{"product_id":"kfa6-sr2-ex1-w-pepperl-fuchs-1-channel-namur-relay-barrier","title":"KFA6-SR2-Ex1.W Pepperl+Fuchs 1-Channel NAMUR Relay Barrier","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0066cc;\"\u003ePepperl+Fuchs KFA6-SR2-Ex1.W\u003c\/span\u003e\u003c\/strong\u003e is a \u003cstrong\u003e1-channel isolated switch amplifier\u003c\/strong\u003e for industrial signal transmission. It connects NAMUR sensors or dry contacts to control systems through a relay output.\u003c\/p\u003e\n\u003cp\u003eThe module operates with a \u003cstrong\u003e230 V AC supply\u003c\/strong\u003e and provides galvanic isolation between the field input, control output, and power supply. Its integrated \u003cstrong\u003eLine Fault Detection (LFD)\u003c\/strong\u003e identifies open circuits and short circuits in the field wiring.\u003c\/p\u003e\n\u003cp\u003eThe amplifier supports reversible operating modes. Engineers can configure the switching behavior to match the required control logic. Its safety characteristics support applications up to \u003cstrong\u003eSIL 2\u003c\/strong\u003e under IEC\/EN 61508 and IEC\/EN 61511.\u003c\/p\u003e\n\u003cp\u003eThe KFA6-SR2-Ex1.W suits industrial automation systems that require reliable NAMUR signal evaluation and isolated relay switching.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Pepperl+Fuchs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KFA6-SR2-Ex1.W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 1-channel isolated switch amplifier\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput:\u003c\/strong\u003e NAMUR sensor or dry contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e Electromechanical relay contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Monitoring:\u003c\/strong\u003e Integrated Line Fault Detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Mode:\u003c\/strong\u003e Reversible switching behavior\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e Up to SIL 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35 mm DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Reinforced galvanic isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKFA6-SR2-Ex1.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSwitch Amplifier \/ Isolated Barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eSIL 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Compatibility\u003c\/td\u003e\n\u003ctd\u003eNAMUR Sensors \/ Dry Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Terminals\u003c\/td\u003e\n\u003ctd\u003e1+, 2+, 3-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003eApproximately 8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Current\u003c\/td\u003e\n\u003ctd\u003eApproximately 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Point\u003c\/td\u003e\n\u003ctd\u003e1.2–2.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Hysteresis\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFD – Line Breakage\u003c\/td\u003e\n\u003ctd\u003eCurrent ≤ 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFD – Short Circuit\u003c\/td\u003e\n\u003ctd\u003eCurrent \u0026gt; 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Pulse Duration\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Pause Duration\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eRelay Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Terminals\u003c\/td\u003e\n\u003ctd\u003e7, 8, 9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switching Frequency\u003c\/td\u003e\n\u003ctd\u003eLess than 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Delay\u003c\/td\u003e\n\u003ctd\u003eApproximately 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelease Delay\u003c\/td\u003e\n\u003ctd\u003eApproximately 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Service Life\u003c\/td\u003e\n\u003ctd\u003e10⁷ switching cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Rating\u003c\/td\u003e\n\u003ctd\u003e253 V AC \/ 2 A, cos φ \u0026gt; 0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Rating\u003c\/td\u003e\n\u003ctd\u003e126.5 V AC \/ 4 A, cos φ \u0026gt; 0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Contact Rating\u003c\/td\u003e\n\u003ctd\u003e40 V DC \/ 2 A, resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Terminals\u003c\/td\u003e\n\u003ctd\u003e14, 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e207–253 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Frequency\u003c\/td\u003e\n\u003ctd\u003e45–65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMaximum 1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\/Output Isolation\u003c\/td\u003e\n\u003ctd\u003eReinforced insulation, 300 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\/Supply Isolation\u003c\/td\u003e\n\u003ctd\u003eReinforced insulation, 300 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\/Supply Isolation\u003c\/td\u003e\n\u003ctd\u003eReinforced insulation, 300 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Type\u003c\/td\u003e\n\u003ctd\u003eB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e20 × 119 × 115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN Rail, EN 60715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eSignal Characteristics and Functional Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. NAMUR Input Evaluation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe input follows EN 60947-5-6.\u003c\/li\u003e\n\u003cli\u003eThe module evaluates current changes from NAMUR sensors.\u003c\/li\u003e\n\u003cli\u003eThe switching threshold ranges from 1.2 to 2.1 mA.\u003c\/li\u003e\n\u003cli\u003eApproximately 0.2 mA hysteresis helps prevent unstable switching.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e2. Line Fault Detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe module monitors the field circuit for wiring faults.\u003c\/li\u003e\n\u003cli\u003eCurrent at or below 0.1 mA indicates a line break.\u003c\/li\u003e\n\u003cli\u003eCurrent above 6 mA indicates a short circuit.\u003c\/li\u003e\n\u003cli\u003eThese thresholds help maintenance teams identify field wiring problems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3. Relay Switching Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe relay provides isolated contact switching.\u003c\/li\u003e\n\u003cli\u003eOperate and release delays are approximately 20 ms.\u003c\/li\u003e\n\u003cli\u003eThe maximum switching frequency is below 10 Hz.\u003c\/li\u003e\n\u003cli\u003eMechanical life reaches 10 million switching cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e4. Electrical Isolation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReinforced insulation separates input, output, and power circuits.\u003c\/li\u003e\n\u003cli\u003eThe rated insulation voltage is 300 Veff.\u003c\/li\u003e\n\u003cli\u003eThis arrangement reduces direct electrical coupling between circuit sections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The manufacturer does not specify measurement accuracy, linearity, resolution, or analog frequency response for this digital switching device. These parameters do not apply to its intended signal evaluation function.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. DIN Rail Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the \u003cstrong\u003eKFA6-SR2-Ex1.W\u003c\/strong\u003e on a 35 mm DIN rail.\u003c\/li\u003e\n\u003cli\u003eChoose a cabinet location with suitable ventilation.\u003c\/li\u003e\n\u003cli\u003eMaintain the required clearance for wiring and maintenance.\u003c\/li\u003e\n\u003cli\u003eCheck the operating temperature range before installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e2. Electrical Connections\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal\u003c\/th\u003e\n\u003cth\u003eConnection Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1+, 2+, 3-\u003c\/td\u003e\n\u003ctd\u003eField-side sensor input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7, 8, 9\u003c\/td\u003e\n\u003ctd\u003eControl-side relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14, 15\u003c\/td\u003e\n\u003ctd\u003eAC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the NAMUR sensor or dry contact to the field terminals.\u003c\/li\u003e\n\u003cli\u003eConnect the relay contacts to the receiving control circuit.\u003c\/li\u003e\n\u003cli\u003eApply a supply voltage between 207 and 253 V AC.\u003c\/li\u003e\n\u003cli\u003eVerify terminal assignments before energizing the module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3. Hazardous Area Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse the module as an associated apparatus for intrinsically safe circuits.\u003c\/li\u003e\n\u003cli\u003eFollow the approved hazardous-area installation drawings.\u003c\/li\u003e\n\u003cli\u003eVerify sensor entity parameters against the barrier output parameters.\u003c\/li\u003e\n\u003cli\u003eCheck cable capacitance and inductance against the applicable certification limits.\u003c\/li\u003e\n\u003cli\u003eUse qualified personnel for hazardous-area wiring and inspection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHazardous Area Certification and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEU-Type Examination Certificate\u003c\/td\u003e\n\u003ctd\u003ePTB 00 ATEX 2081\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Protection Marking\u003c\/td\u003e\n\u003ctd\u003eII (1)G [Ex ia Ga] IIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDust Protection Marking\u003c\/td\u003e\n\u003ctd\u003eII (1)D [Ex ia Da] IIIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMining Protection Marking\u003c\/td\u003e\n\u003ctd\u003eI (M1) [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety Protection\u003c\/td\u003e\n\u003ctd\u003eEx ia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Voltage Uo\u003c\/td\u003e\n\u003ctd\u003e10.6 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current Io\u003c\/td\u003e\n\u003ctd\u003e19.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Power Po\u003c\/td\u003e\n\u003ctd\u003e51 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Safe Supply Voltage Um\u003c\/td\u003e\n\u003ctd\u003e253 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Directive\u003c\/td\u003e\n\u003ctd\u003e2014\/30\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Voltage Directive\u003c\/td\u003e\n\u003ctd\u003e2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Standard\u003c\/td\u003e\n\u003ctd\u003eEN 61326-1:2013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety Standard\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNAMUR Input Standard\u003c\/td\u003e\n\u003ctd\u003eEN 60947-5-6:2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Recommendation\u003c\/td\u003e\n\u003ctd\u003eNE 21:2006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 60529:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Safety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61508 and IEC\/EN 61511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Safety Information:\u003c\/strong\u003e The SIL 2 capability applies to the specified safety function and its assessed operating conditions. Verify the safety manual, failure data, proof-test requirements, and system architecture before use in a safety instrumented function.\u003c\/p\u003e\n\u003cp\u003eThe Um value represents the maximum safe voltage. It does not represent the normal rated supply voltage.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/KFA6-SR2-Ex1.W.png?v=1795145647\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":68111209332918,"sku":"KFA6-SR2-Ex1.W","price":104.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/KFA6-SR2-Ex1.W-1_bc7ac695-1ef2-49ab-b82f-d5bc4a31ff04.jpg?v=1795145647","url":"https:\/\/www.plcsparehub.com\/products\/kfa6-sr2-ex1-w-pepperl-fuchs-1-channel-namur-relay-barrier","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}