{"product_id":"kfd2-sl2-ex2-pepperl-fuchs-dual-channel-barrier-kfd2-series","title":"KFD2-SL2-Ex2 Pepperl+Fuchs Dual Channel Barrier KFD2 Series","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview | Dual-Channel Solenoid Control\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0066cc;\"\u003ePepperl+Fuchs KFD2-SL2-Ex2\u003c\/span\u003e\u003c\/strong\u003e is a two-channel isolated solenoid driver for industrial hazardous-area applications. It converts control-side logic signals into intrinsically safe output signals for compatible field loads.\u003c\/p\u003e\n\u003cp\u003eEach channel provides a dedicated field-side output connection. The module accepts non-polarized logic inputs and operates from a 20–30 V DC supply. Its output delivers up to 45 mA at a minimum voltage of 11.7 V under the specified operating conditions.\u003c\/p\u003e\n\u003cp\u003eIntegrated Line Fault Detection (LFD) monitors field wiring for open circuits and short circuits. DIP switches provide configuration options, while front-panel LEDs support local status checks.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eKFD2 Series\u003c\/strong\u003e architecture combines dual-channel signal isolation, intrinsically safe output circuits, and functional safety capabilities. The module supports applications up to \u003cstrong\u003eSIL 2\u003c\/strong\u003e according to IEC\/EN 61508.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Product Identity and Functional Highlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIdentification\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eKFD2-SL2-Ex2\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eKFD2 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSolenoid Driver \/ Isolated Barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd\u003e2 Independent Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Classification\u003c\/td\u003e\n\u003ctd\u003eDigital Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Input\u003c\/td\u003e\n\u003ctd\u003eNon-Polarized Logic Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Output\u003c\/td\u003e\n\u003ctd\u003eIntrinsically Safe Driver Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e20–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e45 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Output Voltage\u003c\/td\u003e\n\u003ctd\u003e11.7 V DC at the specified output load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Monitoring\u003c\/td\u003e\n\u003ctd\u003eIntegrated LFD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDIP Switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Indication\u003c\/td\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Safety\u003c\/td\u003e\n\u003ctd\u003eUp to SIL 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Electrical Interface and Signal Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eA. Power Supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated operating voltage: 20–30 V DC.\u003c\/li\u003e\n\u003cli\u003ePower connection: Power Rail or terminals 14+ and 15-.\u003c\/li\u003e\n\u003cli\u003eMaximum power consumption: 3.3 W at 45 mA output current.\u003c\/li\u003e\n\u003cli\u003eMaximum safe voltage Um: 40 V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eB. Control-Side Logic Input\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Side\u003c\/td\u003e\n\u003ctd\u003eControl Side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003e7, 8, 9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003eNon-Polarized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003eApproximately 3 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic 1 Signal\u003c\/td\u003e\n\u003ctd\u003e16–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic 0 Signal\u003c\/td\u003e\n\u003ctd\u003e0–5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eC. Field-Side Output\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Side\u003c\/td\u003e\n\u003ctd\u003eField Side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel 1\u003c\/td\u003e\n\u003ctd\u003eTerminals 1+, 2-, 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel 2\u003c\/td\u003e\n\u003ctd\u003eTerminals 4+, 5-, 6-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Resistance Ri\u003c\/td\u003e\n\u003ctd\u003e272 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Ie\u003c\/td\u003e\n\u003ctd\u003e≤ 45 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Ue\u003c\/td\u003e\n\u003ctd\u003e≥ 11.7 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-Circuit Voltage Us\u003c\/td\u003e\n\u003ctd\u003eMinimum 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergized Delay\u003c\/td\u003e\n\u003ctd\u003e≤ 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDe-Energized Delay\u003c\/td\u003e\n\u003ctd\u003e≤ 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe output values apply to rated operating voltages between 20 and 30 V DC. Verify the field load requirements before connecting the solenoid or actuator.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Line Fault Detection and Diagnostic Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe integrated LFD function monitors the field-side output circuit. It helps maintenance teams distinguish wiring faults from normal switching conditions.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostic Condition\u003c\/th\u003e\n\u003cth\u003eDetection Threshold\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen Circuit\u003c\/td\u003e\n\u003ctd\u003eResistance \u0026gt; 10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit\u003c\/td\u003e\n\u003ctd\u003eResistance \u0026lt; 50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 650 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Intrinsic Safety and Functional Safety\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eKFD2-SL2-Ex2\u003c\/strong\u003e provides intrinsically safe output circuits for compatible hazardous-area loads. Its field-side electrical parameters define the permitted connection conditions.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic Safety Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Concept\u003c\/td\u003e\n\u003ctd\u003eEx ia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Group\u003c\/td\u003e\n\u003ctd\u003eIIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Voltage Uo\u003c\/td\u003e\n\u003ctd\u003e28 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current Io\u003c\/td\u003e\n\u003ctd\u003e110 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Power Po\u003c\/td\u003e\n\u003ctd\u003e770 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Characteristic\u003c\/td\u003e\n\u003ctd\u003eLinear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Safe Supply Voltage Um\u003c\/td\u003e\n\u003ctd\u003e40 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Safety Level\u003c\/td\u003e\n\u003ctd\u003eUp to SIL 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standard\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Parameter Distinction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUo, Io, and Po describe intrinsic safety output parameters.\u003c\/li\u003e\n\u003cli\u003eUs, Ie, and Ue describe normal output operating characteristics.\u003c\/li\u003e\n\u003cli\u003eUm specifies the maximum safe voltage for the supply circuit.\u003c\/li\u003e\n\u003cli\u003eThese values serve different engineering purposes and are not interchangeable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor safety instrumented applications, verify the complete safety function and its system-level calculations. The module's SIL capability alone does not establish the SIL rating of the complete installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Galvanic Isolation and Electrical Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module separates the control input, power supply, and field output circuits through reinforced insulation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIsolation Interface\u003c\/th\u003e\n\u003cth\u003eInsulation Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput \/ Output\u003c\/td\u003e\n\u003ctd\u003eReinforced insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput \/ Power Supply\u003c\/td\u003e\n\u003ctd\u003eReinforced insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply \/ Output\u003c\/td\u003e\n\u003ctd\u003eReinforced insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e300 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Standard\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis isolation architecture helps separate control-side logic signals from field-side hazardous-area circuits. It also reduces direct electrical coupling between the connected circuit sections.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Installation and Terminal Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Connection Reference\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1+, 2-, 3\u003c\/td\u003e\n\u003ctd\u003eChannel 1 Field Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4+, 5-, 6-\u003c\/td\u003e\n\u003ctd\u003eChannel 2 Field Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7, 8, 9\u003c\/td\u003e\n\u003ctd\u003eControl-Side Logic Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14+, 15-\u003c\/td\u003e\n\u003ctd\u003eDC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Requirements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module on a 35 mm DIN rail according to EN 60715.\u003c\/li\u003e\n\u003cli\u003eUse the Power Rail system or designated supply terminals.\u003c\/li\u003e\n\u003cli\u003eCheck terminal assignments against the wiring diagram.\u003c\/li\u003e\n\u003cli\u003eMaintain suitable cabinet ventilation.\u003c\/li\u003e\n\u003cli\u003eKeep field wiring separate from unrelated power circuits.\u003c\/li\u003e\n\u003cli\u003eObserve hazardous-area wiring and segregation requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower Rail Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports Power Rail supply distribution. This arrangement can simplify cabinet power wiring when several compatible interface modules share the same supply system.\u003c\/p\u003e\n\u003cp\u003eCheck Power Rail compatibility and current capacity before installation. Do not assume that every KFD2 module uses the same rail configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | DIP Switch Configuration and Commissioning\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides DIP switches for configuration. Front-panel LEDs help technicians inspect operating conditions during commissioning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended Commissioning Procedure\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eVerify the complete model designation.\u003c\/li\u003e\n\u003cli\u003eCheck the available DC supply voltage.\u003c\/li\u003e\n\u003cli\u003eInspect the control-side logic input wiring.\u003c\/li\u003e\n\u003cli\u003eConfirm the required DIP switch settings using the manufacturer's manual.\u003c\/li\u003e\n\u003cli\u003eCheck both field output connections independently.\u003c\/li\u003e\n\u003cli\u003eTest each channel with its intended field load.\u003c\/li\u003e\n\u003cli\u003eVerify the LFD response under approved test conditions.\u003c\/li\u003e\n\u003cli\u003eConfirm the receiving system recognizes the correct output states.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance Recommendations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInspect screw terminals for loose connections.\u003c\/li\u003e\n\u003cli\u003eCheck field cable insulation and continuity.\u003c\/li\u003e\n\u003cli\u003eReview abnormal LED indications.\u003c\/li\u003e\n\u003cli\u003eVerify output voltage under the actual connected load.\u003c\/li\u003e\n\u003cli\u003eCheck DIP switch positions after cabinet maintenance.\u003c\/li\u003e\n\u003cli\u003eRecord functional test results for safety-related applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways use the manufacturer's configuration table for DIP switch assignments. Do not change safety-related settings without reviewing the approved application design.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Mechanical and Environmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Type\u003c\/td\u003e\n\u003ctd\u003eB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e20 × 119 × 115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Indicators\u003c\/td\u003e\n\u003ctd\u003eLEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Elements\u003c\/td\u003e\n\u003ctd\u003eDIP Switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe IP20 housing suits protected industrial control cabinets. It does not provide protection against water or conductive dust.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Certifications and Regulatory Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification Item\u003c\/th\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEU-Type Examination Certificate\u003c\/td\u003e\n\u003ctd\u003eZELM 00 ATEX 0024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Protection Marking\u003c\/td\u003e\n\u003ctd\u003eII (1)G [Ex ia Ga] IIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDust Protection Marking\u003c\/td\u003e\n\u003ctd\u003eII (1)D [Ex ia Da] IIIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMining Protection Marking\u003c\/td\u003e\n\u003ctd\u003eI (M1) [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Directive\u003c\/td\u003e\n\u003ctd\u003e2014\/30\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Standard\u003c\/td\u003e\n\u003ctd\u003eEN 61326-1:2013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Recommendation\u003c\/td\u003e\n\u003ctd\u003eNE 21:2006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 60529:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Safety\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCheck the current certificate documentation before hazardous-area installation. Confirm the approved application, gas group, and installation conditions.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/KFD2-SL2-Ex2.png?v=1795147237\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":68111339126966,"sku":"KFD2-SL2-Ex2","price":79.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/KFD2-SL2-Ex2-1.jpg?v=1795147237","url":"https:\/\/www.plcsparehub.com\/products\/kfd2-sl2-ex2-pepperl-fuchs-dual-channel-barrier-kfd2-series","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}