{"product_id":"kfd2-sl2-ex1-lk-pepperl-fuchs-solenoid-driver-atex-safe-output-module","title":"KFD2-SL2-Ex1.LK Pepperl+Fuchs Solenoid Driver | ATEX Safe Output Module","description":"\u003ch3\u003e\u003cstrong\u003e1. Product Overview | Intrinsically Safe Solenoid Actuation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0070c0;\"\u003eKFD2-SL2-Ex1.LK\u003c\/span\u003e\u003c\/strong\u003e from \u003cstrong\u003ePepperl+Fuchs\u003c\/strong\u003e is a single-channel isolated solenoid driver for industrial process control and hazardous-area applications.\u003c\/p\u003e\n\u003cp\u003eThis K-System interface transfers digital control signals from safe-area controllers to intrinsically safe field loads. It drives compatible solenoid valves and other approved field actuators with an output of up to \u003cstrong\u003e45 mA at a minimum of 11.2 V DC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe module accepts non-polarized logic inputs and supports line fault detection. A separate fault relay provides diagnostic signaling to the control system.\u003c\/p\u003e\n\u003cp\u003eIts design combines intrinsically safe output protection, configurable operating logic, and SIL 2 functional safety suitability. Engineers can install the module on a standard 35 mm DIN rail.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCore Engineering Functions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOne intrinsically safe digital output channel.\u003c\/li\u003e\n\u003cli\u003eNon-polarized control-side logic input.\u003c\/li\u003e\n\u003cli\u003e45 mA maximum output current.\u003c\/li\u003e\n\u003cli\u003eMinimum output voltage of 11.2 V DC.\u003c\/li\u003e\n\u003cli\u003eOpen-circuit and short-circuit monitoring.\u003c\/li\u003e\n\u003cli\u003eSeparate fault indication relay.\u003c\/li\u003e\n\u003cli\u003eSIL 2 suitability according to IEC 61508.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e2. Product Identification and Functional Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eKFD2-SL2-Ex1.LK\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK-System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid Driver \/ Isolated Barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField-Side Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntrinsically Safe Solenoid Actuation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl-Side Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-Polarized Logic Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostic Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine Fault Detection and Fault Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e3. Electrical Supply and Control-Side Input\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module receives operating power through Power Rail or dedicated supply terminals. The control-side input accepts standard DC logic signals.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Rail or Terminals 14+, 15-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Power Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 W at 45 mA output current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Input Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7, 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Polarity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-Polarized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic 0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eControl Interface Note:\u003c\/strong\u003e The input requires a valid DC logic level. Check the controller output voltage and available drive current before connecting terminals 7 and 8.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e4. Intrinsically Safe Output and Solenoid Drive Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe field-side output supplies the energy required to operate compatible intrinsically safe loads. Its electrical limits determine actuator selection and field-circuit design.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Channel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1+, 2- or 3-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e270 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.2 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Open-Circuit Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnergizing Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDe-energizing Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntrinsically Safe Ex ia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Selection:\u003c\/strong\u003e Confirm the solenoid's pickup voltage, holding current, coil resistance, and minimum operating power. The field load must remain within the driver's electrical output limits.\u003c\/p\u003e\n\u003cp\u003eDo not select an actuator using current rating alone. Its voltage requirement and intrinsic safety parameters also determine compatibility.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e5. Line Fault Detection and Diagnostic Relay\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eKFD2-SL2-Ex1.LK\u003c\/strong\u003e monitors the field output circuit for wiring abnormalities. This function helps maintenance teams distinguish load-circuit faults from normal operating conditions.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRB below 50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLead-Break Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRB above 10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLFD Test Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBelow 650 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFault Output Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, 11, 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFault Output Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Energizing Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay De-energizing Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Relay Contact Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e253 V AC \/ 2 A at cos φ greater than 0.7.\u003c\/li\u003e\n\u003cli\u003e40 V DC \/ 2 A with resistive load.\u003c\/li\u003e\n\u003cli\u003eMechanical service life: 2 × 10\u003csup\u003e7\u003c\/sup\u003e switching cycles.\u003c\/li\u003e\n\u003cli\u003eThe fault relay output is non-intrinsically safe.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Note:\u003c\/strong\u003e The LFD circuit uses a low test current. Verify the connected actuator and field wiring arrangement against the manufacturer's documentation. Do not assume that every solenoid load supports identical fault-detection behavior.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e6. Galvanic Isolation and Electrical Separation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput \/ Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic insulation according to IEC\/EN 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput \/ Supply Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput I \/ Output II\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReinforced insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput I \/ Output II Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput II \/ Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReinforced insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput II \/ Supply Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput I \/ Other Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafe electrical isolation according to IEC\/EN 60079-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Isolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e375 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese insulation specifications define the electrical separation between functional circuits. Maintain the specified wiring separation during panel installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e7. Hazardous-Area Certifications and Safety Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module supports intrinsically safe field output applications in hazardous gas, dust, and mining environments. Its approval data includes ATEX, IECEx, and CSA references.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX Examination Certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZELM 99 ATEX 0015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX Gas Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII (1)G [Ex ia Ga] IIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX Dust Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII (1)D [Ex ia Da] IIIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMining Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI (M1) [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEx ia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output Voltage Uo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output Current Io\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output Power Po\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e770 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX Certificate for Output II\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTÜV 02 ATEX 1820 X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput II Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII 3G Ex nA nC IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIECEx Certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIECEx ZLM 14.0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIECEx Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl Drawing 116-0362\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Safe Voltage Limits:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower supply Um: 40 V.\u003c\/li\u003e\n\u003cli\u003eControl input Um: 60 V.\u003c\/li\u003e\n\u003cli\u003eCollective fault message Um: 40 V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Safety Distinction:\u003c\/strong\u003e The 28 V Uo, 110 mA Io, and 770 mW Po values describe the intrinsic safety output parameters. They do not represent the normal solenoid operating voltage and current. The normal output specifications remain 11.2 V minimum and 45 mA maximum.\u003c\/p\u003e\n\u003cp\u003eAlways check the current certificate, control drawing, entity parameters, and installation conditions before connecting hazardous-area equipment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e8. Mechanical Design and Environmental Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 °C (-4 to +140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 × 119 × 115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 60715:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/KFD2-SL2-Ex1.LK.png?v=1795147111\"\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":68111321399478,"sku":"KFD2-SL2-Ex1.LK","price":97.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/KFD2-SL2-Ex1.LK-1.jpg?v=1795147111","url":"https:\/\/www.plcsparehub.com\/products\/kfd2-sl2-ex1-lk-pepperl-fuchs-solenoid-driver-atex-safe-output-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}