{"product_id":"is200tbcih1bbc-ge-contact-input-board-mark-vi-terminal","title":"IS200TBCIH1BBC GE Contact Input Board | Mark VI Terminal","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe General Electric \u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eIS200TBCIH1BBC\u003c\/strong\u003e\u003c\/span\u003e operates as a high-density contact input terminal board within premium automation environments. This robust printed circuit board acts as the primary physical termination interface for critical turbine supervision networks. It functions natively within the legacy \u003cspan style=\"color: #0000ff;\"\u003e\u003cstrong\u003eMark VI\u003c\/strong\u003e\u003c\/span\u003e control system lineup. The module also extends operational utility into modern Mark VIe control migration setups. It accepts field discrete signals and routes clean digital telemetry directly to VME rack processing architectures. By anchoring field-level safety loops, this card ensures continuous monitoring of high-speed industrial turbine operations.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eIS200TBCIH1BBC\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand Manufacturer:\u003c\/strong\u003e General Electric (GE)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControl Series:\u003c\/strong\u003e \u003cspan style=\"color: #0000ff;\"\u003e\u003cstrong\u003eMark VI\u003c\/strong\u003e\u003c\/span\u003e \/ Mark VIe Subsystems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Classification:\u003c\/strong\u003e Contact Input Terminal Board\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Channel Capacity:\u003c\/strong\u003e 24 discrete dry contact inputs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Block Configuration:\u003c\/strong\u003e Two heavy-duty black barrier strips housing 48 total silver metal screw terminals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExcitation Voltage Inlets:\u003c\/strong\u003e Dual 3-port white plugs labeled JE1 and JE2 for dedicated external DC power routing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHardware Interconnects:\u003c\/strong\u003e Three silver-and-black jack connectors supporting molded cable plugs or localized I\/O packs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuppression Hardware Array:\u003c\/strong\u003e 25 inline circular red noise-attenuation capacitors aligned alongside the barrier blocks\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature Limits:\u003c\/strong\u003e Performance certified from -30 to +65 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhysical Dimensions:\u003c\/strong\u003e Measures 33.02 cm height by 10.16 cm width\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Redundancy Support:\u003c\/strong\u003e Configurable for simplex, dual, or full Triple Modular Redundant structural layouts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturing Origin:\u003c\/strong\u003e Manufactured in the United States of America\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEquipment Suitability \u0026amp; Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eIS200TBCIH1BBC\u003c\/strong\u003e\u003c\/span\u003e serves as an essential termination layer for heavy industrial rotating machinery. It interfaces perfectly with GE frame-size gas turbines and utility-scale steam turbine power generation assemblies. Engineers deploy this card inside main generator control panels. It monitors limit switches, breaker aux contacts, and trip-lever statuses. The board links field sensors directly with VCCC or VCRC processor boards. These processor boards reside inside the central VME control racks.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostics \u0026amp; Protective Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Frequency Noise Suppression:\u003c\/strong\u003e Employs twenty-five dedicated red capacitors to filter line-side electromagnetic interference from field contacts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTransient Voltage Safeguards:\u003c\/strong\u003e Incorporates onboard surge protection circuitry to shield internal processing logic from external spikes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundancy Verification:\u003c\/strong\u003e Provides structural path testing across JR1, JR2, and JR3 jacks to verify multi-channel telemetry tracking.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocalized Logic Monitoring:\u003c\/strong\u003e Features independent integrated circuits adjacent to connector ports for point-of-termination signal processing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFrom an execution standpoint, the \u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eIS200TBCIH1BBC\u003c\/strong\u003e\u003c\/span\u003e board highlights the excellent hardware reliability typical of GE design philosophy. Moving the dry contact excitation voltage through independent JE1 and JE2 plugs isolates field ground faults from logic controllers. The heavy barrier terminal blocks provide reliable mechanical bite. This configuration avoids wire pull-out risks common with standard pluggable terminal modules. For facilities running TMR setups, this card provides reliable hardware voter paths. It successfully prevents single-point component failures from causing accidental turbine trips.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eShipping, Warranty, \u0026amp; Commercial Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHardware Condition:\u003c\/strong\u003e Available strictly as brand-new, unused factory-original surplus with pristine termination traces.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty Protection:\u003c\/strong\u003e Backed by an extensive 12-month all-inclusive commercial replacement warranty.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlobal Logistics:\u003c\/strong\u003e Dispatched via tier-one express logistics carriers, including FedEx, UPS, and DHL.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrder Processing Speed:\u003c\/strong\u003e Stocked units clear processing for global transit within 24-48 hours of order confirmation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage Preservation:\u003c\/strong\u003e Packaged in static-shielding bags inside secure containers to protect delicate onboard capacitors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this terminal board adapt between Simplex and Triple Modular Redundant system architectures?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSimplex systems utilize only the JR1 connector path, whereas TMR configurations employ all three connectors simultaneously to distribute signals.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat specific field contact types are compatible with the terminal inputs on this board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe inputs accept 24 dry field contacts, which require external DC excitation power routed via the JE1 and JE2 inlets.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat step is necessary when installing this module into a newer system environment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTechnicians mounting the board onto side brackets must connect Ethernet lines and initiate a firmware download to ensure compatibility.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow do the integrated circuits positioned near the jack connectors assist with maintenance diagnostics?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese specialized components handle local trace logic processing, allowing the main controller to quickly identify channel communication faults.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan field wiring be managed on this card without upgrading the existing termination infrastructure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 48 barrier-type screw terminals accommodate standard ring or spade lugs directly without external conversion blocks.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProcurement \u0026amp; Selection Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eMake sure the bill of materials calls for \u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eIS200TBCIH1BBC\u003c\/strong\u003e\u003c\/span\u003e to avoid firmware mismatches when identifying a replacement module. Verify that your enclosure space accommodates the physical profile of 33.02 cm by 10.16 cm perfectly. Label all field wiring tracks from 1 to 48 prior to removing the faulty board. Ensure your DC excitation source matches the exact voltage parameters specified in your primary turbine control manual before energizing the new assembly.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45244436185270,"sku":"IS200TBCIH1BBC","price":396.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IS200TBCIH1BBC.jpg?v=1783410325","url":"https:\/\/www.plcsparehub.com\/products\/is200tbcih1bbc-ge-contact-input-board-mark-vi-terminal","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}