{"product_id":"mdx61b0022-5a3-4-00-sew-movidrive-b-inverter-drive","title":"MDX61B0022-5A3-4-00 SEW MOVIDRIVE B Inverter Drive","description":"\u003ch3\u003e\u003cstrong\u003eMDX61B0022-5A3-4-00 | SEW MOVIDRIVE B Inverter Drive\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSEW MDX61B0022-5A3-4-00\u003c\/strong\u003e is a variable-frequency inverter drive from the MOVIDRIVE B series, specified for three-phase AC power systems and motor applications rated at 2.2 kW (3 HP). Its configuration includes a four-quadrant designation with a brake chopper and a C2 radio-interference suppression specification.\u003c\/p\u003e\n\u003cp\u003eFor drive engineers, selection should start with the motor nameplate, supply voltage, rated output current, load profile, braking requirements, and cabinet installation constraints. The model code also identifies important configuration details that should be matched when replacing an installed drive.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Drive Specification Matrix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSEW-EURODRIVE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #1677c8;\"\u003e\u003cstrong\u003eMDX61B0022-5A3-4-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOVIDRIVE B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInverter drive \/ variable-frequency drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended motor power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 kW \/ 3 HP, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-phase, 380–500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A, as supplied; verify against the applicable rating plate and technical manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 A, as supplied; confirm the rated current for the intended duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–599 Hz, as supplied; confirm the permitted range for the configured drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuadrant \/ braking configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4Q designation with brake chopper, according to the supplied model data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC-related configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC2 radio-interference suppression on the line side, according to the supplied ordering data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSize 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 × 314 × 234 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data note:\u003c\/strong\u003e The source also lists “0-VIN output,” but does not define the term clearly. It is not treated here as a confirmed output-voltage specification. Check the original nameplate or SEW-EURODRIVE documentation before using this value for engineering calculations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Configuration Breakdown — Decode the Order Code\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe complete ordering reference can be organized into functional blocks. The descriptions below follow the configuration information supplied for this product; verify the full code against the manufacturer's ordering documentation before selecting a replacement.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode segment\u003c\/th\u003e\n\u003cth\u003eSupplied meaning\u003c\/th\u003e\n\u003cth\u003eSelection relevance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMDX61\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOVIDRIVE B series; options can be installed\u003c\/td\u003e\n\u003ctd\u003eIdentifies the drive family and option-capable configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVersion B\u003c\/td\u003e\n\u003ctd\u003eImportant when matching the installed hardware generation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0022\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRecommended motor power: 2.2 kW\u003c\/td\u003e\n\u003ctd\u003eCompare the motor's rated power and current with the drive rating.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupply voltage: 380–500 V AC\u003c\/td\u003e\n\u003ctd\u003eMust match the available three-phase supply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC2 radio-interference suppression on the line side\u003c\/td\u003e\n\u003ctd\u003eRelevant to the installation's EMC requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-phase connection\u003c\/td\u003e\n\u003ctd\u003eConfirms the stated supply connection type.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour-quadrant configuration with brake chopper\u003c\/td\u003e\n\u003ctd\u003eRelevant to deceleration, braking, and energy-handling requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard type\u003c\/td\u003e\n\u003ctd\u003eConfirm the required options and interfaces separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eComplete configuration:\u003c\/strong\u003e MDX61B0022-5A3-4-00 — SEW MOVIDRIVE B inverter drive, 2.2 kW class, three-phase 380–500 V AC supply, C2 suppression designation, and four-quadrant configuration with brake chopper.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | How the Drive Fits into a Motor Control System\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed control:\u003c\/strong\u003e Varies motor operating speed within the supported drive and motor limits. The actual control mode and achievable performance depend on the configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAcceleration and deceleration:\u003c\/strong\u003e Provides controlled speed transitions when the ramp parameters are configured for the machine's inertia and operating cycle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBraking applications:\u003c\/strong\u003e The listed brake-chopper configuration is relevant where the application generates braking energy. The braking resistor, wiring, duty cycle, and thermal limits must be checked separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomation integration:\u003c\/strong\u003e Can be used in compatible industrial motor-control systems. Verify the control interface, available options, command source, and feedback requirements before integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC planning:\u003c\/strong\u003e The supplied C2 designation is relevant to electromagnetic compatibility. Cable routing, grounding, shielding, and installation conditions still need to follow the manufacturer's instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Typical Equipment and Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyor systems:\u003c\/strong\u003e Adjust motor speed to match material flow and production sequencing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging machinery:\u003c\/strong\u003e Coordinate motor speed changes with machine cycles, subject to the required positioning and synchronization performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixers and process equipment:\u003c\/strong\u003e Control rotational speed according to the process recipe and mechanical load profile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial-handling equipment:\u003c\/strong\u003e Support controlled acceleration and deceleration where the drive rating and braking design are suitable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial machine retrofits:\u003c\/strong\u003e Replace an installed drive when the motor, supply, braking arrangement, control interface, and mounting requirements are compatible.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese are potential application examples, not a guarantee of suitability for every machine. High-inertia loads, frequent braking, constant-torque duty, and high ambient temperatures may require additional derating or a different drive configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Installation and Commissioning Sequence\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the motor:\u003c\/strong\u003e Record rated voltage, current, power, frequency, speed, connection method, and duty information from the motor nameplate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the incoming supply:\u003c\/strong\u003e Confirm the three-phase line voltage and frequency against the drive's specified input range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck cabinet clearances:\u003c\/strong\u003e Use the listed dimensions as an initial layout reference and confirm the manufacturer's required ventilation and mounting clearances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the braking circuit:\u003c\/strong\u003e Confirm whether the application requires a braking resistor and verify its resistance, power rating, duty cycle, wiring, and thermal protection against the drive documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview EMC installation:\u003c\/strong\u003e Follow the specified grounding, shield termination, motor-cable routing, and interference-suppression requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigure drive parameters:\u003c\/strong\u003e Enter the correct motor data and control settings. Check acceleration, deceleration, current limits, and the command source before enabling operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePerform a controlled test:\u003c\/strong\u003e Verify motor rotation, speed response, stop behavior, fault indications, and braking performance under a safe commissioning procedure.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical safety:\u003c\/strong\u003e Isolate and secure the supply before installation or maintenance. The drive's DC link may remain charged after power removal. Observe the manufacturer's discharge waiting time and verify the safe voltage condition before touching internal terminals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Global PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen a motor drive trips, the fault may originate in the supply, motor, mechanical load, braking circuit, wiring, or drive configuration. A structured diagnosis helps prevent repeated trips and unnecessary replacement of functional equipment.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent during acceleration:\u003c\/strong\u003e Review the acceleration ramp, motor data, load inertia, mechanical binding, and motor-cable condition. Compare measured operating current with the drive's rated limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC-bus or overvoltage trips during deceleration:\u003c\/strong\u003e Check the deceleration ramp, load inertia, braking resistor specification, resistor wiring, and brake-chopper configuration. Do not reduce the ramp time without checking the braking limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrive fails to start:\u003c\/strong\u003e Confirm the input supply, enable conditions, command source, interlocks, and active fault state. Verify whether the controller is actually issuing a valid run command.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor speed is unstable:\u003c\/strong\u003e Check motor nameplate parameters, selected control mode, mechanical load changes, feedback wiring if applicable, and parameter consistency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrive trips after replacement:\u003c\/strong\u003e Compare the complete ordering code, option configuration, parameter set, control wiring, and braking arrangement with the original installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnexpected electrical interference:\u003c\/strong\u003e Inspect protective-earth connections, cable shielding, separation of power and signal cables, and installation practices required by the EMC documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eField engineering tip:\u003c\/strong\u003e Record the fault code, operating frequency, output current, DC-bus indication if available, load condition, and the timing of the trip. This information helps distinguish an electrical fault from an acceleration, braking, or mechanical-load problem.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Replacement Selection and Compatibility Checks\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBefore ordering a replacement for the MDX61B0022-5A3-4-00, compare the full model code and application requirements rather than matching only the 2.2 kW rating.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the 380–500 V AC three-phase supply requirement.\u003c\/li\u003e\n\u003cli\u003eMatch the motor's rated current and operating duty to the drive's verified output rating.\u003c\/li\u003e\n\u003cli\u003eCheck the four-quadrant and brake-chopper configuration against the machine's braking requirements.\u003c\/li\u003e\n\u003cli\u003eConfirm the C2 suppression designation and the installation's EMC requirements.\u003c\/li\u003e\n\u003cli\u003eVerify control interfaces, installed options, parameter backup, and communication arrangements.\u003c\/li\u003e\n\u003cli\u003eCheck mounting dimensions, ventilation clearances, and cabinet thermal conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA drive with the same nominal power may not be a direct replacement if its current rating, overload capability, braking arrangement, option configuration, or control interface differs. Obtain the applicable SEW-EURODRIVE technical documentation before approving a substitution.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Warranty, Dispatch and Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e SEW MDX61B0022-5A3-4-00 MOVIDRIVE B inverter drive.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e New and original, subject to order and stock confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months, subject to the seller's written warranty terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch target:\u003c\/strong\u003e Within 24–48 hours after order and stock confirmation, subject to processing requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping methods:\u003c\/strong\u003e FedEx, UPS, or DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuotation support:\u003c\/strong\u003e Provide the complete model code, quantity, destination country, motor rating, and braking requirements for a more accurate compatibility check.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1. Is a 2.2 kW motor automatically compatible with this drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot necessarily. Compare the motor's rated current, voltage, connection, duty, and operating conditions with the drive's verified ratings. Two motors with the same power rating may require different current capacity or overload performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2. Does the brake chopper mean a braking resistor is included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe supplied configuration identifies a brake chopper, but it does not confirm that a braking resistor is included. Check the order contents and the drive manual, then select a resistor that meets the specified resistance, power, duty-cycle, and thermal requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3. What should I check before reusing parameters from the old drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfirm that the replacement has the same hardware configuration, option set, motor characteristics, and control interface. Review motor data, command sources, speed limits, ramps, braking settings, and protection thresholds before enabling the motor. Do not assume that every parameter transfers unchanged.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4. Why might a drive trip only when a machine stops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDuring deceleration, a high-inertia load can return energy to the drive's DC link. Review the fault code, deceleration time, load inertia, and braking circuit. Check the brake-chopper and resistor specifications before changing stop parameters or increasing the braking duty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5. Which information is most useful when requesting a replacement quotation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the full MDX61B0022-5A3-4-00 model number, a clear nameplate photograph, motor voltage and rated current, supply voltage, braking-resistor details if fitted, and the machine's application. This helps identify configuration differences that a power-rating-only comparison may miss.\u003c\/p\u003e","brand":"SEW-EURODRIVE","offers":[{"title":"Default Title","offer_id":67740545253558,"sku":"MDX61B0022-5A3-4-00","price":135.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/MDX61B0022-5A3-4-00-1.jpg?v=1792741631","url":"https:\/\/www.plcsparehub.com\/products\/mdx61b0022-5a3-4-00-sew-movidrive-b-inverter-drive","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}