{"product_id":"kfd2-sr2-ex1-w-lb-pepperl-fuchs-switch-amplifier","title":"KFD2-SR2-Ex1.W.LB Pepperl+Fuchs Switch Amplifier","description":"\u003ch3\u003e\u003cb\u003ePepperl+Fuchs KFD2-SR2-Ex1.W.LB Switch Amplifier\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #1565c0;\"\u003eKFD2-SR2-Ex1.W.LB\u003c\/strong\u003e is a one-channel isolated switch amplifier from \u003cstrong\u003ePepperl+Fuchs\u003c\/strong\u003e. It interfaces dry contact and NAMUR sensors with control-side equipment in industrial automation systems.\u003c\/p\u003e\n\u003cp\u003eThe module transfers field input signals through reinforced galvanic isolation and provides relay-based control outputs. Its second output can be configured for signal transmission or fault indication. The device also supports line fault detection (LFD), reversible operating modes, and signal splitting with one input and two outputs.\u003c\/p\u003e\n\u003cp\u003eDesigned for safety-related applications up to \u003cstrong\u003eSIL 2\u003c\/strong\u003e and systematic capability \u003cstrong\u003eSC 3\u003c\/strong\u003e according to IEC\/EN 61508, this switch amplifier supports reliable signal conditioning between hazardous-area field devices and control systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e01 | Signal Path and Functional Architecture\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSignal Stage\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eTechnical Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Input\u003c\/td\u003e\n\u003ctd\u003eSensor signal acquisition\u003c\/td\u003e\n\u003ctd\u003eDry contact or NAMUR input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Monitoring\u003c\/td\u003e\n\u003ctd\u003eField circuit supervision\u003c\/td\u003e\n\u003ctd\u003eLine fault detection for cable breakage and short circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eSwitching logic\u003c\/td\u003e\n\u003ctd\u003eReversible operating mode, DIP switch configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput I\u003c\/td\u003e\n\u003ctd\u003eControl signal transmission\u003c\/td\u003e\n\u003ctd\u003eRelay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput II\u003c\/td\u003e\n\u003ctd\u003eSignal duplication or fault reporting\u003c\/td\u003e\n\u003ctd\u003eRelay output, configurable for signal or fault message\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Fault Reporting\u003c\/td\u003e\n\u003ctd\u003eCollective fault indication\u003c\/td\u003e\n\u003ctd\u003ePower Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eFunctional highlights:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOne-channel isolated barrier for digital input signals.\u003c\/li\u003e\n\u003cli\u003eCompatible with dry contact and NAMUR field devices.\u003c\/li\u003e\n\u003cli\u003eOne input with two relay outputs for signal splitting.\u003c\/li\u003e\n\u003cli\u003eLine fault detection for open-circuit and short-circuit conditions.\u003c\/li\u003e\n\u003cli\u003eReversible switching behavior through DIP switch configuration.\u003c\/li\u003e\n\u003cli\u003ePower supply through Power Rail or terminals 14+ and 15-.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e02 | Terminal Assignment and Wiring Reference\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1+, 2+, 3-\u003c\/td\u003e\n\u003ctd\u003eField side\u003c\/td\u003e\n\u003ctd\u003eDigital input connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7, 8, 9\u003c\/td\u003e\n\u003ctd\u003eControl side\u003c\/td\u003e\n\u003ctd\u003eRelay Output I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10, 11, 12\u003c\/td\u003e\n\u003ctd\u003eControl side\u003c\/td\u003e\n\u003ctd\u003eRelay Output II: signal or fault message\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14+, 15-\u003c\/td\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e19–30 V DC supply connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe device supports two supply connection methods: Power Rail or direct terminal wiring. When using a Power Rail installation, the collective error message can also be transmitted through the rail.\u003c\/p\u003e\n\u003cp\u003eAlways confirm the terminal diagram on the device label and the manufacturer's wiring documentation before connecting field or control-side circuits.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e03 | NAMUR Input Characteristics and Fault Detection\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Sensor\u003c\/td\u003e\n\u003ctd\u003eDry contact or NAMUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003eApproximately 8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Current\u003c\/td\u003e\n\u003ctd\u003eApproximately 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Point\u003c\/td\u003e\n\u003ctd\u003e1.2–2.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Hysteresis\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Break Detection\u003c\/td\u003e\n\u003ctd\u003eInput current ≤ 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Detection\u003c\/td\u003e\n\u003ctd\u003eInput current greater than 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Pulse Duration\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Pause Duration\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eLine fault detection behavior:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal input range:\u003c\/strong\u003e The NAMUR signal is evaluated according to the configured switching thresholds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen circuit:\u003c\/strong\u003e Input current at or below 0.1 mA indicates a line break condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort circuit:\u003c\/strong\u003e Input current above 6 mA indicates a short-circuit condition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese thresholds allow the control system to distinguish sensor switching states from wiring faults. Correct field wiring and sensor compatibility remain essential for reliable fault detection.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e04 | Relay Outputs and Switching Capacity\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe two relay outputs provide separate control-side connections. Output I transfers the input signal. Output II can transfer the signal or provide a fault message, depending on the configuration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Parameter\u003c\/th\u003e\n\u003cth\u003eRating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput I\u003c\/td\u003e\n\u003ctd\u003eRelay, terminals 7, 8, 9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput II\u003c\/td\u003e\n\u003ctd\u003eRelay, terminals 10, 11, 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V AC Contact Load\u003c\/td\u003e\n\u003ctd\u003e2 A, cos φ greater than 0.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e126.5 V AC Contact Load\u003c\/td\u003e\n\u003ctd\u003e4 A, cos φ greater than 0.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40 V DC Contact Load\u003c\/td\u003e\n\u003ctd\u003e2 A, resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Switching Current\u003c\/td\u003e\n\u003ctd\u003e2 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperate Delay\u003c\/td\u003e\n\u003ctd\u003eApproximately 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelease Delay\u003c\/td\u003e\n\u003ctd\u003eApproximately 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Life\u003c\/td\u003e\n\u003ctd\u003e10⁷ switching cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switching Frequency\u003c\/td\u003e\n\u003ctd\u003e10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor FM-approved applications, the listed 30 V DC contact rating is 2 A with a resistive load. Check the applicable approval documentation and load category before selecting the switching circuit.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e05 | Power Supply and Electrical Isolation\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Connection\u003c\/td\u003e\n\u003ctd\u003ePower Rail or terminals 14+, 15-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e19–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermitted Ripple\u003c\/td\u003e\n\u003ctd\u003e≤ 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e≤ 45 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e≤ 0.9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e≤ 0.9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic isolation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput to output: reinforced insulation, 300 V RMS rated insulation voltage.\u003c\/li\u003e\n\u003cli\u003eInput to power supply: reinforced insulation, 300 V RMS rated insulation voltage.\u003c\/li\u003e\n\u003cli\u003eOutput to power supply: reinforced insulation, 300 V RMS rated insulation voltage.\u003c\/li\u003e\n\u003cli\u003eOutput to output: reinforced insulation, 300 V RMS rated insulation voltage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe reinforced isolation separates field, control, and supply circuits. This helps prevent unwanted electrical interaction between connected circuit groups.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e06 | Functional Safety and Hazardous-Area Approvals\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eSIL 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystematic Capability\u003c\/td\u003e\n\u003ctd\u003eSC 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Safety Standard\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61508:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEU-type examination certificate:\u003c\/strong\u003e PTB 00 ATEX 2080\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eApproval \/ Protection Type\u003c\/th\u003e\n\u003cth\u003eMarking or Certificate\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Intrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eII (1)G [Ex ia Ga] IIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Dust Protection\u003c\/td\u003e\n\u003ctd\u003eII (1)D [Ex ia Da] IIIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMining Application\u003c\/td\u003e\n\u003ctd\u003eI (M1) [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional ATEX Marking\u003c\/td\u003e\n\u003ctd\u003eII (3)G [Ex ic Gc] IIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional ATEX Certificate\u003c\/td\u003e\n\u003ctd\u003eTÜV 99 ATEX 1493 X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Protection Marking\u003c\/td\u003e\n\u003ctd\u003eII 3G Ex ec nC IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIECEx Certificates\u003c\/td\u003e\n\u003ctd\u003eIECEx PTB 11.0034; IECEx TUN 19.0013X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIECEx Markings\u003c\/td\u003e\n\u003ctd\u003e[Ex ia Ga] IIC; [Ex ia Da] IIIC; [Ex ia Ma] I; Ex ec nC IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFM Certificate\u003c\/td\u003e\n\u003ctd\u003eFM19US0207X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFM Control Drawing\u003c\/td\u003e\n\u003ctd\u003e116-0035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL Certificate\u003c\/td\u003e\n\u003ctd\u003eE106378\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecULus Control Drawing\u003c\/td\u003e\n\u003ctd\u003e116-0473\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous-area input parameters:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eEx ia \/ Ex ic Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Uo\u003c\/td\u003e\n\u003ctd\u003e10.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Io\u003c\/td\u003e\n\u003ctd\u003e13 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Po\u003c\/td\u003e\n\u003ctd\u003e34 mW, linear characteristic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum safe voltage Um:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupply: 253 V AC \/ 125 V DC.\u003c\/li\u003e\n\u003cli\u003eRelay output: 253 V AC.\u003c\/li\u003e\n\u003cli\u003eFault indication output: 40 V DC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Um is a maximum safe voltage, not the normal operating voltage or rated load voltage. The actual permissible circuit voltage must follow the applicable product ratings and approval documents.\u003c\/p\u003e\n\u003cp\u003eHazardous-area installation requires verification of the complete intrinsic safety loop, including field-device parameters, cable capacitance, cable inductance, and the associated control-side equipment. The module's approval alone does not establish suitability for every installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e07 | Environmental, Mechanical and Compliance Data\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 °C (-40 to +158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail according to EN 60715:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e20 × 119 × 115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Type\u003c\/td\u003e\n\u003ctd\u003eB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLED indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDIP switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabeling\u003c\/td\u003e\n\u003ctd\u003eFront labeling area\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable directives and standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEMC Directive 2014\/30\/EU: EN 61326-1:2013.\u003c\/li\u003e\n\u003cli\u003eLow Voltage Directive 2014\/35\/EU: EN 61010-1:2010 and listed amendments.\u003c\/li\u003e\n\u003cli\u003eEMC conformity: NE 21:2017, EN 61326-3-1:2017, EN IEC 61326-3-2:2018.\u003c\/li\u003e\n\u003cli\u003eFunctional safety: IEC\/EN 61508:2010.\u003c\/li\u003e\n\u003cli\u003eNAMUR input: EN 60947-5-6:2000.\u003c\/li\u003e\n\u003cli\u003eEnclosure protection: IEC 60529.\u003c\/li\u003e\n\u003cli\u003eATEX-related standards: EN IEC 60079-0, EN 60079-7, EN IEC 60079-11, and EN IEC 60079-15 as listed in the product documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e08 | Commissioning and Field Maintenance Notes\u003c\/b\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify sensor type:\u003c\/strong\u003e Confirm whether the field device is a dry contact or NAMUR sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck input wiring:\u003c\/strong\u003e Verify terminal polarity and the connections at 1+, 2+, and 3-.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet operating mode:\u003c\/strong\u003e Check DIP switch positions against the required switching and fault response logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview output assignment:\u003c\/strong\u003e Confirm whether Output II is configured for signal duplication or fault reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck supply voltage:\u003c\/strong\u003e Measure the DC supply at the module and confirm it remains within 19–30 V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest LFD response:\u003c\/strong\u003e Perform approved open-circuit and short-circuit tests to verify field wiring supervision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify relay operation:\u003c\/strong\u003e Confirm switching response and connected load ratings during functional testing.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor safety-related applications, verify the complete safety function, configuration, and proof-test requirements against the applicable safety manual and project documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e09 | Supply, Warranty and Delivery\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Information\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eKFD2-SR2-Ex1.W.LB\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSwitch Amplifier \/ Isolated Barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003eOne-channel dry contact or NAMUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eTwo relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Condition\u003c\/td\u003e\n\u003ctd\u003eNew \u0026amp; Original in Factory Packing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eFactory Warranty: 12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping\u003c\/td\u003e\n\u003ctd\u003eFedEx, UPS, DHL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eContact Global PLC Spare HUB for KFD2-SR2-Ex1.W.LB pricing, availability, and delivery information. Provide your sensor type and required output configuration when requesting a quotation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e10 | Engineering FAQs\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How should I select the DIP switch settings when replacing an existing unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecord the original switch positions before removing the old module. Compare them with the required input logic, reversible operating mode, and Output II assignment. Do not assume that a replacement module will operate correctly with factory-default settings. Confirm the final configuration against the wiring diagram and application logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Why might the relay output fail to switch even when the input LED changes state?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the selected operating mode, relay contact wiring, connected load, and output assignment. Also verify that the load does not fall below the specified minimum switching current or exceed the applicable contact rating. An input indication confirms signal detection, but it does not independently prove the external relay circuit is wired correctly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can the second relay output be used to send a separate alarm to the PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Output II can be configured for a signal or fault message. For a separate alarm, verify the selected DIP switch configuration and PLC input wiring. If Output II is assigned to fault reporting, it should not simultaneously be treated as an independent duplicate process signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What should engineers verify when connecting a NAMUR sensor through a long field cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the sensor's NAMUR compatibility, cable insulation, wiring polarity, and the total cable capacitance and inductance. Confirm that the measured current remains within the intended switching range. For hazardous-area circuits, include cable parameters in the intrinsic safety assessment rather than checking the barrier values alone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What is the main difference between a switch amplifier and a standard digital input card in this application?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA switch amplifier provides signal conditioning and galvanic isolation between field and control circuits. This model also supports NAMUR signal evaluation, line fault detection, and relay-based output separation. A standard PLC digital input may not provide the same intrinsic safety interface or field wiring supervision. Select the device according to the sensor, hazardous-area classification, and required safety architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/KFD2-SR2-EX1.W.LB.png?v=1795421904\" alt=\"\"\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":68128911491254,"sku":"KFD2-SR2-Ex1.W.LB","price":104.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/KFD2-SR2-EX1.W.LB-1.jpg?v=1795421904","url":"https:\/\/www.plcsparehub.com\/products\/kfd2-sr2-ex1-w-lb-pepperl-fuchs-switch-amplifier","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}