{"product_id":"kj4001x1-be1-emerson-deltav-series-shielded-i-o-carrier-8-wide","title":"KJ4001X1-BE1 Emerson DeltaV Series Shielded I\/O Carrier | 8-Wide","description":"\u003ch3\u003e\u003cstrong\u003eHardware Architecture | 8-Wide I\/O Carrier with Shield\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #1673b9;\"\u003e\u003cstrong\u003eEmerson KJ4001X1-BE1\u003c\/strong\u003e\u003c\/span\u003e, identified by part number \u003cstrong\u003e12P0818X072\u003c\/strong\u003e, is an 8-Wide I\/O Carrier with Shield for the \u003cstrong\u003eDeltaV distributed control system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis carrier provides the physical mounting and LocalBus infrastructure for compatible I\/O hardware. Its 8-Wide configuration accommodates the specified I\/O assembly arrangement within a DeltaV control cabinet.\u003c\/p\u003e\n\u003cp\u003eThe integrated shield supports the carrier's intended installation configuration. Its electrical architecture supports a 12.6 VDC LocalBus supply with a rated capacity of 15 A.\u003c\/p\u003e\n\u003cp\u003eEngineers can use this carrier as part of a distributed I\/O installation. Proper carrier selection helps maintain mechanical alignment, power distribution, and LocalBus connectivity across the control system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Identification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #1673b9;\"\u003e\u003cstrong\u003eKJ4001X1-BE1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12P0818X072\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDeltaV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/O Carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCarrier Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-Wide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShield Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-6.5 AMP (as specified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.6-30 VDC (as specified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocalBus Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.6 VDC at 15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | LocalBus Power Distribution\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe carrier forms part of the DeltaV I\/O power and communication infrastructure. Its LocalBus power specification is particularly important when engineers plan carrier arrangements and system loading.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocalBus Voltage\u003c\/td\u003e\n\u003ctd\u003e12.6 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocalBus Current Capacity\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Identification on Supplied Description\u003c\/td\u003e\n\u003ctd\u003e12.6-30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Identification on Supplied Description\u003c\/td\u003e\n\u003ctd\u003e8-6.5 AMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Consideration:\u003c\/strong\u003e The 15 A rating specifically describes LocalBus power. Do not interpret it as the allowable current for every individual I\/O connection.\u003c\/p\u003e\n\u003cp\u003eThe supplied description also lists 8-6.5 AMP and 12.6-30 VDC. Verify these markings against the product nameplate and applicable hardware documentation before using them for electrical design.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Environmental Qualification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe carrier supports demanding industrial installation environments. Its specified environmental limits cover temperature, humidity, mechanical shock, vibration, and airborne contaminants.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecified Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10g, ½ Sinewave, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration, Low Frequency\u003c\/td\u003e\n\u003ctd\u003e1 mm Peak-to-Peak, 2 to 13.2 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration, High Frequency\u003c\/td\u003e\n\u003ctd\u003e0.7g, 13.2 to 150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirborne Contaminants\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985, Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Implications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain cabinet temperatures within the specified operating range.\u003c\/li\u003e\n\u003cli\u003ePrevent condensation during operation and environmental transitions.\u003c\/li\u003e\n\u003cli\u003eConsider cabinet vibration when selecting mounting locations.\u003c\/li\u003e\n\u003cli\u003eEvaluate corrosive airborne contaminants in industrial environments.\u003c\/li\u003e\n\u003cli\u003eMaintain suitable cabinet ventilation and environmental protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Hazardous Area Approvals\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe supplied product information identifies several hazardous-location approvals. These certifications support installation assessment in designated industrial environments.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMarking \/ Certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX\u003c\/td\u003e\n\u003ctd\u003eII 3G Ex ec IIC Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Certificate\u003c\/td\u003e\n\u003ctd\u003eFM16ATEX0056U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUKEX Certificate\u003c\/td\u003e\n\u003ctd\u003eFM21UKEX0017U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNorth American Classification\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 2, Groups A, B, C, D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNorth American Zone Classification\u003c\/td\u003e\n\u003ctd\u003eClass I, Zone 2, AEx\/Ex ec IIC Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUS Certificate\u003c\/td\u003e\n\u003ctd\u003eFM17US0286U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanadian Certificate\u003c\/td\u003e\n\u003ctd\u003eFM17CA0145U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Note:\u003c\/strong\u003e Verify the exact certification marking on the installed hardware. Follow the applicable hazardous-area installation requirements and system approval conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Carrier Expansion and Interconnection Limits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eDeltaV carrier installations require careful attention to LocalBus extension length and enclosure interconnection methods.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMandatory Design Restrictions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe combined length of I\/O Carriers and LocalBus Extenders must not exceed 6.5 meters.\u003c\/li\u003e\n\u003cli\u003eInterconnecting cables between enclosures must run inside conduit.\u003c\/li\u003e\n\u003cli\u003eVerify the complete carrier arrangement before final cabinet installation.\u003c\/li\u003e\n\u003cli\u003eMaintain correct LocalBus connections throughout the I\/O assembly.\u003c\/li\u003e\n\u003cli\u003eCheck system power distribution before energizing the installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhy the 6.5-Meter Limit Matters:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExceeding the specified combined length can violate the carrier interconnection requirements. Engineers should calculate the complete arrangement rather than checking individual cable sections independently.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Installation and Power Isolation Procedure\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #1673b9;\"\u003e\u003cstrong\u003eKJ4001X1-BE1\u003c\/strong\u003e\u003c\/span\u003e requires power isolation before removal or insertion. Hot insertion and removal are not permitted.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eIdentify the affected I\/O carrier assembly.\u003c\/li\u003e\n\u003cli\u003eReview the system shutdown and isolation procedure.\u003c\/li\u003e\n\u003cli\u003eDe-energize the system before disconnecting the carrier.\u003c\/li\u003e\n\u003cli\u003eDisconnect LocalBus Extender cables only after power isolation.\u003c\/li\u003e\n\u003cli\u003eInspect carrier connectors and mechanical mounting points.\u003c\/li\u003e\n\u003cli\u003eVerify the correct replacement model and part number.\u003c\/li\u003e\n\u003cli\u003eInstall the carrier according to the approved system arrangement.\u003c\/li\u003e\n\u003cli\u003eReconnect LocalBus connections and inspect cable routing.\u003c\/li\u003e\n\u003cli\u003eVerify power distribution before restoring system operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eCritical Restriction:\u003c\/strong\u003e Never remove or insert this carrier while system power remains energized. Disconnecting LocalBus Extender cables also requires prior power de-energization.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Maintenance and Service Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis carrier contains no user-serviceable parts. Its design does not require routine calibration or internal adjustment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended Maintenance Activities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInspect the carrier housing for physical damage.\u003c\/li\u003e\n\u003cli\u003eCheck mounting stability and connector alignment.\u003c\/li\u003e\n\u003cli\u003eInspect LocalBus connections for secure installation.\u003c\/li\u003e\n\u003cli\u003eReview enclosure cable routing and conduit protection.\u003c\/li\u003e\n\u003cli\u003eCheck for excessive dust, moisture, and corrosion.\u003c\/li\u003e\n\u003cli\u003eVerify the system's power distribution arrangement.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified carrier and extender length limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eService Restrictions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNo user-serviceable internal components.\u003c\/li\u003e\n\u003cli\u003eDo not disassemble the carrier.\u003c\/li\u003e\n\u003cli\u003eNo calibration required.\u003c\/li\u003e\n\u003cli\u003eNo internal adjustment required.\u003c\/li\u003e\n\u003cli\u003eDe-energize system power before removal or insertion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eReplace the complete carrier assembly when physical damage or connector failure affects reliable operation. Follow Emerson's approved maintenance procedures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Compatibility and Replacement Assessment\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBefore selecting \u003cspan style=\"color: #1673b9;\"\u003e\u003cstrong\u003eKJ4001X1-BE1\u003c\/strong\u003e\u003c\/span\u003e, verify its mechanical and electrical compatibility with the existing DeltaV I\/O assembly.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVerification Item\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eMatch KJ4001X1-BE1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eConfirm 12P0818X072\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Width\u003c\/td\u003e\n\u003ctd\u003eConfirm 8-Wide configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield Configuration\u003c\/td\u003e\n\u003ctd\u003eVerify shield requirement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocalBus Power\u003c\/td\u003e\n\u003ctd\u003eCheck 12.6 VDC \/ 15 A specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterconnection\u003c\/td\u003e\n\u003ctd\u003eConfirm combined length within 6.5 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area\u003c\/td\u003e\n\u003ctd\u003eVerify applicable installation approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Wiring\u003c\/td\u003e\n\u003ctd\u003eConfirm conduit requirements between enclosures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement Engineering Advice:\u003c\/strong\u003e Do not substitute another carrier based solely on its physical width. Verify the complete part number, shield arrangement, LocalBus architecture, and system installation requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Packaging and Supply Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Emerson.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KJ4001X1-BE1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 12P0818X072.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Description:\u003c\/strong\u003e 8-Wide I\/O Carrier with Shield.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Quantity:\u003c\/strong\u003e 1 I\/O Carrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Accessories:\u003c\/strong\u003e Confirm separately before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact our sales team to confirm the exact supplied configuration and packaging contents.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the engineering difference between an I\/O carrier and an I\/O module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn I\/O carrier provides the physical and electrical infrastructure for compatible I\/O hardware. An I\/O module performs the actual signal processing, such as analog input or digital output. Replacing a carrier does not automatically replace the installed signal modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does the shield configuration eliminate the need for proper cabinet grounding?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The shield does not replace the cabinet grounding and bonding design. Engineers must follow the system grounding instructions and maintain appropriate cable shielding practices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What should technicians inspect when LocalBus communication becomes unstable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart by checking connector seating, extender cable condition, carrier alignment, and total interconnection length. Also inspect power distribution and cabinet environmental conditions. Isolate power before disturbing any carrier or LocalBus connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can engineers install this carrier in a separate control enclosure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnclosure interconnection requires the connecting cable to run inside conduit. The complete carrier and extender arrangement must also remain within the 6.5-meter combined length limit. Review the approved system topology before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How should maintenance teams handle a carrier that shows physical connector damage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDo not attempt internal repairs or mechanical modifications. This assembly contains no user-serviceable parts. Isolate system power, follow the approved replacement procedure, and verify connector integrity before restoring operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProcurement and Technical Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWe provide industrial automation components for distributed control systems, PLC platforms, and process automation equipment.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Emerson DeltaV 8-Wide I\/O Carrier with Shield.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KJ4001X1-BE1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 12P0818X072.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e DHL, FedEx, and UPS international delivery options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupport:\u003c\/strong\u003e Model verification and system compatibility assistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSend us your required quantity and destination. Contact our team today for a quotation, availability confirmation, and technical purchasing assistance.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":68027768438966,"sku":"KJ4001X1-BE1","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/KJ4001X1-BE1-3.jpg?v=1794280454","url":"https:\/\/www.plcsparehub.com\/products\/kj4001x1-be1-emerson-deltav-series-shielded-i-o-carrier-8-wide","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}