{"product_id":"mdx61b0055-5a3-4-00-sew-inverter-drive-movidrive-3-phase","title":"MDX61B0055-5A3-4-00 SEW Inverter Drive | MOVIDRIVE 3-Phase","description":" \u003ch3\u003e\u003cstrong\u003eSEW MOVIDRIVE MDX61B0055-5A3-4-00 Inverter Drive\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #2E6DA4;\"\u003eMDX61B0055-5A3-4-00\u003c\/span\u003e\u003c\/strong\u003e is a SEW MOVIDRIVE inverter drive designed for variable-speed control of compatible three-phase motors. It supports a 380–500 V AC supply and a recommended motor power of 5.5 kW under constant-load conditions. Its four-quadrant configuration includes a brake chopper, making it a candidate for drive systems that require controlled deceleration and braking energy management.\u003c\/p\u003e\n\n\u003cp\u003eWith a rated output current of 12.5 A and an output rating of 8.7 kVA, this unit suits industrial motion applications where motor ratings, load characteristics, and braking requirements must align with the drive configuration. Confirm the complete part number and system requirements before replacing an installed unit.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e01 | Electrical and Mechanical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSEW-Eurodrive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMDX61B0055-5A3-4-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct series\u003c\/td\u003e\n\u003ctd\u003eMOVIDRIVE MDX61B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eInverter drive \/ variable-frequency drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended motor power\u003c\/td\u003e\n\u003ctd\u003e5.5 kW, constant-load application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e3 × 380–500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz, as provided in the product data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current\u003c\/td\u003e\n\u003ctd\u003e12.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power rating\u003c\/td\u003e\n\u003ctd\u003e8.7 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuadrant configuration\u003c\/td\u003e\n\u003ctd\u003e4Q, with brake chopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine-side radio interference suppression\u003c\/td\u003e\n\u003ctd\u003eClass C2, as specified in the supplied code description\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e2S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e105 × 335 × 294 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003e02 | Model and Suffix Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eUse the following breakdown to review the supplied ordering code. Verify the complete code against the drive nameplate and the applicable SEW documentation before ordering a replacement.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode segment\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003cth\u003eSelection relevance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMDX61\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries with options available for installation\u003c\/td\u003e\n\u003ctd\u003eIdentifies the drive family and its option-based configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVersion B\u003c\/td\u003e\n\u003ctd\u003eIdentifies the specified product version.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0055\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRecommended motor power: 5.5 kW\u003c\/td\u003e\n\u003ctd\u003eCheck the motor nameplate and actual load duty.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupply voltage: 380–500 V AC\u003c\/td\u003e\n\u003ctd\u003eMust match the site's three-phase supply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine-side radio interference suppression, class C2\u003c\/td\u003e\n\u003ctd\u003eCheck EMC requirements and installation conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-phase connection\u003c\/td\u003e\n\u003ctd\u003eConfirm the incoming supply arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour-quadrant operation with brake chopper\u003c\/td\u003e\n\u003ctd\u003eReview braking duty and any external braking components required by the application.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard type\u003c\/td\u003e\n\u003ctd\u003eConfirm any required options separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003e03 | Application Fit: Where This Drive Can Be Used\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe MDX61B0055-5A3-4-00 may suit industrial equipment that requires variable motor speed and controlled braking, provided the motor and load fall within the drive's ratings.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyor systems:\u003c\/strong\u003e Adjust belt speed to match production flow and reduce abrupt mechanical transitions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging machinery:\u003c\/strong\u003e Support speed adjustment for compatible feeding, conveying, and handling mechanisms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial-handling equipment:\u003c\/strong\u003e Apply variable-speed control where deceleration and stopping behavior affect throughput.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial process machinery:\u003c\/strong\u003e Regulate motor speed in compatible mixers, feeders, and auxiliary equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofit and maintenance projects:\u003c\/strong\u003e Replace a failed drive when the electrical ratings, configuration, control interface, and braking requirements match the existing installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eEngineering note:\u003c\/strong\u003e A four-quadrant designation and brake chopper do not by themselves confirm suitability for every regenerative or high-inertia load. Review the braking energy, duty cycle, stopping frequency, and required braking hardware before commissioning.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e04 | Diagnostics, Commissioning, and Troubleshooting\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eDrive-related faults can originate in the power supply, motor circuit, parameter settings, load mechanics, or braking system. A structured check helps distinguish a drive failure from an external equipment problem.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrive will not start:\u003c\/strong\u003e Verify the three-phase supply, enable and start commands, interlocks, and configured control source. Check the drive's displayed status or fault information using the available operator or diagnostic interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor overload or unexpected trips:\u003c\/strong\u003e Compare motor nameplate current with the configured motor data. Inspect mechanical binding, load changes, acceleration settings, and operating duty before replacing the inverter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExcessive deceleration faults:\u003c\/strong\u003e Review the stopping ramp and the application's braking energy. Confirm the brake chopper arrangement and any required braking resistor against the manufacturer's documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterference or unstable control:\u003c\/strong\u003e Inspect grounding, cable routing, shielding, and installation practices against the applicable EMC requirements. The C2 suppression designation does not eliminate the need for correct wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement commissioning:\u003c\/strong\u003e Record the existing parameter set and control wiring before removal. Verify motor data, command source, speed limits, ramp times, protective functions, and braking behavior before returning equipment to service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eAvailable diagnostic detail depends on the installed interface, software, parameter configuration, and system integration. This description does not assume a specific fault code, communication option, or onboard diagnostic feature that has not been confirmed for the supplied unit.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e05 | Global PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eFor a drive replacement, matching the 5.5 kW motor rating is only the first check. Field engineers should also compare the rated output current, supply range, control architecture, parameter settings, and braking arrangement. Two drives with similar power ratings may not provide a direct drop-in replacement when their option codes or application settings differ.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eMDX61B0055-5A3-4-00\u003c\/strong\u003e is worth evaluating for maintenance stock and compatible machine retrofits where a 380–500 V three-phase supply and a 5.5 kW motor application are specified. Before purchase, provide the full nameplate code, motor data, and existing drive configuration so the replacement can be checked against the actual operating conditions.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e06 | Compatibility and Selection Checklist\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eMatch the complete model code, including all suffixes, with the installed unit.\u003c\/li\u003e\n\u003cli\u003eConfirm that the available supply is three-phase 380–500 V AC.\u003c\/li\u003e\n\u003cli\u003eCheck motor rated current and load duty; do not select by kW alone.\u003c\/li\u003e\n\u003cli\u003eReview the brake chopper and braking requirements, especially for frequent stops or high-inertia loads.\u003c\/li\u003e\n\u003cli\u003eConfirm control wiring, installed options, parameter backup, and required interfaces before installation.\u003c\/li\u003e\n\u003cli\u003eCheck enclosure clearance, mounting dimensions, ventilation, and the panel's thermal conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003e07 | Warranty, Shipping, and Package Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty, subject to the seller's warranty terms and conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping methods:\u003c\/strong\u003e FedEx, UPS, or DHL, subject to destination and shipment arrangements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage contents:\u003c\/strong\u003e One MDX61B0055-5A3-4-00 inverter drive. Additional accessories are included only when explicitly listed in the quotation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBefore ordering:\u003c\/strong\u003e Request confirmation of the exact model code, unit condition, included items, and compatibility requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003e08 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: Is the MDX61B0055-5A3-4-00 suitable for every 5.5 kW motor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Compare the motor's rated current, voltage, operating duty, and overload requirements with the drive's specifications. A 5.5 kW motor rating alone does not establish compatibility.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What should be checked before replacing an existing MOVIDRIVE unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Match the full ordering code and compare the supply, output current, control interfaces, installed options, and braking arrangement. Where possible, back up the original parameters and document terminal wiring before removal.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Does the built-in brake chopper mean an external braking resistor is unnecessary?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Not necessarily. The chopper supports braking-energy management, but the required resistor or other braking arrangement depends on the application and the manufacturer's configuration rules. Confirm stopping frequency, inertia, and resistor requirements before commissioning.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: What information helps diagnose repeated overcurrent or drive-trip problems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Record the displayed fault information, operating conditions, motor current, acceleration and deceleration settings, and whether the problem occurs during startup or under load. Inspect the motor circuit and mechanical load before concluding that the inverter itself has failed.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: What information should I provide when requesting a replacement quotation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Provide the complete model code, a clear nameplate photo, motor nameplate data, supply voltage, control-interface requirements, and braking details. These details help assess electrical compatibility and identify differences between the requested unit and the installed drive.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":67740817457334,"sku":"MDX61B0055-5A3-4-00","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/MDX61B0055-5A3-4-00-1.jpg?v=1792741956","url":"https:\/\/www.plcsparehub.com\/products\/mdx61b0055-5a3-4-00-sew-inverter-drive-movidrive-3-phase","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}