tracking subtle transport pump motor deviations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Envelope Supervision:\u003c\/strong\u003e Monitors ambient shifts exceeding 40°C (or 30°C in pyrolyzer operations) to protect sensor calibration stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Loss Interlocking:\u003c\/strong\u003e Drops the fault relay contact immediately if Modbus\/TCP keep-alive packets experience communication timeouts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Mechanical Boundary Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTubing Specification:\u003c\/strong\u003e Always deploy high-purity Fluorinated Ethylene Propylene (FEP) tubing to prevent target gas absorption along the sample path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInline Filtration:\u003c\/strong\u003e Mount a particulate filter at the sample point to stop moisture and dust from entering the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eMIDAS-A-007\u003c\/span\u003e\u003c\/strong\u003e pneumatic core.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Footprint:\u003c\/strong\u003e Ensure your enclosure depth accommodates the total length of 148mm when the sensor cartridge is fully seated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem \u0026amp; Device Suitability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMidas\u003c\/strong\u003e Extractive Transmitters: Standard integration with baseline toxic, flammable, and oxygen gas detection loops.\u003c\/li\u003e\n\u003cli\u003ePyrolyzer Units: High-temperature sampling networks monitoring NF3 or alternative fluorinated gases.\u003c\/li\u003e\n\u003cli\u003eSemiconductor Cleanrooms: Remote multipoint atmospheric monitoring manifolds requiring fast sample refreshing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProcurement Selection \u0026amp; Engineering Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Compatibility Check:\u003c\/strong\u003e Match your tubing material directly to the chemical properties of your target gas to prevent inaccurate readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Budget Evaluation:\u003c\/strong\u003e When utilizing Power over Ethernet switches, verify that the port power budget can supply the 12.95W required for pyrolyzer modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistance Constraints:\u003c\/strong\u003e If your extraction distance exceeds 100 feet, you must specify an external booster pump assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eLogistics, Packaging \u0026amp; Warranty Framework\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Express Despatch:\u003c\/strong\u003e Fast, trackable global transport via FedEx, UPS, and DHL networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Window:\u003c\/strong\u003e Available stock units are processed and shipped within 24 to 48 hours of order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransit Preservation:\u003c\/strong\u003e Shipped in a custom-molded anti-static box designed to withstand standard industrial shipping transit shocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContractual Warranty:\u003c\/strong\u003e Includes a 12-month commercial warranty covering component failure and manufacturing anomalies from the delivery date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eHoneywell Midas MIDAS-A-007\u003c\/span\u003e\u003c\/strong\u003e represents a highly precise pneumatic transport design.\u003c\/li\u003e\n\u003cli\u003eField data indicates that incorrect sample line sizing often leads to pump failures or false flow alarms.\u003c\/li\u003e\n\u003cli\u003eFor best results, adhere strictly to the 3.18mm internal diameter specification for sample lines and use the wider 4.76mm tube for exhaust runs.\u003c\/li\u003e\n\u003cli\u003eWhen deploying these units in high-humidity cleanroom environments, installing a high-quality inline hydrophobic filter is critical to protect sensitive components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the maximum operating temperature reduced to 30°C when running a pyrolyzer module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe pyrolyzer module generates significant internal heat while cracking gases, which requires a lower ambient threshold to prevent thermal damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan standard polyurethane or PVC tubing be utilized for the extraction line?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, standard tubing can absorb reactive toxic gases or leach plasticizers, which reduces measurement accuracy and can degrade your sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the different internal diameters specified for the sample and exhaust lines?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe larger exhaust internal diameter reduces backpressure on the pump, which maintains a stable 500 mL\/min flow rate across the system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module react to a complete blockage or restriction in the remote sample line?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system detects the sudden drop in flow rate, changes the TFT display color, and trips the dedicated fault relay contact.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs an external power supply required when integrating the module into an active PoE network?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the module draws all required operating power directly through the standard RJ45 Ethernet connection when connected to a compliant PoE switch.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45219251880118,"sku":"MIDAS-A-007","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/MIDAS-A-007.jpg?v=1782379010","url":"https:\/\/www.plcsparehub.com\/products\/midas-a-007-honeywell-midas-gas-detector-accessory-in-stock-express","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}