{"product_id":"lms400-1000-sick-2d-indoor-laser-scanner-sensor-buy-now","title":"LMS400-1000 SICK 2D Indoor Laser Scanner Sensor Buy Now","description":"\u003ch3\u003eEngineering Overview \u0026amp; Optical Profile\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eLMS400-1000\u003c\/strong\u003e\u003c\/span\u003e from \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSICK\u003c\/strong\u003e\u003c\/span\u003e represents a high-precision 2D laser measurement scanner engineered for indoor industrial automation tasks. Operating with a visible red laser diode at 650 nm, this device delivers reliable optical scanning across variable object remissions from 6.5% up to 200%. Factory automation engineers deploy the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eLMS400-1000\u003c\/strong\u003e\u003c\/span\u003e scanner to handle rigorous object profiling, precise dimensional inspection, and advanced container fill-level monitoring.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications \u0026amp; Performance Ratings\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSICK\u003c\/strong\u003e\u003c\/span\u003e Sensor Intelligence\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eLMS400-1000\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eLMS400\u003c\/strong\u003e\u003c\/span\u003e Indoor Series\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e2D Laser Scanner Sensor\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eLight Source \u0026amp; Laser Class\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eVisible Red Light (650 nm), Laser Class 2 (Standby Class 1)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eWorking \u0026amp; Scanning Range\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e0.7 m to 3.0 m (3 m at 10% remission factor)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eScanning Frequency \u0026amp; Response\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e230 Hz to 500 Hz configurable, Response time \u0026gt;= 2 ms\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eAngular Resolution\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e0.1 degrees to 1.0 degrees, configurable\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eSystematic error +- 4 mm, Statistical error 3 mm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eSupply Voltage \u0026amp; Power\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e\u0026lt;= 24 V DC (+- 15%), Power Consumption: 25 W\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eEnclosure \u0026amp; Physical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eAluminum Die Cast, RAL 5012 Light Blue, IP65, 179x107x130 mm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e2.3 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation \u0026amp; Mechanical Deployment\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the scanner securely to rigid machine frames using vibration-damping brackets.\u003c\/li\u003e\n  \u003cli\u003eEnsure an unobstructed optical sight path toward the target reading field.\u003c\/li\u003e\n  \u003cli\u003eConnect the DC power supply ensuring voltage remains within the 24 V nominal limit.\u003c\/li\u003e\n  \u003cli\u003eInterface Ethernet and RS-232 communication lines using shielded industrial cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Operational Usability\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConfigure selectable regions of interest (ROI) via engineering software to match container profiles.\u003c\/li\u003e\n  \u003cli\u003eAdjust scanning frequency between 230 Hz and 500 Hz depending on target velocity.\u003c\/li\u003e\n  \u003cli\u003eMonitor operating health instantly using the six onboard status indicator LEDs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEquipment Compatibility \u0026amp; System Integration\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSupports Ethernet TCP\/IP data interfaces and serial RS-232 service connections.\u003c\/li\u003e\n  \u003cli\u003eProvides 4 digital inputs and 5 digital outputs (4x PNP \/ 1x analog 4-20 mA).\u003c\/li\u003e\n  \u003cli\u003eIntegrates cleanly with standard programmable logic controllers for telegram output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eQuality Standards, Warranty \u0026amp; Fulfillment\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured to strict industrial environmental and optical emission standards.\u003c\/li\u003e\n  \u003cli\u003eBacked by a comprehensive 12-month operational replacement warranty.\u003c\/li\u003e\n  \u003cli\u003eRapid order processing with 24 to 48-hour dispatch via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTypical Industrial Applications \u0026amp; Suitable Equipment\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomated container level control and fill-monitoring systems.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling sorting bins and packaging verification stations.\u003c\/li\u003e\n  \u003cli\u003eDimensional sorting machinery for irregularly shaped components.\u003c\/li\u003e\n  \u003cli\u003eConveyor belt product profiling setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eBuilt-In Diagnostic Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eReal-time error logging for optical path obstructions or lens contamination.\u003c\/li\u003e\n  \u003cli\u003eInternal temperature tracking to prevent thermal operational drift.\u003c\/li\u003e\n  \u003cli\u003eStatus telegram generation for immediate communication failure detection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eDuring an automated warehouse bin monitoring setup, technicians noticed erratic level output spikes from the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eLMS400-1000\u003c\/strong\u003e\u003c\/span\u003e scanner when empty containers passed through. Field inspection revealed that dust accumulation on the optical window scattered the 650 nm red light beam, causing false remission values. Implementing a scheduled optical face wipe procedure and optimizing the column width filter settings in software completely eliminated the false triggers and restored stable level readings.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e What causes inconsistent measurement results when scanning dark targets?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Dark surfaces with low remission factors absorb light; ensure your target objects meet or exceed the 6.5% remission threshold specified for reliable detection.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e Can this scanner be used for primary safety protection around moving machinery?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e No, the sensor does not constitute a safety component as defined by relevant machine safety legislation and must not be used for personnel protection.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e How do I configure custom detection areas within the monitoring field?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Use the configuration software to define selectable regions of interest (ROI) ranging from 50 mm x 3,000 mm up to 1,000 mm x 1,750 mm.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e What maintenance steps are required if the enclosure rating is IP65?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Periodically inspect the aluminum die-cast housing seals and clean the glass optics window with a non-abrasive lint-free cloth.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e How are measurement values transmitted back to the host controller?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Height values and status data can be transmitted via Ethernet TCP\/IP telegrams, digital outputs, or the 4-20 mA analog output channel.\u003c\/p\u003e\n\n\u003ch3\u003eSelection \u0026amp; Purchasing Guide\u003c\/h3\u003e\n\u003cp\u003eWhen selecting a 2D optical measuring scanner for industrial level control, verify your target object's minimum dimensions and reflection characteristics. Ensure your mounting distance falls within the 0.7 m to 3.0 m working range. Purchasing verified industrial automation hardware ensures dependable plant performance and accurate data logging.\u003c\/p\u003e","brand":"SICK","offers":[{"title":"Default Title","offer_id":50493465002166,"sku":"LMS400-1000","price":209.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/LMS400-10002.jpg?v=1790058239","url":"https:\/\/www.plcsparehub.com\/products\/lms400-1000-sick-2d-indoor-laser-scanner-sensor-buy-now","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}